Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

38
Enhanced Cryogenic Air Separation Enhanced Cryogenic Air Separation A proven Process applied to Oxyfuel Future Prospects Dr -Ing Gerhard Beysel Future Prospects Dr . Ing. Gerhard Beysel 1 st Oxyfuel Combustion Conference Cottbus, Sept 8th, 2009

Transcript of Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Page 1: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation A proven Process applied to OxyfuelFuture Prospects

Dr -Ing Gerhard Beysel

Future Prospects

Dr. Ing. Gerhard Beysel1st Oxyfuel Combustion ConferenceCottbus, Sept 8th, 2009

Page 2: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Agenda

1 Introduction

2 Air Separation Technologies

3 Potentials for Power Savings and Cost Reduction

4 Potentials for Large Capacities and Oxygen Demand for New4 Potentials for Large Capacities and Oxygen Demand for New

Applications

5 Innovative Improvements at Cryogenic Air Separation

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 2

Page 3: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

The Linde Group The Divisions

Linde EngineeringLinde Gas

(Headquarter Munich, Germany)

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 3

( y)

50 000 employees Sales 17 billion US$2006

Page 4: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Linde Engineering DivisionProduct Lines & Key Plant TypesTypes

Olefin Plants

— Products:

Natural Gas Plants

Products: Products:— LNG— NGL— LPG— Helium

Products:— Ethylene— Propylene— Butadiene— Aromatics

— NRUAromatics

— Polymers

Air Separation PlantsHydrogen and Synthesis Gas Plants

— Products:— Oxygen

— Products:— H2/CO/Syngas Oxygen

— Nitrogen— Rare gases

H2/CO/Syngas— Ammonia— Gas removal— Gas purification

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 4

Page 5: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Carbon Capture Technologies (CCS) - From the ASU Perspective -

Technology Process Linde Portfolio

1. Pre-Combustion(IGCC)

GasifierASU

Gas cleaningCO Shift

CO2 Liquefaction

&(IGCC) er g(Rectisol) &

Compression

Feedstock

Feedstock CO2

2. Oxyfuel(Oxycoal)

DeSOxBoilerASU DeNOxCO2

Liquefaction &

Compression

CO2

3. Post-Combustion(PCC)

DeSOxBoiler DeNOx

CO2 capture &

Compression

Feedstock

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 5

(PCC) p

CO2

Page 6: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation PlantsSimplified Air Separation Process

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 6

Air compression, -precooling and -purification

heat exchange, refrigeration,rectification and internal compression

productdistribution

Page 7: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Alternative Air Separation Technologies

Cryogenic Air Separation (ASU) the principles invented one century ago (Dr. Carl von Linde) developed for large volumes of oxygen and nitrogen with high purities developed for large volumes of oxygen and nitrogen with high purities commercialized for industrial application in a wide range the source for Industrial Gas Companies supply schemes Continuous development and improvement , >25% power saving possible

Polymeric Membranes and Moleculare Sieves (PSA, VSA) advantageous for small volumes - at lower purities produced at ambient temperatures and as needed on-site

Oxygen Production by Chemical Air Separation (MOLTOX) Developed and pilot tested by Air Products with DOE funding in early 1990s >40% power saving predicted, compared with cryogenic processes Status and future of the process unknown (material- and corrossion problems)

High Temperature Ceramic Membranes (ITM) Developed and pilot testing (5t/d) since 2005 by Air Products with DOE funding

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 7

150 tpd under development; >30% power saving predicted

Page 8: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Alternative Air Separation Technologies - Potentials to Reduce Power Consumption and CostCostCryogenic Air Separation (ASU)

the principles invented one century ago (Dr. Carl von Linde) developed for large volumes of oxygen and nitrogen with high purities developed for large volumes of oxygen and nitrogen with high purities commercialized for industrial application in a wide range the source for Industrial Gas Companies supply schemes Continuous development and improvement , >25% power saving possible

High ++

Polymeric Membranes and Moleculare Sieves (PSA, VSA) advantageous for small volumes - at lower purities produced at ambient temperatures and as needed on-site

medium+

Oxygen Production by Chemical Air Separation (MOLTOX) Developed and pilot tested by Air Products with DOE funding in early 1990s >40% power saving predicted, compared with cryogenic processes

?

