AMS Trex Device Communicator Control Drawings

10
AMS Trex Device Communicator Control Drawings See the AMS Trex Device Communicator website at http:// www.emerson.com/Trex to view the latest full-size control drawings. 1 Keine Änderung ohne Prüfung durch Prüfstelle (z.B. UL, FM, CSA)! No changes prior to Certification Body approval (e.g. UL , F M, CS A)! WARNING - DO NOT USE THE USB CONNECT OR IN HAZARDOUS LOCATIONS - NE JAMAIS U TILISIER LE CONNECTEUR USB DANS DES ZONES À RISQUE D‘EXPLOSION A VERTISSEMEN T WARNING - INSTALL, CHARGE, OR R EMOVE THE POWER MO DULE ONLY IN A NONHAZARDOUS LOCATIONS - L INSTALLA TION, L E CHARGEMENTA INSI QU EL E NLÈVEMENT D U MODULE D ALIMENTATION EST POSSIBL E AVERTISSEMENT ' ' ' UNIQUEMENT EN DEHORS DES ZONES À RISQU E D EXPLOSION ' WARNING - ADDITION OR SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY - L AJOUT OU LA SUBSTITUTION DE COMPOSANTS PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÈQUE AVERTISSEMENT ' WARNING - BEFORE CONNECTING FFpwr; DISCONNECT ALL FURTHER POWER SUPPLIES AND TERMINATORS - AVANT DE CONNECTER Ffpwr, DÉCONNECTER DABORD TOUTES LES ALIMENTATIONS ET LES DISPOSITIFS DE TERMINAISON AVERTISSEMENT ' WARNING - CONNECT THE TREX DEVICE COMMUNICATOR ACCORDING TO THE SCHEMES IN THIS CONTROL DRAWING - RACCORDER CET APPAREIL TREX DEVICE CONNUNICATOR SELON LE PLAN FOURNI AVERTISSEMENT WA RNING S Trex Device Communicator Control Drawing Trex Device Communicator communication module: -HART - FOUNDA TION fieldbus (FISCO and non-FISCO ) Trex Device Communicator Plus communication module: -HAR T -mAMeter -FOUNDATION fieldbus ( FISCO and non-FISCO) WARNINGS: AT EX / IECEx :I I 2G (1GD) Ex ia [ia Ga] [ia Da IIIC ] IIC T4 Gb cCSA us: Class I, Division 1, Groups A, B, C and D, T4 Class I, Zone 1, AEx ia [ia Ga] [ia Da IIIC ] IIC T4 Gb CSA: Ex ia [ia Ga] [ia Da IIIC] IIC T4 Gb Modification/Name 1 2 3 4 Date Date Name Drawing-Number Page Pages checked issued checked 1 2 3 4 5 6 7 Alle Rechte vorbehalten! Diese Zeichnung darf ohne unsere ausdrückliche Zustimmung weder vervielfältigt, noch Dritte zugänglich gemacht werden. Außerdem darf sie durch den Empfänger oder durch Dritte nicht in anderer Art und Weise missbräuchlich verwertet werden. 2016 19 50 0 Trex Device Communicator IS Installation Drawing R. ST AHL HMI Systems GmbH Adolf-Grimme-Allee 8 D- 50829 Köln (Cologne), Germany TEL: +49 (0)221-76806-1000 FAX: +49 (0)221-76806-4100 15 10.06.2016 Wn 10.06.2016 Due 2

Transcript of AMS Trex Device Communicator Control Drawings

Page 1: AMS Trex Device Communicator Control Drawings

AMS Trex Device Communicator Control Drawings

See the AMS Trex Device Communicator website at http://www.emerson.com/Trex to view the latest full-size control drawings.

1K

eine Änderung ohne P

rüfung durch Prüfstelle

(z.B.U

L,F

M,C

SA

)!N

o ch

ang

es p

rior to

Ce

rti�catio

n B

od

y app

roval

(e.g

.U

L,

FM

,C

SA

)!

