    LPHAWIND MF

    Installation & operation manual

    ALPHATRON MARINE B.V.Schaardijk 233063 NH ROTTERDAM

    The NetherlandsTel: +31 (0)10 453 4000Fax: +31 (0)10 452 9214

    P.O. Box 210033001 AA ROTTERDAM

    Web: www.alphatronmarine.comMail: [email protected]

    Information in this manual can be updated without furthernotice. No rights can be derived from this manual.

    Document : Manual ALPHAWIND MFRevision : 1.4 ALPHATRON MARINE B.V.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    2/52

    Manual ALPHAWIND MF version 1.4 Page 2 of 52

    ALPHAWIND MF

    Table of contents:

    1 REVISION HISTORY .................................................................................................. 52 INTRODUCTION ....................................................................................................... 63 INSTALLATION ......................................................................................................... 7

    3.1 Supplied parts ................................................................................................... 73.2 Positioning the ALPHAWIND MF ........................................................................... 8

    3.2.1 ALPHAWIND MF flush mounted ..................................................................... 83.2.2 ALPHAWIND MF bulkhead .......................................................................... 10

    3.3 Connecting the ALPHAWIND MF ......................................................................... 113.3.1 Cable assembly ........................................................................................ 123.3.2 Earthing the ALPHAWIND MF ...................................................................... 133.3.3 Connecting the power supply ...................................................................... 133.3.4 Connecting the analogue wind sensor (anemometer) ..................................... 143.3.5 Connecting a digital (NMEA) wind sensor ..................................................... 153.3.6 Connection of the central dimming signal ..................................................... 16

    3.4 Accepted NMEA data sentences ......................................................................... 18

    4 ALPHAWIND MFMF OPERATION ............................................................................... 214.1 Push buttons ................................................................................................... 21

    4.1.1 Switching the ALPHAWIND MF on ................................................................ 214.1.2 Switching the ALPHAWIND MF off ................................................................ 21

    4.2 Work mode/statuses ........................................................................................ 224.2.1 Normal mode ........................................................................................... 224.2.2 Alarm mode ............................................................................................. 234.2.3 Dim mode (dimming the backlight) ............................................................. 244.2.4 Menu mode (using the menu) ..................................................................... 25

    5 SCHEMATIC COMPOSITION OF THE MENU STRUCTURE ............................................... 456 FIRMWARE REVISION ............................................................................................. 467 TROUBLESHOOTING ............................................................................................... 46

    8 TECHNISCHE SPECIFICATIONS ................................................................................ 469 TECHNICAL SUPPORT ............................................................................................. 4610 ALPHATRON Dealers Deep-sea (Authorized) ........................................................... 4711 ALPHATRON Dealers Inland Shipping (Authorized) .................................................. 4812 Appendix 1: Mounting frame ................................................................................ 4913 Appendix 2: Instrument dimensions ...................................................................... 5014 Appendix 3: Complete connection diagram ............................................................. 5115 NOTES: ............................................................................................................. 52

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    3/52

    Manual ALPHAWIND MF version 1.4 Page 3 of 52

    ALPHAWIND MF

    Figures and images:

    Figure 1: The complete hardware of the ALPHAWIND MF ..................................................... 7Figure 2: Possible positions for flush mounting ................................................................... 8Figure 3: Flush mounting frame ........................................................................................ 9Figure 4: Bulkhead frame MF line .................................................................................... 10

    Figure 5: ALPHAWIND MF connectors .............................................................................. 11Figure 6: Cable assembly ............................................................................................... 12Figure 7: Correct cable assembly .................................................................................... 12Figure 8: Correct earthing of the instrument .................................................................... 13Figure 9: Power supply connection .................................................................................. 13Figure 10: Anemometer Figure 11: Anemometer internal schematic ........................... 14Figure 12: Connecting the analogue signal ....................................................................... 14Figure 13: Connecting the digital/NMEA signal .................................................................. 15Figure 14: Connecting the central dimming system ........................................................... 16Figure 15: Central dimming system (CAN bus) ................................................................. 17Figure 16: 1) left button, 2) right button, 3) on/off button, 4) dim/menu/enter button .... 21Figure 17: ALPHAWIND MF in normal mode ...................................................................... 22

    Figure 18: ALPHAWIND MF in alarm mode ....................................................................... 23Figure 19: Dimming mode ............................................................................................. 24Figure 20: Menu cursor in the LCD display ....................................................................... 25Figure 21: Main menu ................................................................................................... 26Figure 22: Backlight menu ............................................................................................. 27Figuur 23: Central dim menu .......................................................................................... 28Figuur 24: Background menu ......................................................................................... 28Figure 25: Language menu ............................................................................................ 29Figure 26: Unit settings menu ........................................................................................ 30Figure 27: Service menu ................................................................................................ 31Figure 28: Analogue LOG menu ...................................................................................... 32Figure 29: NMEA digital LOG menu.................................................................................. 33

    Figure 30: CAN settings menu ........................................................................................ 34Figure 31: CAN address menu ........................................................................................ 35Figure 32: Example Dim groups ...................................................................................... 36Figure 33: Dim group menu ........................................................................................... 37Figure 34: Dim limit menu ............................................................................................. 38Figure 35: Offset menu .................................................................................................. 39Figure 36: Offset direction wind sensor ............................................................................ 40Figure 37: Offset pointer menu ....................................................................................... 41Figure 38: Reset all offsets menu .................................................................................... 42Figure 39: Sensor type menu ......................................................................................... 43Figure 40: Factory settings menu .................................................................................... 44

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    4/52

    Manual ALPHAWIND MF version 1.4 Page 4 of 52

    ALPHAWIND MF

    CAUTION!

