    USER MAUAL FOR : L C R BOARD

    AIM: - To study the series and parallel resonance circuit and to find frequency and quality factor.

    MICRO BOARD COSISTS OF: -Set of resistors, Capacitors, Inductors and Milli ammeter.R = 150 R = 150 R = 330

    C = 0.01 C = 0.1 F C = 0.22 FL = 2.5mH L = 5mH L = 7.5mH

    PROCEDURE: -

    SERIES RESOACE: -

    1. Connect the circuit as shown in the circuit diagram.2. Apply input signal using signal generator. The output should be 10V only.3. Take the output across the resistor and feed it to Ammeter input sockets.4. Vary the frequency till the Ammeter records a sharp rise and fall, adjust the signal such

    that the Ammeter deflection is the maximum possible. This is the resonant frequency of

    the connected combination of the circuit.5. Adjust the signal generator amplitude such that to get full-scale deflection. In Ammeter

    now reduce the frequency till the deflection falls considerably. Then increase thefrequency in regular intervals & note down the Ammeter readings.

    6. Plot a graph between the meter deflection divisions and frequency.7. Repeat the procedure using different combinations of L, C & R and study how Q is

    affected. Also study how Resonant Frequency depends upon different combination ofL.C.R.

    PARALLEL RESOACE: -

    1. Connect the circuit as per the circuit diagram.2. Apply input signal, from a reliable signal generator. The output should be 10V only.3. Take the output across the tank circuit and connect to Ammeter input sockets.4. Vary the frequency till the Ammeter records sharp fall. Adjust the signal such that the

    deflection falls down considerably. Then increase the frequency in regular intervals andnote down the deflection.

    5. Adjust the signal generators amplitude such that, to get full-scale deflection. Now reducethe frequency till the deflection falls down considerably. Then increase the frequency inregular intervals & note down the deflection.

    6. Plot graph between the meter deflection divisions and frequency.7. Repeat the procedure for different values of R and study how Q is affected. Also study

    how resonant frequency depends on different combinations of L.C.R.

    CALCULATIOS: -

    For series circuit Z is minimum at Resonance.

    Resonance frequency of series circuit is-

    1fo = Zo = R + Ro

    2 LC

    Io = E

    R + RoEo = RIo

    Ro is the resistance of the coil.

    1

    12

    2

    2

    33

    3

  • 7/30/2019 LCR Board

    2/2

    2

    foQo = ( = f2 f1)

    f2 is the point beyond the fo (at the point Eo/2)

    f1 is the point before fo (at the point Eo/2)

    LWoQ is also equal to =

    R + Ro

    For parallel circuit Z is maximum at resonance.

    1

    fo =2 LC

    LZo = or Qo =L Wo

    CRo

    EZoEo = Izo =

    (R + Zo)

    foQo = (=f2 - f1 as like the case of series circuit)

    CIRCUIT DIAGRAM: -

    L C R SERIES RESOACE GRAPH: -

    L C R PARALLEL RESOACE GRAPH: -

    R

    L C

    Im

    ImI

    2

    f1 f0 f2FREQUECY

    R

    A

    +

    A

    -

    L

    CI

    f0

    FREQUECY

    SIGALGEERATOR

    SIGAL

    GEERATOR