WA

RN

ING

-D

ON

OT

US

ET

HE

US

BC

ON

NE

CT

OR

INH

AZ

AR

DO

US

LO

CA

TIO

NS

-N

EJA

MA

ISU

TIL

ISIE

RL

EC

ON

NE

CT

EU

RU

SB

DA

NS

DE

SZ

ON

ES

ÀR

ISQ

UE

D‘E

XP

LO

SIO

NA

VE

RT

ISS

EM

EN

T

WA

RN

ING

-IN

STA

LL,C

HA

RG

E,O

RR

EM

OV

ET

HE

PO

WE

RM

OD

UL

EO

NLY

INA

NO

NH

AZ

AR

DO

US

LO

CA

TIO

NS

- LIN

STA

LL

AT

ION

,LE

CH

AR

GE

ME

NTA

INS

IQ

UE

LE

NL

ÈV

EM

EN

TD

UM

OD

UL

ED

AL

IME

NTA

TIO

NE

ST

PO

SS

IBL

EA

VE

RT

ISS

EM

EN

T'

''

UN

IQU

EM

EN

TE

ND

EH

OR

SD

ES

ZO

NE

RIS

QU

ED

EX

PL

OS

ION

'

WA

RN

ING

-AD

DIT

ION

OR

SU

BS

TIT

UT

ION

OF

CO

MP

ON

EN

TS

MA

YIM

PA

IRIN

TR

INS

ICS

AF

ET

Y- L

AJO

UT

OU

LA

SU

BS

TIT

UT

ION

DE

CO

MP

OS

AN

TS

PE

UT

CO

MP

RO

ME

TT

RE

LA

CU

RIT

ÉIN

TR

INS

ÈQ

UE

AV

ER

TIS

SE

ME

NT

'

WA

RN

ING

-B

EF

OR

EC

ON

NE

CT

ING

FF

pwr;D

ISC

ON

NE

CT

AL

LF

UR

TH

ER

PO

WE

RS

UP

PL

IES

AN

DT

ER

MIN

AT

OR

S-

AV

AN

TD

EC

ON

NE

CT

ER

Ffpw

r,DÉ

CO

NN

EC

TE

RD

AB

OR

DT

OU

TE

SL

ES

AL

IME

NTA

TIO

NS

ET

LE

SD

ISP

OS

ITIF

SD

ET

ER

MIN

AIS

ON

AV

ER

TIS

SE

ME

NT

'

WA

RN

ING

-C

ON

NE

CT

TH

ET

RE

XD

EV

ICE

CO

MM

UN

ICA

TO

RA

CC

OR

DIN

GT

OT

HE

SC

HE

ME

SIN

TH

ISC

ON

TR

OL

DR

AW

ING

-R

AC

CO

RD

ER

CE

TA

PP

AR

EIL

TR

EX

DE

VIC

EC

ON

NU

NIC

AT

OR

SE

LO

NL

EP

LA

NF

OU

RN

IA

VE

RT

ISS

EM

EN

T

WA

RN

ING

S

Trex Device C

omm

unicatorC

ontrol Draw

ing

Trex Device C

omm

unicator comm

unication module:

-HA

RT

-FO

UN

DA

TIO

Nfieldbus (F

ISC

Oand non-F

ISC

O)

Trex Device C

omm

unicator Plus com

munication m

odule:-H

AR

T-m

AM

eter-F

OU

ND

AT

ION

fieldbus (FIS

CO

and non-FIS

CO

)

WA

RN

ING

S:

AT

EX

/IEC

Ex:II2G

(1GD

) Ex ia [ia G

a] [ia Da

IIIC]IIC

T4 G

bcC

SA

us: Class I, D

ivision 1, Groups

A, B

, C and D

,T4

Class I, Z

one 1,AE

x ia [ia Ga] [ia D

aIIIC

]IICT

4 Gb

CS

A: E

x ia [ia Ga] [ia D

aIIIC

]IICT

4 GbM

odification/Nam

e

1234

Date

Date

Nam

eD

rawing-N

umber

Page

Pages

checkedissued

checked

12

34

56

7

Alle Rechte vorbehalten! Diese Zeichnung darf ohne unsere ausdrückliche Zustimmungweder vervielfältigt, noch Dritte zugänglich gemacht werden. Außerdem darf sie durch denEmpfänger oder durch Dritte nicht in anderer Art und Weise missbräuchlich verwertet werden.