    DO NOT modify this equipment in any way without obtaining a writtenpermission from ALPHATRON MARINE, otherwise you will void the warranty.

    CAUTION!

    This product is only to be installed by a certified installation company, eitherapproved by ALPHATRON MARINE or by one of its distributors, otherwise you

    will void the warranty. This product must be installed according to theprescribed installation methods in this manual, otherwise you will void thewarranty.

    CAUTION!

    Alphaline MF instruments contain no operator serviceable parts. Service andrepair of both units shall only be done by trained and certified personal.

    Nothing from this manual may be multiplied and/or published by means of press, photocopy, microfilm or any otherway, without written consent beforehand by Alphatron Marine B.V.

    Even though this manual has been composed with the utmost precision, Alphatron will not accept any responsibility for

    the consequences of possible inaccuracies.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    5/52

    Manual ALPHAWIND MF version 1.4 Page 5 of 52

    ALPHAWIND MF

    1 REVISION HISTORY

    Revision number Description Date

    V1.0 Document drawn up 07/03/08V1.1 Menu for adjusting offset indicator transferred 23/06/08to the service menu instead of settings menu.

    V1.2 Changed menu structure (offset menus) 23/12/08Added LOG menu.NMEA outputs $--MWV, when analogue input is selected.

    V1.3 0 Added central dimming and CAN Bus menus 16/11/090 changed standard of NMEA sentences intoIEC61162-1 standard instead of NMEA 0183 standard.

    V1.4 Paragraaf 4.2.4.3 en 4.2.4.4 added, 4.2.4.2 09/07/10changed; switching central dim on/off is moved toa new menu, a submenu to switch the backlight onor off is added.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    6/52

    Manual ALPHAWIND MF version 1.4 Page 6 of 52

    ALPHAWIND MF

    2 INTRODUCTIONThe ALPHAWIND MF is designed for analogue and digital displaying of the relative wind directionand wind speed. The analogue pointer/indicator provides a clear indication of the wind direction,and at the same time the wind speed can be digitally read from the LCD screen. An analogue ora digital (NMEA) wind sensor can be connected to the ALPHAWIND MF.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    7/52

    Manual ALPHAWIND MF version 1.4 Page 7 of 52

    ALPHAWIND MF

    3 INSTALLATION3.1 Supplied partsThe ALPHAWIND MF hardware consists of the following parts:

    Mounting frame ALPHAWIND MF indicator 4x Signal connector 1x Power supply connector

    Figure 1: The complete hardware of the ALPHAWIND MF

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    8/52

    Manual ALPHAWIND MF version 1.4 Page 8 of 52

    ALPHAWIND MF

    3.2 Positioning the ALPHAWIND MFThe ALPHAWIND MF can be mounted in a number of ways. The ALPHAWIND MF can bedelivered as a flush mounted or a bulkhead mounted instrument.

    3.2.1 ALPHAWIND MF flush mountedThe ALPHAWIND MF can be placed horizontally, vertically as well as under an angle. Figure 2shows the positions for flush mounting.

    Figure 2: Possible positions for flush mounting

    In order to mount the ALPHAWIND MF, the flush mounting frame needs to be built-in first. Ahole with the measurements of the flush mounting frame needs to be made in the bridge oroverhead console. The measurements of the flush mounting frame can be found in the appendixof this manual.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    9/52

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    10/52

    Manual ALPHAWIND MF version 1.4 Page 10 of 52

    ALPHAWIND MF

    3.2.2 ALPHAWIND MF bulkheadThe bulkhead ALPHAWIND MF requires an extra DIN 144 bulkhead frame. This bulkhead frameis not part of the standard delivery. Also see figure 4.

    Figure 4: Bulkhead frame MF line

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    11/52

    Manual ALPHAWIND MF version 1.4 Page 11 of 52

    ALPHAWIND MF

    3.3 Connecting the ALPHAWIND MFThe ALPHAWIND MF has five different connectors on the rear side of the instrument. These arefour signal connectors and one power supply connector. These various connectors and theirfunction are described below. Also see figure 5.

    Connector 1 = Power supply connection (Galvanically separated) Connector 2 = Digital/NMEA input (Galvanically separated) Connector 3 = CAN data / central dimming (Galvanically separated) Connector 4 = Not connected / NC Connector 5 = Analogue input (Galvanically separated)

    Figure 5: ALPHAWIND MF connectors

    Connector 1Power supply

    Connector 5Analogue

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    12/52

    Manual ALPHAWIND MF version 1.4 Page 12 of 52

    ALPHAWIND MF

    3.3.1 Cable assemblyIt is important that all cables are assembled correctly, otherwise the instrument will not workproperly. Cables need to be prepared according to figure 6.

    Figure 6: Cable assembly

    Note:The earth cover/shield needs to be cut only halfway in order to slide it back over the cablejacket. Then, a little more than half of the earth cover/shield that has been slid back will beattached to cable jacket with tape. The remaining uncovered piece of the earth cover/shield thathas been slid back needs to be attached under the metal clasp on the back of the instrument.See figure 7.

    Figure 7: Correct cable assembly

    This will ensure the optimum protection effect of the earth cover/cable shield.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    13/52

    Manual ALPHAWIND MF version 1.4 Page 13 of 52

    ALPHAWIND MF

    3.3.2 Earthing the ALPHAWIND MFIn order to function properly, the instrument needs to be earthed. An earthing point can befound on the right side next to the signal connectors on the back of the instrument. Thisearthing point must be connected via a low impedance connection to the ship's mass. Thismeans using a thick and as short as possible wire or earth shield. See figure 8.

