Group 1 Mappe

28
Präsentation BIM Gruppe 1 Architektur_Lena Gotzl Tragwerksplanung_Martin Neier Building Science_Bebe Ivan

description

office building plan

Transcript of Group 1 Mappe

Page 1: Group 1 Mappe

Präsentation BIM

Gruppe 1

Architektur_Lena Gotzl

Tragwerksplanung_Martin Neier

Building Science_Bebe Ivan

Page 2: Group 1 Mappe
Page 3: Group 1 Mappe
Page 4: Group 1 Mappe
Page 5: Group 1 Mappe
Page 6: Group 1 Mappe
Page 7: Group 1 Mappe
Page 8: Group 1 Mappe
Page 9: Group 1 Mappe

Tragstruktur

Page 10: Group 1 Mappe

Aussteifung

Page 11: Group 1 Mappe

Angesetzte Lasten

• Ständige Lasten

• Eigengewicht

• Ausbaulasten

• Fassade

• Variable Lasten

• Nutzlasten

• Intandsetzung

• Schnee

• Wind

Page 12: Group 1 Mappe

Max. Verformungen

Page 13: Group 1 Mappe

Maßgebende Stütze

Stütze: 60 / 25

As,erf = 42,4 cm²

( 8 ø 26 )

Page 14: Group 1 Mappe

STB – Massen lt. FEM Programm

Page 15: Group 1 Mappe

Energy concept

Page 16: Group 1 Mappe

Table of U-values

Area

[m²]

U-value

[W.m-2.K-1]

External walls 7376 0.102

Windows 1196 0.73

Roof 1252 0.188

Ground 332 0.343

Settings

Project

location Wien-Penzing

above sea level [m] 171

cadastral community 14

indoor temperature [°C] 20

heating degree days [Kd] 205

area [m²] 6700

floors 6

Building elementsconstruction Concrete structure

U-Values - range [W.m-2.K-1] 0.102- 0.73

Installations

heating Central

warm water Central

ventilation Mechanical/ natural

lighting Artificial/ daylight

cooling AC/ night

Building

type office

area [m²] 6700

volume [m³] 33437

envelope area [m²] 10156

opaque [m²] 8628

transparent [m²] 1196

against outside [m²] 9824

Heating demand

air change rate [1/h] 6

indoor temperature [°C] 20

outdoor temperature[°C]

-12.6

HWB reference [kWh.m-2.a-1] 12.99

HWB location [kWh.m-2.a-1] 13.19

U-Value average [kWh.m-2.a-1] 0.211

Energy certificate

Page 17: Group 1 Mappe

Class A building

Page 18: Group 1 Mappe

Energy simulation

• all round board shades 0.2 / 1.2 m

• improvement of heating and cooling gains

• natural and artificial ventilations in crucial zones

Page 19: Group 1 Mappe

Heating and Cooling loads

Page 20: Group 1 Mappe

Ventilation concept

• main ventilation fan on the roof

• pipes will be inserted through special chambers

• air that goes in = air that goes out

• Heating, ventilation and air conditioning all together

• fresh air goes in via pipes situated near the windows

Page 21: Group 1 Mappe

Ventilation floor plans

First floor

Ground floor

Page 22: Group 1 Mappe

Ventilation

Ground floor

Upper floor

• each floor will have 4 main fresh air supply/ absorbent pipes

• 0.75 x 2 m is the size of each main pipe

• medium air change rate: 5.81

Page 23: Group 1 Mappe
Page 24: Group 1 Mappe

Illumination

Page 25: Group 1 Mappe

Illumination

First floor

Ground floor

Page 26: Group 1 Mappe

Illumination – ground floor

Isolines

Grayscale Value chart

• led based luminaries

• possibility of manually dimming of

light

• luminance values according to the

norms, even without natural light

Page 27: Group 1 Mappe

Fire safety plans

Ground floor

First floor

Basement

• max area per fire section in normal floor < 1600 m²

• max area per fire section in basement < 800 m²

• exit routes < 40m

Considered aspects: • Assembly points

• Exit routes

• Fire sections

• Staircases

Page 28: Group 1 Mappe

Thank you