Flyer Inline

download Flyer Inline

of 2

Transcript of Flyer Inline

  • 8/10/2019 Flyer Inline

    1/2

    Absender/Sende

    Name:

    Firma/Company:

    Abt./Position:

    Adresse/Address

    Tel./Phone:

    E-Mail:

    FAX-AN

    IN-LINE FLOW

    CONTROLS

    FCI compact

    IDEAL FOR

    MONITORING

    MINIMUM FLOWS

    Bitte senden Sie m

    Sensortechnik Induktive Sens Induktive Sens

    Schwenkantrie uprox induktiv Kapazitive Sen Magnetfeldsen Opto-Sensore Gerte fr den Ultraschall-Se levelprox-Flls Strmungswc Druckwchter Temperaturw Identifikations Linearweg-Sen Drehweg-Sens Steckverbinde CD-ROM Sens

    Interfacetechnik Interfacetechn

    fr HutschienePlatten- oder B

    Interfacetechnfr Baugruppe

    Miniaturrelais, Zeitwrfel, Soc

    Zeit- und ber Ex-Schutz Gr

    die Praxis (be CD-ROM Interf

    Feldbustechnik busstop-Feld Bussystemsen Bussystemsen Bussystemsen Bussystem AS Bussystem Dev Ethernet Netzw BL20 modul

    I/O-System in BL67 modula

    I/O-System in Bussystem FO

    fieldbus Bussystem PRO Bussystem PR Bussystempic Remote I/O ex

    Run-dry protection of pumpsIf the monitoring task involves

    detection of whether the pump is

    actually delivering the medium,

    monitoring of the pumps feed

    pressure is not sufficient. The

    FCIcompactmonitors the actual

    flow rate and indicates a change in

    the flow speed. Pump systems are

    thus securely run-dry protected.

    Repair or replacement costs and

    system down-times are eliminated.

    FCI

    FCI

    FCI

    M

    FCIFCIFCI

    Dosage rate monitoring

    Many liquid proportioning

    applications are timing

    dependent.

    The FCIcompact

    monitors the contstant flow

    during proportioning pro-

    cedures and thus ensures

    identical flows. With its

    excellent response time,

    the sensor is perfectly

    suited to applications with short

    proportioning intervals.

    Monitoring of cooling circuits

    During lubrication and cooling of

    tools and installation components

    the constant flow of cooling and

    lubricating agents has to be moni-

    tored to avoid system damages.

    The FCIcompactimmediately

    registers missing flows and signals

    the need to shut-down machines

    and systems.

    Flow monitoring in filling

    systems

    To meet the demanding require-

    ments of quality assurance in filling

    lines, it must be assured that the

    dosage rate is always identical

    during the filling procedure. This is

    another factor that is reliably moni-

    tored by theFCIcompact.

    If an FCI with analogue output is

    used, even minor deviations of the

    filling volume can be detected.

    APPLICATIONS

  • 8/10/2019 Flyer Inline

    2/2

    IN-LINE FLOW CONTROLS

    FCI compact RELIABLE DETECTION OF

    MINIMUM FLOWS

    OVERVIEW: PRODUCTS AND APPLICATIONS

    When monitoring flows in process

    installations, it is generally of great

    importance to detect variations of

    the flow rate with as little delay as

    possible.

    The new TURCK series of flow

    controls, called FCI compact, is

    suited for detection of minimum

    flow rates, regardless of various

    application variables such as

    system pressure, temperature,

    viscosity and conductivity of theliquid.

    TURCK offers a large variety of

    devices with different process con-

    nections, materials and operating

    ranges for optimum adjustment to

    specific application needs.

    Ideal for low flow rates of 1 to

    6000 ml/min

    Optimally suited to applications

    involving pulsing or periodic

    flow rates due to a response time

    of less than 1 second

    Proven in-line technology with

    integrated measuring pipes,

    without any enclosed compo

    nents to ensure minimum

    pressure losses

    Simple adjustment of the switch

    point and monitoring range via

    potentiometer

    Optimally adaptable due to

    various connection techniques

    and materials

    Customer-specific designs

    Simple device configuration

    Simple adjustment of the switch

    point and monitoring range via

    potentiometer during operation

    Flow status display via a multi-

    colour LED chain

    Flexible application

    For all non-explosive liquids

    Various internal diameters for

    optimum adjustment to the

    flow volume

    Special materials for aggressive

    media on request

    Threaded, flange or hygienic

    connections for the food and

    pharmaceutical industry.

    Factory automation

    TURCK offers versions for two

    different flow rates and a choice of

    transistor, relay or analogue output.

    These devices are typically

    designed for applications in which

    water or liquid coolants are used

    within a cooling circuit and where

    machines and tools are lubricated

    with oil or grease.

    Food & pharmaceutical industry

    In this context, not only the reliable

    sensor function but also convenient

    cleaning options are prime consi-

    derations. The measuring pipe is

    free of any in-built fixtures and usu-

    ally features an extremely smooth

    surface, so that it gives little cause

    to contamination or caking: the

    process connection is a DN10 Tri-

    Clamp flange connector. Due to its

    high temperature resistance, the

    sensos does not have to be remo-

    ved for cleaning (CIP.

    Chem

    If the

    media

    the se

    Versio

    cell in

    cess c

    meet

    These

    extrem

    less th

    Variable output

    functions

    Binary output for setpoint moni-

    toring, relay or transistor versions

    4...20 mA analogue output for

    continuous flow volume

    monitoring

    Pulse output for detection of

    periodic flow pulses

    Type

    FCI-D

    FCI-D

    FCI-D

    Operamediu

    Type

    FCI-T

    FCI-T

    FCI-T

    Operamediu

    Type Mechanical connection Output Operating range [ml/min]

    FCI-D04A4P-AP8X-H1141 G1/4 external thread pnp, NO 10...1000

    FCI-D04A4P-ARX-H1140 G1/4 external thread relay, NO 10...1000

    FCI-D04A4P-LIX-H1141 G1/4 external thread 4...20 mA 10...1000

    FCI-D10A4P-AP8X-H1141 G1/4 external thread pnp, NO 100...6000

    FCI-D10A4P-ARX-H1140 G1/4 external thread relay, NO 100...6000

    FCI-D10A4P-LIX-H1141 G1/4 external thread 4...20 mA 100...6000Operating voltage 21...26 VDC, ambient temperature range 0...60 C,medium temperature -20...80 C (4...20 mA: 0...60 C)

    Type Mechanical connection Output Operating range [ml/min]

    FCI-34D10A4P-AP8X-H1141 DN10-Tri-Clamp pnp, NO 100...6000

    FCI-34D10A4P-ARX-H1140 DN10-Tri-Clamp relay, MP 100...6000

    FCI-34D10A4P-LIX-H1141 DN10-Tri-Clamp 4...20 mA 100...6000

    Operating voltage 21...26 VDC, ambient temperature range 0...60 C,medium temperature -20...80 C, short-term rating -20...100 C (4...20 mA: 0...60 C, short-term rating 0...100 C)