    Figure 8: Correct earthing of the instrument

    3.3.3 Connecting the power supplyThe ALPHAWIND MF needs to be connected to a 10VDC - 40VDC power supply that can supplyat least 1.0 ampere. The power supply connection is Connector 1 in figure 5. The polarity of thepower supply connection is presented on the power supply circuit board as well as on theconnection sticker on the backside of the instrument. If the power supply connectors areconnected the wrong way around, the fuse will burn-out/blow. However, the instrument will notbe damaged. The maximum diameter of the connectable wire is 2.5mm. The completeconnection diagram of the ALPHAWIND MF can be found in the appendix of this manual.

    Figure 9: Power supply connection

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    14/52

    Manual ALPHAWIND MF version 1.4 Page 14 of 52

    ALPHAWIND MF

    3.3.4 Connecting the analogue wind sensor (anemometer)The ALPHAWIND MF can be connected to an anemometer. The standard type anemometer thatis used is the Davis (type 7911) anemometer.

    Figure 10: Anemometer Figure 11: Anemometer internal schematic

    The anemometer includes a potentiometer and a reed relay. The potentiometer indicates thewind direction, and needs to be connected to pins 17, 20 and 21 of the analogue input. Thereed relay has already been connected to one side of the internal power supply (POT+). Thereed relay output needs to be connected to pin 22 of the analogue input. Also take a look atfigure 11 and the connection diagram in the appendix of this manual.

    Figure 12: Connecting the analogue signal

    Reed-relay

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    15/52

    Manual ALPHAWIND MF version 1.4 Page 15 of 52

    ALPHAWIND MF

    3.3.5 Connecting a digital (NMEA) wind sensorThe ALPHAWIND MF can be connected to a digital wind sensor. This can be of any type, as longas the sensor sends its data via an RS422/485 connection. This serial connection needs to beconnected to connector 2, also see figure 5. These are the connections with pin numbers 31 and32. This digital sensor cannot be powered by the ALPHAWIND MF and will therefore have to be

    connected to an external power supply. The information sent by the digital sensor needs tocomply with the specifications as mentioned in chapter 3.4. The complete connection diagram ofthe ALPHAWIND MF can be found in the appendix of this manual.

    Figure 13: Connecting the digital/NMEA signal

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    16/52

    Manual ALPHAWIND MF version 1.4 Page 16 of 52

    ALPHAWIND MF

    3.3.6 Connection of the central dimming signalIt is possible to connect the ALPHAWIND MF to a central dimming system. This central dimmingsystem works by use of a CAN bus system, and can only function between the variousinstruments of the Alphaline MF and the Alphaline MFD. The instrument needs to be connectedto the CAN bus with connection 1 and 2 of signal connector 3. The complete connection diagram

    of the ALPHAWIND MF can be found in the appendix of this manual. See also figure 14 below.

    Figure 14: Connecting the central dimming system

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    17/52

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    18/52

    Manual ALPHAWIND MF version 1.4 Page 18 of 52

    ALPHAWIND MF

    3.4 Accepted NMEA data sentencesThe ALPHAWIND MF accepts asynchronous serial data at 4800 baud via its RS485/RS422inputs. This data needs to consist of data frames of 8 data bits, 1 stop bit and no parity bits.

    Baud rate = 4800Data bits = 8 (bit D7 is always zero)Parity = noneStop bits = 1

    All received data will be interpreted as ASCII characters which together need to form NMEAsentences compliant to IEC61162-1. Accepted sentences of the ALPHAWIND MF:

    Start D0 D1 D2 D3 D4 D5 D6 D7=0 Stop

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    19/52

    Manual ALPHAWIND MF version 1.4 Page 19 of 52

    ALPHAWIND MF

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    20/52

    Manual ALPHAWIND MF version 1.4 Page 20 of 52

    ALPHAWIND MF

    These data sentences need to be received with an interval of at least once and a maximum of10 times per second.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    21/52

    Manual ALPHAWIND MF version 1.4 Page 21 of 52

    ALPHAWIND MF

    4 ALPHAWIND MFMF OPERATIONThis section explains how the ALPHAWIND MF is operated.

    4.1 Push buttonsIn order to operate the ALPHAWIND MF, four push buttons have been placed on the front of theinstrument. The only button with a fixed function is the ON/OFF button. This button can only beused to switch the instrument on or off. This button works under all circumstances.

    The other three buttons have various functions depending on the mode the instrument is in atthat moment.

    Figure 16: 1) left button, 2) right button, 3) on/off button, 4) dim/menu/enter button

    During normal operation the only button functioning is the DIM/MENU/ENTER button. Thisbutton can be used to go to dimming or menu mode. If the instrument is in alarm (alarmmode), this button can be used to accept the alarm. The left and right buttons only functionduring dimming and menu mode.

    4.1.1 Switching the ALPHAWIND MF onIn order to switch on the ALPHAWIND MF the on/off button needs to be pressed shortly. Theinstrument will switch on immediately. The LCD screen will display the instrument type andsoftware version. The analogue pointer will calibrate itself.