2016 19 50 0

Trex Device C

omm

unicatorIS

Installation Draw

ingR

.S

TA

HL

HM

ISyste

ms G

mb

HA

dolf-Grim

me-A

llee 8D

- 50829 Köln (C

ologne), Germ

anyT

EL: +49 (0)221-76806-1000

FA

X: +49 (0)221-76806-4100

1510.06.2016 W

n10.06.2016 D

ue

2

Page 2: AMS Trex Device Communicator Control Drawings

Inp

ut Param

eter

Ui (V

max) = 30 V

dcIi (Im

ax) = 200 mA

Ci = 0 uF

Vt or Voc of loop m

ust be <= 30 Vdc

It or Isc of loop must be <= 200 m

A

Device does not add inductance to the loop

TAB

LE1 -

CS

AE

NT

ITY

PA

RA

ME

TE

RS

forH

AR

Tw

ithTrex D

evice Com

municator com

munication m

odule

Unclassified

Area

HA

RT

Connection

Terminals

Pow

erS

upply

HA

RT

Field Device

Trex Device C

omm

unicatorcom

munication m

odule

Unclassified

Area

Approved

Barrier or

Converter,

see Note 4

Pow

erS

upply

HA

RT

Field Device

+-

V

Device does not add capacitance to the loop

Li = 0 mH

Pi (P

max) = 1 W

Hazardous C

lassifiedA

rea

Hazardous C

lassifiedA

rea

Ou

tpu

t Parameter

Uo (Voc) = 1.89 V

dcIo (Isc) = 32 µAP

o = 61 µWC

a = 14.3 uFLa = 100 m

H

Approved

Barrier or

Converter,

see Note 4

Classification:

T4

Max.A

mbient tem

p:

HA

RT

Connection

Terminals

Trex Device C

omm

unicatorcom

munication m

odule

Current I/O

Voltage I/O

ZO

NE

1,IIC,T4

Class I, D

ivision 1,G

roupsA

, B, C

and D

ZO

NE

1,IIC,T4

Class I, D

ivision 1,G

roupsA

, B, C

and D

See Security

Ad

vice on

Page 14

Lire le avertissemen

t de sécu

rité14

sur la p

age

for device classification,see separate approvalof device

for device classification,see seperate approvalof device

12

34

56

78

910

Alle Rechte vorbehalten! Diese Zeichnung darf ohne unsere ausdrückliche Zustimmungweder vervielfältigt, noch Dritte zugänglich gemacht werden. Außerdem darf sie durch denEmpfänger oder durch Dritte nicht in anderer Art und Weise missbräuchlich verwertet werden.

Date

Date

Nam

eD

rawing-N

umber

Page

Pages

checkedissued

checked

2K

eine Änderung ohne P

rüfung durch Prüfstelle

(z.B.U

L,FM

,CS

A)!

No

chan

ges p

rior to

Certi�catio

n B

od

y app

roval

(e.g.

UL

,FM

,C

SA

)!

1234

Modification/N

ame

Connection draw

ing forH

AR

Tw

ithTrex D

evice Com

municator

comm

unication module

-20°CTa +50°C

<<

2016 19 50 0

Trex Device C

omm

unicatorIS

Installation Draw

ingR.

STA

HL

HM

ISystem

s Gm

bH

Adolf-G

rimm

e-Allee 8

D- 50829 K

öln (Cologne), G

ermany

TE

L: +49 (0)221-76806-1000FA

X: +49 (0)221-76806-4100

1510.06.2016 W

n

10.06.2016 Due

3

Page 3: AMS Trex Device Communicator Control Drawings

Unclassified AreaHazardous Classified Area

FOUNDATION fieldbusConnection Terminals

Any ApprovedAssociatedApparatus,see Note 4

MULTIPLEFOUNDATIONfieldbus DEVICES( Number islimited by therequirement tomeet all otherIS requirementsfor the network. )

Ii (Imax) = 380 mA

Ci = 0 µF

Uo (Voc) = 1.89 Vdc

Io (Isc) = 32 µA

Li = 0 mH

Pi (Pmax) = 1.3 W

Leakage current:less than or equal to 50 µA

Classification: T4

Max. Ambient temp:

Po = 61 µW

Ui (Vmax) = 30 Vdc

For Non-FISCO installation

Ca = 14.3 µF

La = 100 mH

3Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

Trex Device Communicatorcommunication module

Connection drawing for FOUNDATIONfieldbus (Non-FISCO) on theTrex Device Communicatorcommunication module

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

TABLE 2 -CSA ENTITY PARAMETERS for FOUNDATION fieldbus (Non-FISCO)with Trex Device Communicator communication module

-20°C Ta +50°C<<

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

1

2

3

4

1 2 3 4 5 6 7

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Modification/Name Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

Trex Device Communicatorcommunication module

FOUNDATION fieldbusConnection Terminals

MULTIPLEFOUNDATIONfieldbus devices(Number islimited by therequirement tomeet all otherIS and FISCOrequirementsfor the network. )