Status and future of the process unknown (material- and corrossion problems)

High Temperature Ceramic Membranes (ITM) Developed and pilot testing (5t/d) since 2005 by Air Products with DOE funding

High ++

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 8

150 tpd under development; >30% power saving predicted

High ++

Page 9: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Alternative Air Separation Technologies - Potentials to Supply Large Product Flows

Cryogenic Air Separation (ASU) the principles invented one century ago (Dr. Carl von Linde) developed for large volumes of oxygen and nitrogen with high purities developed for large volumes of oxygen and nitrogen with high purities commercialized for industrial application in a wide range the source for Industrial Gas Companies supply schemes Continuous development and improvement , >25% power saving possible

High ++

Polymeric Membranes and Moleculare Sieves (PSA, VSA) advantageous for small volumes - at lower purities produced at ambient temperatures and as needed on-site

low

Oxygen Production by Chemical Air Separation (MOLTOX) Developed and pilot tested by Air Products with DOE funding in early 1990s >40% power saving predicted, compared with cryogenic processes

?

Status and future of the process unknown (material- and corrossion problems)

High Temperature Ceramic Membranes (ITM) Developed and pilot testing (5t/d) since 2005 by Air Products with DOE funding

?

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 9

150 tpd under development; >30% power saving predicted

?

Page 10: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Typical Oxygen Demand for New Applications

New Applications Capacity [MW] Oxygen [tons/day ]

IGCC (demo) 250 - 300 MW - 2.000 1)

IGCC, Oxyfuel (demo) 300 - 600 MW 2.000 - 5.000 1)

CTL, Polygeneration (project) 1500 MW, yg (p j )25.000 1)

GTL (demo) 12.000 bpd 2.500 2)

GTL (commercial 35.000 bpd 7.000 2)

scale)GTL (commercial scale)

140.000 bpd 30.000 2)

Cryogenic ASUs: Single train sizes with a capacity of 5.000 tons/d are available

1) Low puity oxygen <95%

capacities < 7.000 ton/d under development

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 10

Low puity oxygen 95%2) High purity oxygen >99,5%

Page 11: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Cryogenic Air Separation – Capacity Increase

1902 : 2006 :

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 11

1902 :5 kg/h(0,1 ton/day)

2006 :1,250 Mio kg/h(30.000 ton/day)

Page 12: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Plants – Shell „Pearl“ GTL Project Qatar30 000 tons/day Oxygen30.000 tons/day Oxygen

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 12

Page 13: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Plants – Shell „Pearl“ GTL Project Qatar30 000 tons/day Oxygen30.000 tons/day Oxygen

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 13

Page 14: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Large Tonnage ASU Coldbox Shipment for „Pearl“ GTL project

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 14

Page 15: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Tonnage Air Separation PlantsMega Plants for new Applications

Cryogenic Air Separation Process OptimizationCryogenic Air Separation Process Optimization

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 15

Page 16: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Process Conventional Design (mit Einblaseturbine)

PG

AN

GO

X

-6 b

ar

ar

onne

5.5-

1.05

ba

Wär

met

ausc

her

Boo

ster

Turb

ine

ator

Nie

derd

ruck

kolo

Kon

dens

a

G

ochd

ruck

kolo

nne

UK

G

-5.8

bar

Oxygen: 95%, gaseous, at ambient pressure

Features:

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 16

Ho

5.3

PNitrogen: up to 30% of airflow available

Page 17: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Process Advanced Alternative Design(mit warmer PGAN-Turbine)(mit warmer PGAN-Turbine)

GO

X

GPOWER

Power Wärme/Abwärme

5.2-5.7 bar

PG

AN

Vorkühlung Adsorber

R t

AIR5.