    4.1.2 Switching the ALPHAWIND MF offIn order to switch off the ALPHAWIND MF the on/off button needs to be pressed forapproximately 5 seconds. The instrument will switch off after 5 seconds. The LCD screen will

    turn black and the analogue pointer or scale will stop immediately at the value that it presentedlast.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    22/52

    Manual ALPHAWIND MF version 1.4 Page 22 of 52

    ALPHAWIND MF

    4.2 Work mode/statusesThe ALPHAWIND MF can be in one of the four possible modes/statuses. These are:

    Normal mode Alarm mode

    Dim mode Menu mode

    4.2.1 Normal modeIf there are no alarms and if the instrument is not in dim or menu mode, the instrument is innormal mode. While in this mode, the instrument's pointer/indicator will indicate the relativewind direction related to the ship. The wind speed can be read from the LCD screen. Themeasured peak wind speeds (max wind) can also be read from the display. Also see figure 17.

    Figure 17: ALPHAWIND MF in normal mode

    The ALPHAWIND MF can also provide the outside temperature and the barometrical atmosphericpressure. This data does need to be sent out by the wind sensor. The data needs to be receivedin the form of correct NMEA sentences. A list of the accepted NMEA data sentences can befound in chapter 3.4.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    23/52

    Manual ALPHAWIND MF version 1.4 Page 23 of 52

    ALPHAWIND MF

    4.2.2 Alarm modeWhen the ALPHAWIND MF is connected to an analogue wind sensor, no alarms can becomeactive. The two types of alarms can only become active when the ALPHAWIND MF is connectedto a digital (NMEA) wind sensor. These two types of alarms are:

    1. No NMEA data alarm (NMEA Time-out) 2. Invalid NMEA data alarm

    The definitions of these alarms will be explained in the next chapter. If either one of the alarmsbecomes active, the instrument's backlight will turn red and start flashing and a buzzer/audiotone will be heard. The display will display the text of the alarm. The instrument is now in alarmmode.

    Figure 18: ALPHAWIND MF in alarm mode

    If the cause of the alarm is now corrected, the instrument will automatically go back to normalmode. The backlight will go back from blinking red to the originally selected colour, and thebuzzer/audio tone will switch off. The alarm text will disappear from the screen.

    If the cause of the alarm is not corrected, the alarm needs to be accepted first. This can bedone by shortly pressing the dim/menu button. The backlight will go back from blinking red tothe originally selected colour, and the buzzer/audio tone will switch off. However, as long as thealarm is not corrected, the alarm text will remain in the display. If the cause of the alarm iscorrected, the instrument will go back to normal mode. The alarm text will disappear from thescreen.

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    24/52

    Manual ALPHAWIND MF version 1.4 Page 24 of 52

    ALPHAWIND MF

    4.2.2.1NMEA time-out alarmThe first type of alarm is the NMEA time-out alarm. See figure 18. This alarm will automaticallybe activated if the instrument does not receive NMEA data for a period of 5 seconds or longer.This alarm can only be deactivated by sending the correct NMEA data to the instrument.

    4.2.2.2Invalid data alarmThe second alarm is the NMEA invalid data alarm. This alarm is activated if the instrumentreceives more than 5 NMEA sentences with invalid data in the data fields. This alarm isdeactivated if one sentence is received fully correctly.

    4.2.3 Dim mode (dimming the backlight)The brightness of the backlight of the instrument can be adjusted in 15 steps from 1 to 100%.In order to adjust the brightness of the backlight, the instrument needs to be set to dimming

    mode. The dimming mode can only be activated from the normal mode. This can be done byshortly pressing the 'dim/menu' button. The display will now show the brightness level of thebacklight in text as well as graphically. See figure 19.

    Figure 19: Dimming mode

    By shortly pressing the 'left' button, the brightness of the backlight will decrease by one step.By shortly pressing the 'right' button, the brightness of the backlight will increase by one step.

    Note: Continuously pressing the 'left' or 'right' button does not affect the brightness of the backlight. Only pressing and release will!

    If none of the buttons are pressed for 3 or 4 seconds, the instrument will automatically returnto normal mode.

    Backlight 75%

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    25/52

    Manual ALPHAWIND MF version 1.4 Page 25 of 52

    ALPHAWIND MF

    4.2.4 Menu mode (using the menu)The instrument's settings can be changed via the menu. This menu can be used to adjust theinstrument's backlight colour or calibrate the instrument. The menu can be opened by pressingthe 'dim/menu' button for approximately 6 seconds. The main menu will now appear in the LCDscreen.

    If the main menu, backlight or language menu is opened and none of the buttons are pressedfor 5 seconds or longer, the menu will automatically close. The instrument will now return tonormal mode. This function has been disabled in all other menus.

    Selection of and navigating through the menus is done with a round cursor on the left side ofthe display. See figure 20.

    Figure 20: Menu cursor in the LCD display

    This cursor can be used to select and open menus and submenus or select and activate menuitems. In order to select a submenu or menu item, the cursor can be moved up and down byusing The left and right buttons.

    In order to open a submenu or activate a menu item, the cursor needs to be placed in front ofthe relevant menu or item. It is now possible to open this menu or activate this item by

    pressing the 'dim/menu' button.

    The menu mode can be closed by selecting and activating the 'Exit' option in the main menu.The menu mode will now be closed down and the instrument will automatically return to normalmode.

    Main menu

    Backlight

    Language

    Settings

    Service menu

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    26/52

    Manual ALPHAWIND MF version 1.4 Page 26 of 52

    ALPHAWIND MF

    4.2.4.1Main menuThe main menu is the start menu. This menu directs to various submenus and the 'Exit' optionwill close down the menu. The instrument will now return to normal mode.

    Figure 21: Main menu

    This main menu opens the following submenus:

    Backlight menu Language menu Settings menu Service menu

    Main menu

    Backlight

    Language

    Settings

    Service menu

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    27/52

    Manual ALPHAWIND MF version 1.4 Page 27 of 52

    ALPHAWIND MF

    4.2.4.2Backlight menuThis menu is used to choose the instruments backlight colour and switch the central dimmingon or off. There are three possible backlight colours.

