Flyer Inline
Transcript of Flyer Inline
-
8/10/2019 Flyer Inline
1/2
Absender/Sende
Name:
Firma/Company:
Abt./Position:
Adresse/Address
Tel./Phone:
E-Mail:
FAX-AN
IN-LINE FLOW
CONTROLS
FCI compact
IDEAL FOR
MONITORING
MINIMUM FLOWS
Bitte senden Sie m
Sensortechnik Induktive Sens Induktive Sens
Schwenkantrie uprox induktiv Kapazitive Sen Magnetfeldsen Opto-Sensore Gerte fr den Ultraschall-Se levelprox-Flls Strmungswc Druckwchter Temperaturw Identifikations Linearweg-Sen Drehweg-Sens Steckverbinde CD-ROM Sens
Interfacetechnik Interfacetechn
fr HutschienePlatten- oder B
Interfacetechnfr Baugruppe
Miniaturrelais, Zeitwrfel, Soc
Zeit- und ber Ex-Schutz Gr
die Praxis (be CD-ROM Interf
Feldbustechnik busstop-Feld Bussystemsen Bussystemsen Bussystemsen Bussystem AS Bussystem Dev Ethernet Netzw BL20 modul
I/O-System in BL67 modula
I/O-System in Bussystem FO
fieldbus Bussystem PRO Bussystem PR Bussystempic Remote I/O ex
Run-dry protection of pumpsIf the monitoring task involves
detection of whether the pump is
actually delivering the medium,
monitoring of the pumps feed
pressure is not sufficient. The
FCIcompactmonitors the actual
flow rate and indicates a change in
the flow speed. Pump systems are
thus securely run-dry protected.
Repair or replacement costs and
system down-times are eliminated.
FCI
FCI
FCI
M
FCIFCIFCI
Dosage rate monitoring
Many liquid proportioning
applications are timing
dependent.
The FCIcompact
monitors the contstant flow
during proportioning pro-
cedures and thus ensures
identical flows. With its
excellent response time,
the sensor is perfectly
suited to applications with short
proportioning intervals.
Monitoring of cooling circuits
During lubrication and cooling of
tools and installation components
the constant flow of cooling and
lubricating agents has to be moni-
tored to avoid system damages.
The FCIcompactimmediately
registers missing flows and signals
the need to shut-down machines
and systems.
Flow monitoring in filling
systems
To meet the demanding require-
ments of quality assurance in filling
lines, it must be assured that the
dosage rate is always identical
during the filling procedure. This is
another factor that is reliably moni-
tored by theFCIcompact.
If an FCI with analogue output is
used, even minor deviations of the
filling volume can be detected.
APPLICATIONS
-
8/10/2019 Flyer Inline
2/2
IN-LINE FLOW CONTROLS
FCI compact RELIABLE DETECTION OF
MINIMUM FLOWS
OVERVIEW: PRODUCTS AND APPLICATIONS
When monitoring flows in process
installations, it is generally of great
importance to detect variations of
the flow rate with as little delay as
possible.
The new TURCK series of flow
controls, called FCI compact, is
suited for detection of minimum
flow rates, regardless of various
application variables such as
system pressure, temperature,
viscosity and conductivity of theliquid.
TURCK offers a large variety of
devices with different process con-
nections, materials and operating
ranges for optimum adjustment to
specific application needs.
Ideal for low flow rates of 1 to
6000 ml/min
Optimally suited to applications
involving pulsing or periodic
flow rates due to a response time
of less than 1 second
Proven in-line technology with
integrated measuring pipes,
without any enclosed compo
nents to ensure minimum
pressure losses
Simple adjustment of the switch
point and monitoring range via
potentiometer
Optimally adaptable due to
various connection techniques
and materials
Customer-specific designs
Simple device configuration
Simple adjustment of the switch
point and monitoring range via
potentiometer during operation
Flow status display via a multi-
colour LED chain
Flexible application
For all non-explosive liquids
Various internal diameters for
optimum adjustment to the
flow volume
Special materials for aggressive
media on request
Threaded, flange or hygienic
connections for the food and
pharmaceutical industry.
Factory automation
TURCK offers versions for two
different flow rates and a choice of
transistor, relay or analogue output.
These devices are typically
designed for applications in which
water or liquid coolants are used
within a cooling circuit and where
machines and tools are lubricated
with oil or grease.
Food & pharmaceutical industry
In this context, not only the reliable
sensor function but also convenient
cleaning options are prime consi-
derations. The measuring pipe is
free of any in-built fixtures and usu-
ally features an extremely smooth
surface, so that it gives little cause
to contamination or caking: the
process connection is a DN10 Tri-
Clamp flange connector. Due to its
high temperature resistance, the
sensos does not have to be remo-
ved for cleaning (CIP.
Chem
If the
media
the se
Versio
cell in
cess c
meet
These
extrem
less th
Variable output
functions
Binary output for setpoint moni-
toring, relay or transistor versions
4...20 mA analogue output for
continuous flow volume
monitoring
Pulse output for detection of
periodic flow pulses
Type
FCI-D
FCI-D
FCI-D
Operamediu
Type
FCI-T
FCI-T
FCI-T
Operamediu
Type Mechanical connection Output Operating range [ml/min]
FCI-D04A4P-AP8X-H1141 G1/4 external thread pnp, NO 10...1000
FCI-D04A4P-ARX-H1140 G1/4 external thread relay, NO 10...1000
FCI-D04A4P-LIX-H1141 G1/4 external thread 4...20 mA 10...1000
FCI-D10A4P-AP8X-H1141 G1/4 external thread pnp, NO 100...6000
FCI-D10A4P-ARX-H1140 G1/4 external thread relay, NO 100...6000
FCI-D10A4P-LIX-H1141 G1/4 external thread 4...20 mA 100...6000Operating voltage 21...26 VDC, ambient temperature range 0...60 C,medium temperature -20...80 C (4...20 mA: 0...60 C)
Type Mechanical connection Output Operating range [ml/min]
FCI-34D10A4P-AP8X-H1141 DN10-Tri-Clamp pnp, NO 100...6000
FCI-34D10A4P-ARX-H1140 DN10-Tri-Clamp relay, MP 100...6000
FCI-34D10A4P-LIX-H1141 DN10-Tri-Clamp 4...20 mA 100...6000
Operating voltage 21...26 VDC, ambient temperature range 0...60 C,medium temperature -20...80 C, short-term rating -20...100 C (4...20 mA: 0...60 C, short-term rating 0...100 C)