5-6

bar

1.2-1.3 bar

1.05

bar

Wär

met

ausc

her

oste

r

rbin

e

1 r

Nie

derd

ruck

kolo

nneRestgas

Bo Tu

1 Kon

dens

ato

G

Oxygen: 95%, gaseous, at ambient pressure

Hoc

hdru

ckko

lonn

e

UK

G

5.3-

5.8

bar

Features:

reduced energy consumption/power recovery by expanding

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 17

5

PGAN

heat integration

Page 18: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Process Advanced Alternative Design (“Dual Reboiler”-Design)Design)

GO

X

5 ba

r

bar

derd

ruck

kolo

nne

4.5

1.05

b

Wär

met

ausc

her

Boo

ster

Turb

ine

dens

ator

2

Nie

d

UKG

Kon

d

e

U

onde

nsat

or 1

Oxygen: 95% gaseous at ambient pressure

Hoc

hdru

ckko

lonn

eKo

4.3

bar

Oxygen: 95%, gaseous, at ambient pressure

Features:

reduced process air pressure

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 18

reduced process air pressure

reduced power consumtion

Page 19: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Process Advanced Alternative Design (3-column Design)

GO

X

.5 b

ar

bar

4.

1.05

Wär

met

ausc

her

Boos

ter

Turb

ine

Kon

dens

ator

2er

druc

kkol

onne

2

UKG

Nie

de

ensat

or 1

uckk

olon

ne 1

Oxygen: 95% gaseous at ambient pressure

Hoc

hdru

ckko

lonn

e

Kond

en

4.3

bar

Nie

derd

ru Oxygen: 95%, gaseous, at ambient pressure

Features:

reduced process air pressure

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 19

reduced process air pressure

reduced power consumtion

Page 20: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation UnitsCryogenic Oxygen / Specific Energy ConsumptionConsumption

Conventional Process Schemes / - Applications

kWh/Nm³ 1) kWh/Nm³ 2) kWh/t (metric ton) 3)kWh/t (short ton)

(= 907,2 kg) 3)

Conversion Figures:

1 O,95 699 635

0,35 kWh/Nm³ O,33 kWh/Nm³ 245 kWh/t 222 kWh/t

Conventional ASU, Oxygen Purity >99.5%

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 20

1) used by ASU vendors (Linde et al) and commonly used for process calculation 2) used by Gas Companies 3) 1 Nm³ = 1,429 kg

Page 21: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation UnitsCryogenic Oxygen / Specific Energy ConsumptionConsumption

Advanced Process Schemes for New Applications, e.g. IGCC, Oxyfuel, IGSC

kWh/Nm³ 1) kWh/Nm³ 2) kWh/t (metric ton) 3)kWh/t (short ton)

(= 907,2 kg) 3)

Advanced, energy optimized ASU, 95 % Purity Oxygen

0,25 0,237 175 159

Power consumption reduced by > 25% !!

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 21

Above Figures are related to 100% Oxygen (contained Oxygen), normal ambient conditions for design: 20°C, 15°C CW, 60% rel. humidity, at sea level

Page 22: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation PlantsMega Plants for new Applications

Power Plant Specific Requirements and their consequencesp q q

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 22

Page 23: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Units for Power Plants Specific Requirements

Specific Power Plant Requirements:

lowest possible power consumption

CAPEX and OPEX optimization

operation range from 60 to 105%

load change > 2% per minute

oxygen purity 95%

low product pressure

Differences between Power Plant Standards and conventional Industrial Gases

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 23

Standards

Page 24: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Units Specific Requirements for Power Plants

If project specific requirements:If project specific requirements:

Design margin of 5%,

turndown to 63%,

design for maximum ambient conditions,

liquid production liquid production

are not to be considered for design,

potential for further power saving of 8%.