    Red

    Green White

    The left and right buttons can be used to select the desired colour. The selected colour can beactivated by pressing the 'dim/menu' button. The backlight colour changes immediately aftershortly pressing the 'dim/menu' button.

    From this menu, a submenu can be opened to switch the central dim on or off. To do so, theCentral dim menu item must be selected and activated.From this menu, another submenu can be opened to switch the backlight on or off, the

    Background menu. If the option in this menu is set to backlight off, the backlight will switchoff after 10 seconds when no buttons are pressed or no central dimming/central configuring is

    in progress. This menu can be opened by selecting it with the left- and right-keys and shortlypressing the dim/menu button.

    Select and activate the 'Exit' option to close this menu. The instrument will now return to themain menu.

    Figure 22: Backlight menu

    4.2.4.3Central dim menuThis menu is used to switch the central dimming on or off. The rectangle indicates the currentactive central dimming setting. The left and right buttons can be used to select the desiredsetting. The selected colour can be activated by pressing the 'dim/menu' button. The backlightcolour changes immediately after shortly pressing the 'dim/menu' button.

    Backlight menu

    Red

    Green

    White

    Central dim menu

    Background menu

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    28/52

    Manual ALPHAWIND MF version 1.4 Page 28 of 52

    ALPHAWIND MF

    Figure 23: Central dim menu

    In order to close the central dim menu, the Exit option must be selected and activated. Thedevice will return to the Backlight menu.

    4.2.4.4Background menuThis menu is used to switch the background on or off. The rectangle indicates the current activecentral dimming setting. The left and right buttons can be used to select the desired setting.When Background OFF is set, the background will automatically switch off when none of thebuttons is pressed for about ten seconds, the device is not dimmed or controlled remotely andno alarm is active. When the backlight is switched off, it will switch on when a button ispressed, the device is dimmed or controlled remotely or when an alarm becomes active.When Background ON is set, the backlight will always be on.The desired selection can be selected with the left- and right buttons. A short press on the

    dim/menu button will save and activate the selection.

    Figure 24: Background menu

    Central dim menu

    Central dim ON

    Central dim OFF

    Exit

    Background menu

    Background ON

    Background OFF

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    29/52

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    30/52

    Manual ALPHAWIND MF version 1.4 Page 30 of 52

    ALPHAWIND MF

    4.2.4.6Settings menuThis settings (or user's) menu can be used to adjust the unit of the wind speed. This menu canalso be used to reset the peak wind speed or to open the submenu in order to adjust the type ofwind sensor used.

    Figure 26: Unit settings menu

    The left and right buttons can be used to select the menu items. The unit currently in use isindicated with a selection rectangle. Menu items one to three are the possible units for windspeed (Bft, knots, m/s). Select and activate the desired wind speed unit by pressing the

    dim/menu button. The selection rectangle will now jump to the selected wind unit. Select andactivate the 'Exit' option in order to return to the main menu.

    Reset the peak wind speed by selecting and activating the menu item Reset max wind. Afterresetting select and activate the Exit menu option. When returned to the normal mode, thedisplayed peak value will be equal to the current wind speed.

    Unit settings

    Bft

    Knots

    m/s

    Reset max wind

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    31/52

    Manual ALPHAWIND MF version 1.4 Page 31 of 52

    ALPHAWIND MF

    4.2.4.7 Service menuThe service menu opens the various settings menus or activates the NMEA monitor/scanner. Ifthe service menu is opened, a password is requested. This option has been added in order toprevent unauthorised people to enter the service menu. Select and activate the 'Enter' optionby pressing the 'dim/menu' button shortly twice. The service menu will now open.

    Figure 27: Service menu

    The left and right buttons can be used to select the desired submenus. They can be openedby pressing the dim/menu button.

    This service menu opens the following submenus:

    LOG menu CAN settings Offset menu Sensor type menu Factory settings menu

    Service menu

    LOG menu

    CAN setting

    Offset menuSensor type

    Factory settings

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    32/52

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    33/52

    Manual ALPHAWIND MF version 1.4 Page 33 of 52

    ALPHAWIND MF

    When using the digital NMEA input to read the wind direction and speed, the LOG menu willindicate the following:

    Figure 29: NMEA digital LOG menu

    After the NMEA sentences have been received, they are displayed at the top of the screen. TheTime-out value indicates how long ago a correct NMEA sentence has been received. TheError_Cntr indicates how many received NMEA data sentences are invalid. When there is a goodconnection, the Error_Cntr will not be set to 1 very often, and if, it will immediately go back to0. The menu also indicates an internal register variable. According to the given variable value,the instrument can determine whether for instance the push buttons are read by the processor.

    Note: The communication ports of this instrument are of the RS485/422 type. These

    communication standards have a + and a - potential which need to be connected withthe correct potential to the correct connector pins of the instrument. The instrumentwill not receive data if the polarity of the connected signal does not match the polarity

    of the instrument's ports.

    Last received

    NMEA sentence

    NMEA time-out timer

    Digital LOG

    Time-out=1

    Error_Cntr = 0

    F_update = 53378

    $WIMWV,357.0R,10.5,K,A*22\r\n

    Invalid / errorsentences counter

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    34/52

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    35/52

    Manual ALPHAWIND MF version 1.4 Page 35 of 52

    ALPHAWIND MF

    4.2.4.9CAN address menuIf the instrument is used in a central dimming or control system of multiple instruments, eachinstrument should have a unique CAN address. The instrument's CAN address can be set in theCAN address menu.