Leakage current:less than or equal to 50 µA

Classification: T4

Max. Ambient temp:

For FISCO installation

Ii (Imax) = 215 mA(IIC)380 mA(IIB)

Uo (Voc) = 1.89 Vdc

Io (Isc) = 32 µA

Pi (Pmax) = 1.9 W(IIC)/5.3W(IIB)

Po = 61 µW

Ui (Vmax) = 30 Vdc

Unclassified AreaHazardous Classified Area

4

Ci = 0 µF

Li = 0 mH

Ca = 14.3 µF

La = 100 mH

Any ApprovedFISCO Associated

Apparatus,see Note 4

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

TABLE 3 -CSA ENTITY PARAMETERS for FOUNDATION fieldbus (FISCO)with Trex Device Communicator communication module

-20°C Ta +50°C<<

See Security Advice for the FISCOconcept on Page 15

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

Lire le avertissement de sécurité15pour le concept FISCO sur la page

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

Any ApprovedFOUNDATION fieldbus

FISCO Device. See Note 5

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

1

2

3

4

1 2 3 4 5 6 7

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Modification/Name Date

Date Name Drawing-Number Page

Pagescheckedissued

checked Connection drawing for FOUNDATIONfieldbus (FISCO) withTrex Device Communicatorcommunication module

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

4

Page 4: AMS Trex Device Communicator Control Drawings

FF

FFpwr

mA HART+ pwr HART

Input Parameter

Ui (Vmax) = 30 VdcIi (Imax) = 200 mA

Ci = 0 uF

Vt or Voc of loop must be <= 30 VdcIt or Isc of loop must be <= 200 mA

Device does not add inductance to the loop

TABLE 4 - CSA ENTITY PARAMETERS for HART with Trex Device Communicator Plus communication module

Connection drawing for HART withdevice Trex Device CommunicatorPlus communication module

Unclassified Area

HARTConnectionTerminals

PowerSupply

HARTField Device

Trex Device Communicator Pluscommunication module

Unclassified Area

ApprovedBarrier orConverter,see Note 4

PowerSupply

HARTField Device

+ - V

Device does not add capacitance to the loopLi = 0 mH

Pi (Pmax) = 1 W

Hazardous Classified Area

Hazardous Classified Area

Output Parameter

Uo (Voc) = 1.89 VdcIo (Isc) = 1.9 mAPo = 3.6 mWCa = 14.3 uFLa = 100 mH

ApprovedBarrier orConverter,see Note 4

FF

FFpwr

mA HART+ pwr HART

HARTConnectionTerminals

Trex Device Communicator Pluscommunication module

Voltage I/O

Classification: T4

Max. Ambient temp:-20°C Ta +50°C<<

Current I/O

ZONE 1, IIC, T4

Class I, Division 1,Groups A, B, C and D

ZONE 1, IIC, T4

Class I, Division 1,Groups A, B, C and D

for device classification,see separate approvalof device

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

1 2 3 4 5 6 7

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

5Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

1

2

3

4

Modification/Name

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

FF

FFpwr

mA HART+ pwr HART

Input Parameter

Ui (Vmax) = 30 VdcIi (Imax) = 200 mA

Ci = 0 uF

Vt or Voc of loop must be <= 30 VdcIt or Isc of loop must be <= 200 mA

Device does not add inductance to the loop

TABLE 5 - CSA ENTITY PARAMETERS for HART pwr with Trex Device Communicator Plus communication module

HART + pwrConnectionTerminals

HARTField Device

Trex Device Communicator Pluscommunication module

Device does not add capacitance to the loopLi = 0 mH

Pi (Pmax) = 1 W

Hazardous Classified Area

Output Parameter

Uo (Voc) = 25.69 VdcIo (Isc) = 105 mAPo = 668 mWCa = * nF

La 1000 µH 750 µH 500 µH 100 µH

Classification: T4

Max. Ambient temp:

Connection drawing for HART withTrex Device Communicator Pluscommunication module and internalpower supply

-20°C Ta +50°C<<

Current I/O

Ca 57 nF 64 nF 75 nF 102 nF

* Output parameter L/C

La = * µH

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

1 2 3 4 5 6 7 8 9 10

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

6Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

1

2

3

4

Modification/Name

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

5

Page 5: AMS Trex Device Communicator Control Drawings

7Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

FF

FFpwr

mA HART+ pwr HART

Unclassified Area

mAConnectionTerminals

PowerSupply

Trex Device Communicator Pluscommunication module

Hazardous Classified Area

ApprovedBarrier orConverter,see Note 4

TABLE 6 - CSA ENTITY PARAMETERS for the mA Meter with Trex Device Communicator Plus communication module