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 24

Page 25: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Units for Power PlantsAir Compression Efficiency

Impact of Turndown Requirement on Main Air Compressor EfficiencyImpact of Turndown Requirement on Main Air Compressor Efficiency(For a typical ASU)

Turndown Power at motor terminal Additional powerComparison

75 to 80% 18 500 kW 100 %

63% 19 100 kW + 600 kW 103 %

56% 19 500 kW + 1000 kW 105 %

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 25

Page 26: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Units for Power PlantsAir Compression Efficiency

Impact of Different Ambient Air TemperaturesImpact of Different Ambient Air Temperatures

Ambient Air Temperature -17°C 9°C 30°C 33°C

Effective Air Volume Flow 91% 100% 107% 109%

plus 5% design margin

plus turndown requirementplus turndown requirement

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 26

Page 27: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Load change scenario: Ramping of process parameters Target > 2%/min – fluctuation of oxygen purity? Target > 2%/min – fluctuation of oxygen purity?

Load change scenario - conventional process scheme considered ramping > 4 %/min

350000

400000

0 98

0,99

1

250000

300000

0,96

0,97

0,98 Oxygen Purity

150000

200000

Nm

³/h]

0,94

0,95

O2

[%]

Mair

MGOX

O2_%

50000

100000

0,91

0,92

0,93

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 27

00 2000 4000 6000 8000 10000 12000 14000

Time [sec]

0,9

Page 28: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Air Separation Units for Power PlantsSummary, Low Power Consumption

Steps to low power consumption of ASU:

apply highly efficient air separation process

select appropriate compressor model

identify possibilities for power/heat integration

pick advantageous driver option

check operations requirements carefully (turn down, design margin, etc.)

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 28

Page 29: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Advanced Cryogenic Air Separation - innovative improvements for new applications

Advanced Structured Packings instead of sieve tray columns available

reducing pressure drop , increasing turndown capacity

Advanced process control systems, ALC (AutomaticLoadChange)p y ( g )available

Dynamic Simulation

Compressors with higher efficiency, larger turndown range development

High efficient Heat Exchangers available

Advanced process schemes 1) available

1) Large Scale Low Purity Oxygen Requirement (e.g. 95%) - is a novalty in Cryogenic ASU applica

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 29

g y yg q ( g ) y y g pp

leads to a step change energy reduction compared to traditional applications !

Page 30: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Linde Engagement in CCS – Oxyfuel

Linde has built an air separation plant and a CO2 purification and liquefaction plant for Vattenfall’s first oxyfuel pilot plant for coal-based power generation

Linde Portfolio

with CO2 capture.

Oxyfuel Combustion

Portfolio

CO2 to Storage

H2O Condensation CO2 LiquefactionAir Separation Unit

Steam

N2 Free Flue Gas

OxygenCombustion

&Power Generation

&

CO2 Recycle

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 30

Feedstock&

Steam Generation&

Heat Recovery

Page 31: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Groundbraking Ceremony May 2006

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 31

Page 32: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Oxyfuel Pilot Plant Schwarze Pumpe –3-D Model

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 32

Page 33: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Oxyfuel Pilot Plant Schwarze PumpeOfficial Inauguration and start-up: Sept. 9th 2008

Boiler

Dust filter ASU

DSU

FGC

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 33

CO2 plant Control room

Page 34: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Vattenfall Oxyfuel Powerplant Schwarze PumpeLinde Scope: ASU, CO2 Plant; TechnologiepartnershipTechnologiepartnership

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 34

Page 35: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Vattenfall Oxyfuel Powerplant Schwarze PumpeASU with LCO2 Tank

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 35

Page 36: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Vattenfall Oxyfuel Powerplant Schwarze PumpeCO2 Plant with LCO2 Tanks

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 36

Page 37: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation

Linde Engagement

„Coal or petcoke gasification, Oxygen for CO2-free power

generation, Hydrogen for refinery applications, LNG, and Gas To

Liquids, are all energy related development trends where Linde is

engaged and offers appropriate technologies and know-how “engaged and offers appropriate technologies and know-how.

Linde - the Pioneers of Air Separation – we are able to respond to

the challenge of producing cleaner fuel & energy for the growing

ld id d dworldwide demand.

(Dr. Aldo Belloni , CEO-Linde)

Bey/L/092009/Cottbus.pptLinde AG Engineering Division 37

Page 38: Enhanced Cryogenic Air SeparationEnhanced Cryogenic Air Separation