    Figure 31: CAN address menu

    It is important that each instrument on the same CAN network has a unique address. The CAN

    address can be increased or decreased via the options CAN address +1 and CAN address -1.Choose one of the options and then press the dim/menu button. The CAN address is displayedat the bottom of the display. Save the CAN address to the memory by selecting the Enteroption and shortly press the 'dim/menu' button. The instrument will now automatically return tothe CAN settings menu.

    Select and activate the 'Exit' option in order to return to the CAN settings menu. Any changesmade will not be saved to the memory.

    CAN address

    CAN address +1

    CAN address -1

    Enter

    Exit

    CAN address: 3

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    36/52

    Manual ALPHAWIND MF version 1.4 Page 36 of 52

    ALPHAWIND MF

    4.2.4.10 Dim group menuIf the instrument is used in a central dimming system of multiple instruments, each instrumentshould be assigned to a dim group. Each instrument can be assigned to one of the dim groups(max. 5 groups).

    It is recommended to assign all instruments connected to the central dimming system and thatare physically at the same distance of the user to the same dim group. A minimum lower limitvalue can be assigned to each group via the Dim limit menu. This means that it is NOTpossible to remotely dim this group below this set value.

    Possible dim groups:

    Figure 32: Example Dim groups

    In the example above, the minimum dim value of dim group 1 is set to 40%, and "dim group

    2" to 0%. If one of the instruments from "dim group 2" is dimmed from 100% to 0%, theinstruments from "dim group 1" will not go below the set 40%. The instruments in the overheadconsole will now remain easily readable to the user.

    The left and right buttons can be used to select the desired menu option. Activate theselected menu option by pressing the 'dim/menu' button.

    Dim group 1

    Dim group 2

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    37/52

    Manual ALPHAWIND MF version 1.4 Page 37 of 52

    ALPHAWIND MF

    Figure 33: Dim group menu

    The dim group number can be set with the options Dim group +1 and Dim group -1. Thedim group number can be increased or decreased by selecting either of these options and thenpressing the dim/menu button. The dim group number is displayed at the bottom of the display.Save the dim group number to the memory by selecting the Enter option and shortly pressingthe 'dim/menu' button. The instrument will now automatically return to the CAN settings menu.

    Select and activate the 'Exit' option in order to return to the CAN settings menu. Any changes

    made will not be saved to the memory.

    NOTE: The DIM group number can only be set to 1 or higher.

    Dim group

    Dim group +1

    Dim group -1

    Enter

    Exit

    Current group: 2

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    38/52

    Manual ALPHAWIND MF version 1.4 Page 38 of 52

    ALPHAWIND MF

    4.2.4.11 Dim limit menuVia the Dim limit value menu a lower/minimum limit value can be set to the instrument'sbacklight. The dim limit value is the lower limit value for dimming an instrument via thecentral dimming system. This means that it is NOT possible to central dim the instrument belowthis set value. If this value has been set to zero, the instrument can fully be dimmed. See also

    Dim Group menu.

    Figure 34: Dim limit menu

    Note: the set dim limit value only works on dimming via the central CAN bus dimsystem. An instrument that is dimmed individually (by means of the buttons) canalways be dimmed back to zero.

    The minimum dim value can be set using the options Dim limit +1, Dim limit +10, Dimlimit -1 and Dim limit -10 by using the left and right buttons and then the 'dim/menu' button.The current dim limit value is displayed at the bottom of the display: Value: xx%. If thedesired Dim limit value is set, it can be saved to the memory by selecting the Enter option andshortly pressing the 'dim/menu' button. The instrument will now automatically return to theCAN settings menu.

    Select and activate the 'Exit' option in order to return to the CAN settings menu. Any changesmade will not be saved to the memory.

    Dim limit

    Dim limit +1%

    Dim limit +10%

    Dim limit -1%Dim limit -10%

    Enter

    Exit Value: 30%

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    39/52

    Manual ALPHAWIND MF version 1.4 Page 39 of 52

    ALPHAWIND MF

    4.2.4.12 Offset menuThis submenu opens various menus that can be used to determine the offsets for the windsensor and the analogue pointer/indicator. An offset may be necessary because the frontend ofthe wind sensor does not completely match with the front of the ship.

    Figure 35: Offset menu

    The following submenus can be opened:

    Offset sensor menu (this is used to compensate the difference between the frontend of theship and the wind sensor's frontend)

    Offset pointer menu (this is used to compensate the mechanical difference between theinternal zero sensor and the analogue pointer/indicator)

    Reset all offsets menu (this is used to reset all offsets at once)

    NOTE:It is recommended to reset all offsets to zero via the Reset all offsets during the first start-up/commissioning. Then set the sensor offset. After this it is also possible to set the offsetpointer. This must be done according to the wind direction that is outputted from the sensor.

    The pointer offset must not be more that +/- 10 degrees.

    Offset menu

    Offset sensor

    Offset pointer

    Reset all offsets

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    40/52

    Manual ALPHAWIND MF version 1.4 Page 40 of 52

    ALPHAWIND MF

    4.2.4.13 Offset sensor menuThis offset needs to be adjusted first. This offset is used to compensate the difference betweenthe frontend of the ship and the wind sensor's frontend. Before doing so, it is wise to reset alloffsets to zero. See also Reset all offsets menu. Before adjusting the analogue wind sensor'soffset, a different operation needs to be done with regards to the digital NMEA sensor.

    The front of the analogue windsensor needs to be (temporarily) pointed to the ship's frontendduring this procedure. It is for instance necessary to fasten the wind flag with tape.