Input Parameter

Ui (Vmax) = 30 VdcIi (Imax) = 200 mA

Ci = 0 uF

Vt or Voc of loop must be <= 30 VdcIt or Isc of loop must be <= 200 mA

Device does not add inductance to the loopDevice does not add capacitance to the loop

Li = 0 mH

Pi (Pmax) = 1 W

Output Parameter

Uo (Voc) = 0 VdcIo (Isc) = 0 mAPo = 0 mWCa = - uFLa = - mH

Classification: T4

Max. Ambient temp:-20°C Ta +50°C<<

ZONE 1, IIC, T4

Class I, Division 1,Groups A, B, C and D

HARTField Device

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

Modification/Name

1

2

3

4

Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

1 2 3 4 5 6 7 8 9 10

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Connection drawing for mA terminalson Trex Device Communicator Pluscommunication module

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

8Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

FF

FFpwr

mA HART+ pwr HART

Unclassified Area

mAConnectionTerminals

PowerSupply

Trex Device Communicator Pluscommunication module

Hazardous Classified Area

ApprovedBarrier orConverter,see Note 4

TABLE 7 - CSA ENTITY PARAMETERS for the mA Meter with Trex Device Communicator Plus communication module

Input Parameter

Ui (Vmax) = 30 VdcIi (Imax) = 200 mA

Ci = 0 uF

Vt or Voc of loop must be <= 30 VdcIt or Isc of loop must be <= 200 mA

Device does not add inductance to the loopDevice does not add capacitance to the loop

Li = 0 mH

Pi (Pmax) = 1 W

Output Parameter

Uo (Voc) = 0 VdcIo (Isc) = 0 mAPo = 0 mWCa = - uFLa = - mH

+ - test

FF

FFpwr

mA HART+ pwr HART

Unclassified Area

mAConnectionTerminals

PowerSupply

Trex Device Communicator Pluscommunication module

Hazardous Classified Area

ApprovedBarrier orConverter,see Note 4

+ - test

Classification: T4

Max. Ambient temp:-20°C Ta +50°C<<

HART Field Device(Test terminal referenced to +)

HART Field Device(Test terminal referenced to -)

ZONE 1, IIC, T4

Class I, Division 1,Groups A, B, C and D

ZONE 1, IIC, T4

Class I, Division 1,Groups A, B, C and D

for device classification,see separate approvalof device

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

Modification/Name

1

2

3

4

Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

1 2 3 4 5 6 7 8 9 10

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Connection drawing for mA terminalson the Trex Device Communicator Pluscommunication module

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

6

Page 6: AMS Trex Device Communicator Control Drawings

Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

FF

FFpwr

mA HART+ pwr HART

Unclassified Area

mAConnectionTerminals

PowerSupply

Trex Device Communicator Pluscommunication module

Hazardous Classified Area

ApprovedBarrier orConverter,see Note 4

TABLE 8 - CSA ENTITY PARAMETERS for the mA Meter with Trex Device Communicator Plus communication module

Input Parameter

Ui (Vmax) = 30 VdcIi (Imax) = 200 mA

Ci = 0 uF

Vt or Voc of loop must be <= 30 VdcIt or Isc of loop must be <= 200 mA

Device does not add inductance to the loopDevice does not add capacitance to the loop

Li = 0 mH

Pi (Pmax) = 1 W

Output Parameter

Uo (Voc) = 1.89 VdcIo (Isc) = 1.9 mAPo = 3.6 mWCa = 14.3 µFLa = 100 mH

- test

FF

FFpwr

mA HART+ pwr HART

Unclassified Area

mAConnectionTerminals

PowerSupply

Trex Device Communicator Pluscommunication module

Hazardous Classified Area

ApprovedBarrier orConverter,see Note 4

+ - test

Classification: T4

Max. Ambient temp:-20°C Ta +50°C<<

HART Field Device(referenced to -)

9

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

Connection drawing for mA terminalson the Trex Device Communicator Pluscommunication module

HARTTerminals

+

HARTTerminals

HART Field Device(referenced to +)

for device classification,see separate approvalof device

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

Modification/Name

1

2

3

4

Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

1 2 3 4 5 6 7 8 9 10

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

10Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

FF

FFpwr

mA HART+ pwr HART

Unclassified Area

mAConnectionTerminals

PowerSupply

Trex Device CommunicatorPlus communication module

Hazardous Classified Area

ApprovedBarrier orConverter,see Note 4

TABLE 9 - CSA ENTITY PARAMETERS for the mA Meter with Trex Device Communicator Plus communication module

Input Parameter

Ui (Vmax) = 30 VdcIi (Imax) = 200 mA

Ci = 0 uF

Vt or Voc of loop must be <= 30 VdcIt or Isc of loop must be <= 200 mA

Device does not add inductance to the loopDevice does not add capacitance to the loop

Li = 0 mH

Pi (Pmax) = 1 W

Output Parameter

Uo (Voc) = 1.89 VdcIo (Isc) = 1.9 mAPo = 3.6 mWCa = 14.3 µFLa = 100 mH

+ - test

Classification: T4

Max. Ambient temp:-20°C Ta +50°C<<

HARTField Device

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

Connection drawing for mA terminalson the Trex Device Communicator Pluscommunication module

HARTTerminals

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

Modification/Name

1

2

3

4

Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

1 2 3 4 5 6 7 8 9 10

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

7

Page 7: AMS Trex Device Communicator Control Drawings

FF

FFpwr

mA HART+ pwr HART

Unclassified AreaHazardous Classified Area

FOUNDATION fieldbusConnection Terminals

Any ApprovedAssociatedApparatus,see Note 4

MULTIPLEFOUNDATIONfieldbus devices(Number islimited by therequirement tomeet all otherIS requirementsfor the network. )

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

Ii (Imax) = 380 mA

Ci = 0 µF

Uo (Voc) = 1.89 Vdc

Io (Isc) = 32 µA

Li = 0 mH

Pi (Pmax) = 1.3 W

Leakage current:less than or equal to 50 µA

Classification: T4

Max. Ambient temp:

Po = 61 µW

Ui (Vmax) = 30 Vdc

For Non-FISCO installation

Ca = 14.3 µF

La = 100 mH

11Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

Trex Device Communicator Pluscommunication module

Connection drawing for FOUNDATIONFieldbus (Non-FISCO) on theTrex Device Communicator Pluscommunication module

TABLE 10 -CSA ENTITY PARAMETERS for FOUNDATION fieldbus (Non-FISCO)with Trex Device Communicator Plus communication module

-20°C Ta +50°C<<

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

1

2

3

4

1 2 3 4 5 6 7

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Modification/Name Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

FF

FFpwr

mA HART+ pwr HART

Trex Device Communicator Pluscommunication module

FOUNDATION fieldbusConnection Terminals

Leakage current:less than or equal to 50 µA

Classification: T4

Max. Ambient temp:

For FISCO installation

Ii (Imax) = 215 mA(IIC)380 mA(IIB)

Uo (Voc) = 1.89 Vdc

Io (Isc) = 32 µA

Pi (Pmax) = 1.9 W(IIC)/5.3W(IIB)

Po = 61 µW

Ui (Vmax) = 30 Vdc

Unclassified AreaHazardous Classified Area

12

Ci = 0 µF

Li = 0 mH

Ca = 14.3 µF

La = 100 mH

Any ApprovedFISCO Associated

Apparatus,see Note 4

Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

TABLE 11 -CSA ENTITY PARAMETERS for FOUNDATION fieldbus (FISCO)with Trex Device Communicator Plus communication module

-20°C Ta +50°C<<

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

MULTIPLEFOUNDATIONfieldbus devices(Number islimited by therequirement tomeet all otherIS requirementsfor the network. )

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

for device classification,see separate approvalof device

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

See Security Advice for the FISCOconcept on Page 15

Lire le avertissement de sécurité15pour le concept FISCO sur la page

1

2

3

4

1 2 3 4 5 6 7

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Modification/Name Date

Date Name Drawing-Number Page

Pagescheckedissued

checked Connection drawing for FOUNDATIONfieldbus (FISCO) with deviceTrex device communicator Pluscommunication module

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

8

Page 8: AMS Trex Device Communicator Control Drawings

FF

FFpwr

mA HART+ pwr HART

Trex Device Communicator Pluscommunication module

Hazardous Classified Area

Ci = 231 nF

Uo (Voc) = 17.31 Vdc

Io (Isc) = 199 mA

Li = 0 mH

Leakage current:less than or equal to 50 µA

Classification: T4

Max. Ambient temp:

Po = 0.94 W

Ui (Vmax) = 17.5 Vdc

For FISCO and non-FISCO installation

Ca = * nF

La = * µH

13Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

Ii (Imax) = 380 mA

Pi (Pmax) = 1.3 W

See Security Advice on Page 14

Lire le avertissement de sécurité14sur la page

1

2

3

4

1 2 3 4 5 6 7

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Modification/Name Date

Date Name Drawing-Number Page

Pagescheckedissued

checked Connection drawing for FOUNDATIONfieldbus with device Trex DeviceCommunicator Plus communicationmodule and internal power supply

TABLE 12 -CSA ENTITY PARAMETERS for FOUNDATION fieldbus with interalpower supply with Trex Device Communicator Plus communication module

FOUNDATION Fieldbus Power plug

-20°C Ta +50°C<<

La 100 µH 50 µH 30 µHCa 19 nF 69 nF 115 nF

* Output parameter L/C

ZONE 1, IIC, T4

Class I, Division 1, Groups A, B, C and D

Any ApprovedFOUNDATION fieldbus

Device. See Note 5

FOUNDATION fieldbusConnection Terminals

for device classification,see separate approvalof device

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

14Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

nonincendive Equipment Associated ApparatusEquipment non- inflammable Appareil associé

Vmax Voc or Uo>Imax Isc or Io>Pi Po>Ci + Ccable Ca (or Co)<Li + Lcable La (or Lo)<

1. No revision to drawing prior to certification body.La modification des plans n'est pas autorisée sans l'accordde l'organisme notifié.

2. The Associated Apparatus must be NRTL approved in accordanceto IEC 60079-11.Les appareils associés doivent avoir une certification NRTL selon

.IEC 60079-11

3. Manufacturer’s installation drawing must be followedwhen installing associated apparatus.Les plans d´installation des produits des appareils associés doiventêtre respectés s'ils sont installés.

4. Interconnection of nonincendive equipment apparatus withassociated apparatus is allowed when the followingis true:L'interconnexion des équipements non- inflammable est correcteuniquement si les paramètres suivants sont respectés:

WARNING:- Substitution of components may impair Safety.

AVERTISSEMENT:La substitution de composants peut compromettre la sécurité.-

1.) Determination of maximum possible capacitance of cable:

Cmax = Ca - Ci (associated Apparatus)

Determination of maximum possible inductance of cable:

Lmax = La - Li (associated Apparatus)

2.) Determination of maximum possible cable length bycapacitance and inductance of cable:

length C = CmaxCcable (*1)

length L = LmaxLcable (*1)

3.) Determination of maximum length of cable:

length C or lenght L, whatever is less.

Calculation of cable length

Security AdvicesAvertissements de sécurité

5. for ATEX / IECEx: Installation should be in accordance withANSI/ISA RP12.06.01 “Installation of Intrinsically safesystems for Hazardous (classified) Locations” andthe National Electrical Code (ANSI/NFPA 70)Pour ATEX/ IECEx : l'installation doit être conforme à la normeANSI/ISA RP12.06.01 (installation de systèmes à sécurité intrinsèquepour les emplacements dangereux (classés) et le NationalElectrical Code (ANSI/NFPA 70)

for cCSAus: Installation should be in accordance with CanadianElectrical Code, CSA 22.1, Part 1.Pour cCSAAus : l'installation doit être conforme au code canadiende l´électricité CSA 22.1 partie 1.

1

2

3

4

1 2 3 4 5 6 7

Alle

Rech

te v

orb

ehalte

n! D

iese

Zeic

hnung d

arf

ohne u

nse

re a

usd

rück

liche Z

ust

imm

ung

weder

verv

ielfä

ltigt, n

och

Dritte z

ugänglic

h g

em

ach

t w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issb

räuch

lich v

erw

ert

et w

erd

en.

Modification/Name Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

Security Advices

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

9

Page 9: AMS Trex Device Communicator Control Drawings

FISCO CONCEPT

15

THE FISCO CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TOASSOCIATED APPARATUS NOT SPECIALLY EXAMINED IN SUCH COMBINATION. THE CRITERIAFOR INTERCONNECTION IS THAT THE VOLTAGE (Ui OR Vmax), THE CURRENT (Ii OR Imax) ANDTHE POWER (Pi OR Pmax) WHICH AN INTRINSICALLY SAFE APPARATUS CAN RECEIVE AND REMAININTRINSICALLY SAFE CONSIDERING FAULTS, MUST BE EQUAL OR GREATER THAN VOLTAGE (Uo,Voc OR Vt), THE CURRENT (Io, Isc OR It) AND THE POWER (Po OR Pmax) LEVELS WHICH CANBE DELIVERED BY THE ASSOCIATED APPARATUS, CONSIDERING FAULTS AND APPLICABLEFACTORS. IN ADDITION, THE MAXIMUM UNPROTECTED CAPACITANCE (Ci) AND THE INDUCTANCE(Li) OF EACH APPARATUS (OTHER THAN THE TERMINATION) CONNECTED TO THE FIELDBUSMUST BE LESS THAN OR EQUAL TO 5 nF and 10 uH RESPECTIVELY.

IN EACH SEGMENT, ONLY ONE ACTIVE DEVICE, NORMALLY THE ASSOCIATED APPARATUS, ISALLOWED TO PROVIDE THE NECESSARY ENERGY FOR THE FIELDBUS SYSTEM. THE VOLTAGEUo (OR Voc OR Vt) OF THE ASSOCIATED APPARATUS IS LIMITED TO A RANGE OF 14 V TO24 Vdc ALL OTHER EQUIPMENT CONNECTED TO THE BUS CABLE HAS TO BE PASSIVE,MEANING THAT THEY ARE NOT ALLOWED TO PROVIDE ENERGY TO THE SYSTEM, EXCEPT ALEAKAGE CURRENT OF 50uA FOR EACH CONNECTED DEVICE. SEPARATELY POWEREDEQUIPMENT NEEDS GALVANIC ISOLATION TO ENSURE THAT THE INTRINSICALLY SAFEFIELDBUS CIRCUIT REMAINS PASSIVE.

THE CABLE USED TO INTERCONNECT DEVICES NEEDS TO HAVE THE PARAMETERS IN THEFOLLOWING RANGE:

Loop Resistance R’: 15.....150 Ohm/kmInductance per unit length L’: 0.4.....1 mH/kmCapacitance per unit length C’: 80.....200 nF/kmC’ = C’ line/line + 0.5C’ line/screen, if both lines are floating, orC’ = C’ line/line + C’ line/screen, if the screen is connected to one lineLength of trunk cable: less than or equal to 1000mLength of spur cable: less than or equal to 30mLength of spur splice: less than or equal to 1m

AT EACH END OF THE TRUNK CABLE AN APPROVED INFALLIBLE LINE TERMINATION WITH THEFOLLOWING PARAMETERS IS SUITABLE:

R = 90.....100 Ohm C = 0.....2.2 uF

ONE OF THE ALLOWED TERMINATIONS MIGHT ALREADY BE INTEGRATED IN THE ASSOCIATEDAPPARATUS. THE NUMBER OF PASSIVE APPARATUS CONNECTED TO THE BUS SEGMENT IS NOTLIMITED DUE TO I.S. REASONS. IF THE ABOVE RULES ARE RESPECTED, UP TO A TOTALLENGTH OF 1000 m (SUM OF TRUNK AND ALL SPUR CABLES) OF CABLE IS PERMITED.THE INDUCTANCE AND THE CAPACITANCE OF THE CABLE WILL NOT IMPAIR THEINTRINSIC SAFETY OF THE INSTALLATION.

Keine Änderung ohne Prüfung durch Prüfstelle(z.B. UL, FM, CSA)!

No changes prior to Certification Body approval(e.g. UL, FM, CSA)!

10.02.15 DüEPL marking for CSA added

Modification/Name

1

2

3

4

Date

Date Name Drawing-Number Page

Pagescheckedissued

checked

1 2 3 4 5 6 7 8 9 10

Alle

Rechte

vorb

ehalten! D

iese Z

eic

hnung d

arf

ohne u

nsere

ausdrü

cklic

he Z

ustim

mung

weder

verv

ielfältig

t, n

och D

ritte z

ugänglic

h g

em

acht w

erd

en.A

erd

em

darf

sie

durc

h d

en

Em

pfä

nger

oder

durc

h D

ritte n

icht in

andere

rA

rt u

nd W

eis

e m

issbrä

uchlic

h v

erw

ert

et w

erd

en.

FISCO Concept

2016 19 50 0

Trex Device CommunicatorIS Installation Drawing

R. STAHL HMI Systems GmbHAdolf-Grimme-Allee 8D- 50829 Köln (Cologne), GermanyTEL: +49 (0)221-76806-1000FAX: +49 (0)221-76806-4100

1510.06.2016 Wn

10.06.2016 Due

10

Page 10: AMS Trex Device Communicator Control Drawings