    Figure 36: Offset direction wind sensor

    The indicator will reach its final position if the ALPHAWIND MF's internal filter is full afterapproximately 30 seconds (max 40s). The indicator will now not or hardly move anymore. Thedifference between the zero point and the indicator is the offset that needs to be used. If theindicator is on the right side from the zero point, the offset should be positive. If the indicator ison the left side from the zero point, the offset should be negative.

    The current offset value can be found at the bottom of the screen, on the right side besides thetext Exit. The offset can be increased or decreased by selecting and activating the menu items

    +1 degree, +10 degrees, -1 degree of -10 degrees and then pressing the dim/menu

    button. In order to save the correct offset, select and activate the Enter menu item bypressing the dim/menu button. The selected offset value will now be saved in the instrument'smemory and applied for further use.

    Select and activate the 'Exit' option in order to return to the service menu. Any changes to theoffset will not be used, and not be saved.

    Offset direction

    +1 degree

    +10 degrees

    -1 degree

    -10 degrees

    Enter

    Exit Offset = 8

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    41/52

    Manual ALPHAWIND MF version 1.4 Page 41 of 52

    ALPHAWIND MF

    4.2.4.14 Offset pointer menuIt is possible that the analogue indicator has a slight fixed deviation (max. 10 degrees) inrelation to the wind direction due to mechanical intolerances. This fixed deviation can becorrected by adding an offset to the indicator. This can be done in the Offset pointer menu.

    When this menu is opened, the exact wind direction is digitally displayed at the bottom of thescreen. If the analogue display deviates from the digital display, correct this deviation by usingthe menu items + indicator or the - indicator.

    If the analogue indicator is too high, this can be corrected by selecting the - indicator and thencontinuously pressing and releasing the dim/menu button until the required offset is reached.Each time the dim/menu button is pressed, the analogue indicator will make a small step tothe right.If the analogue indicator is too low, this can be corrected by selecting the + indicator and thencontinuously pressing and releasing the dim/menu button until the required offset is reached.Each time the dim/menu button is pressed, the analogue indicator will make a small step tothe left.

    Figure 37: Offset pointer menu

    Select the menu item 'Enter' if there is no more difference between the analogue and digitalcourse. By pressing the dim/menu button shortly, the chosen offset will be saved in theinstruments memory and applied for further use. The instrument will now automatically returnto the service menu.

    By selecting and activating the Exit item the instrument will return to the service menu. Anyalterations to the analogue indicator will not be saved.

    Offset pointer

    + indicator

    - indicator

    Enter

    Exit

    Wind dir= 1

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    42/52

    Manual ALPHAWIND MF version 1.4 Page 42 of 52

    ALPHAWIND MF

    4.2.4.15 Reset all offsets menuThis menu is used to reset all offsets to zero at once. When opening this menu, the item Resetall offsets to 0 is automatically selected. By shortly pressing the dim/menu button, both thewind sensor offset as the pointer offset will be reset to 0. These values will be saved andapplied for further use.

    Figure 38: Reset all offsets menu

    By selecting and activating the Exit item the instrument will return to the service menu. Thechanges will not be saved.

    Reset offsets

    Reset all offsets

    To 0

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    43/52

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    44/52

    Manual ALPHAWIND MF version 1.4 Page 44 of 52

    ALPHAWIND MF

    Factory settings menu

    This menu can be used to restore the instrument to factory settings. There are only twopossible options in this menu. The option reset factory settings has been automaticallyselected. By activating this option the ALPHAWIND MF will be reset with the following settings:

    Backlight colour : White Background on/off : ON Language : English Offset pointer : 0 degrees Offset wind direction : 0 degrees Sensor type : Analogue Central dimming : OFF CAN bus Group number : 1 CAN bus ID : 0 CAN bus min dim value : 0

    Figure 40: Factory settings menu

    By selecting and activating the Exit item, the instrument will automatically return to the

    service menu. Now, nothing has been changed to the instrument's settings.

    Factory settings

    Reset factory

    setting

    Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    45/52

    Manual ALPHAWIND MF version 1.4 Page 45 of 52

    ALPHAWIND MF

    5 SCHEMATIC COMPOSITION OF THE MENU STRUCTUREThe menu structure of the ALPHAWIND MF:

    Main menu

    Backlight menu

    Red Green White Central dim menu

    Central dim ON Central dim OFF Exit

    Background menu Background ON Background OFF Exit

    Exit

    Language menu Nederlands English

    Deutsch Exit

    Unit settings menu Bft Knots m/s Reset max wind Exit

    Service menu NMEA LOG menu or Analogue LOG menu

    Time-out= x.x Analogue= x.x Error_Cntr = x Pulse_Wndspd=x.x F_update = x F_update = x Enter Enter

    CAN settings

    CAN address Dim group Dim Limit value Exit CAN address +1 * Dim group +1 * Limit value +1% CAN address +1 * Dim group +1 * Limit value +10% Enter * Enter * Limit value -1% Exit * Exit * Limit value -10%

    * Enter* Exit

    Offset menu Offset sensor Offset pointer Reset all offsets Exit

    +1 degree * + Indicator * Reset all offsets +10 degree * - Indicator * Exit 1 degree * Enter 10 degree * Exit Enter Exit Offset = x

    Sensor type Analogue sensor Digital (NMEA) sensor Exit

    Factory settings menu Reset factory settings Exit

    Exit Exit

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    46/52

    Manual ALPHAWIND MF version 1.4 Page 46 of 52

    ALPHAWIND MF

    6 FIRMWARE REVISIONThis manual is in accordance with software version V3.3.

    7 TROUBLESHOOTING

    8 TECHNISCHE SPECIFICATIONS

    Electrical:

    Parameter Value Comments

    Operating voltage 10-40 Volts DC voltage

    Power consumption 30mA turned off

    0.3A turned onReverse battery protection Yes Fuse does defect

    Input(s) 1x RS485/422

    EMC approved IEC60945

    Mechanical:

    Parameter Value Comments

    Size 161x181x123mm

    Weight 1.5 KgIP value IP65 Only applies to the front ofthe instrument

    Environmental:

    Parameter Value Comments

    Operation temperature 0C to +50C

    Storage temperature -10C to +50C

    9 TECHNICAL SUPPORTPlease contact Alphatron Marine B.V. for technical support regarding the ALPHAWIND MF:

    Alphatron Marine BVSchaardijk 23

    3063NH, RotterdamP.O. Box 21003The Netherlands

    Tel: 0031(0)10 4534000

    Fax: 0031(0)10 [email protected]

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    47/52

    Manual ALPHAWIND MF version 1.4 Page 47 of 52

    ALPHAWIND MF

    10 ALPHATRON Dealers Deep-sea (Authorized)

    FRANCE

    Etna S.A.31 Rue des Ponts76620 Le Havre

    Tel. + 33 2 355 460 60Fax. + 33 2 355 460 59E-mail : [email protected]: www.etna.fr

    GERMANY

    Alphatron Marine Deutschland GmbHNienhfener Str. 29-3725421 Pinneberg

    Tel.: +49-(0)4101-203771-00Fax.: +49-(0)4101-203771-1124 h Service: +49-(0)15120377100E-Mail: [email protected]: www.alphatron-deutschland.de

    NORWAY

    ProNav ASFiskarvik Maritime Senter4370 EGERSUNDTel. + 47 514 94 300Fax.+ 47 514 92 100E-mail : [email protected]: www.pronav.no

    SPAIN

    Crame S.A.C/Lanzarote 1428700San Sebastian de los ReyesTel. + 34 91 658 65 08Fax. + 34 91 654 96 4424h Service: + 34 902 218750E-mail : [email protected]: www.crame.es

    SINGAPORE

    Alphatron Marine Systems Pte. LtdHO LEE Industrial Development59 S, Tuas South Avenue637418Tel.E-mail : [email protected]: www.alphatronmarine.com

    INDIA

    Elektronik LabR/13 Navroz BaugLalbaug MUMBAI 400012Tel. + 91 22 247 151 15Fax. + 91 22 247 104 44

    E-mail: [email protected]: www.elektroniklab.com

    SOUTH AFRICA

    SMD Telecommunications CC53 Paarden Eiland Road7405PAARDEN EILAND CAPE TOWNTel.: + 27 - 21 511 0556Fax: + 27 - 21 511 288624h Service: + 34 902 218750E-mail : [email protected]: www.smd-marine.com

    BRAZIL

    JRC Do Brasil

    Av. Almirante Barroso63 GR. 309 - CentroRJ CEP. 20036-900Tel. + 55 21 2220 8121Fax. + 55 21 2240 6324E-mail :[email protected]: www.jrcbrasil.com.br

    CHILI

    Selmar Ltda.

    Avda.Coln 3140TalcahuanoTel. + 56 41 2920800Fax. + 56 41 2920803E-mail :[email protected]: www.selmarchile.com

    ITALY

    ITS RadiomarittimiP.zza Luigi Sturzo, 15I-00144 RomeTel. +39 06.54515299Fax. +39 06.65400100

    E-mail : [email protected]: www. radiomarittimi.it

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    48/52

    Manual ALPHAWIND MF version 1.4 Page 48 of 52

    ALPHAWIND MF

    11 ALPHATRON Dealers Inland Shipping (Authorized)

    For dealers in other countries, see:www.alphatronmarine.nl

    UNITED KINGDOM

    Selex Communications LtdLambda HouseChristopher Martin Road

    BASILDONESSEX SS14 3ELTel. + 44 (0) 1268 82 3400Fax.+ 44 (0) 1268 82 349324h Service: + 34 902 218750E-mail : Internet: www.selex-comms.com

    UNITED ARAB EMIRATES

    Elcome International L.L.C.Al Jadaf Dockyard DY159P.O. Box 1788

    DUBAITel. + 971 4 4049100Fax. + 971 4 049200E-mail: [email protected]: www.elcome.ae

    FRANCE

    Avon Communications S.A.Village d'entreprise de St HenRue Anne Gacon BP 147Batiment 3- lot 1413322 MARSEILLE CEDEX 16Tel. 0033-495069350E-mail : [email protected]

    FRANCE

    SIECMIAgence de Boulogne s/Mer9/10 Rue Huret LagacheTerrasse des Batiments de mare62200 BOULOGNE SUR MERTel. 0033-298975086E-mail : [email protected]

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    49/52

    Manual ALPHAWIND MF version 1.4 Page 49 of 52

    ALPHAWIND MF

    12 Appendix 1: Mounting frame

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    50/52

    Manual ALPHAWIND MF version 1.4 Page 50 of 52

    ALPHAWIND MF

    13 Appendix 2: Instrument dimensions

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    51/52

    Manual ALPHAWIND MF version 1.4 Page 51 of 52

    ALPHAWIND MF

    14 Appendix 3: Complete connection diagram

  • 7/22/2019 Installation & Operational Manual ALPHAWIND MF ENG v1.4 A4.pdf

    52/52

    ALPHAWIND MF

    15 NOTES: