NIEDERSPANNUNGSANTRIEB FÜR ZAHNSTANGEN...

13
ISTRUZIONI D’USO E DI INSTALLAZIONE INSTALLATION AND USER’S MANUAL INSTRUCTIONS D’UTILISATION ET D’INSTALLATION INSTALLATIONS-UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION INSTALLATIEVOORSCHRIFTEN 8 027908 351258 ATTUATORE IN BASSA TENSIONE PER CANCELLI SCORREVOLI A CREMAGLIERA LOW-VOLTAGE ACTUATOR FOR RACK SLIDING GATES ACTIONNEUR A BASSE TENSION POUR PORTAILS COULISSANTS A CREMAILLERE NIEDERSPANNUNGSANTRIEB FÜR ZAHNSTANGEN-SCHIEBETORE SERVOMOTOR DE BAJA TENSION PARA CANCELAS CORREDERAS DE CREMALLERA LAAGSPANNINGSACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung! Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig! DEIMOS BT + QSC D MA DEIMOS BT + QSC D MA D811343 00100_03 25-01-11

Transcript of NIEDERSPANNUNGSANTRIEB FÜR ZAHNSTANGEN...

ISTR

UZI

ON

I D’U

SO E

DI I

NST

ALL

AZI

ON

EIN

STA

LLA

TIO

N A

ND

USE

R’S

MA

NU

AL

INST

RUCT

ION

S D

’UTI

LISA

TIO

N E

T D

’INST

ALL

ATI

ON

INST

ALL

ATI

ON

S-U

ND

GEB

RAU

CHSA

NLE

ITU

NG

INST

RUCC

ION

ES D

E U

SO Y

DE

INST

ALA

CIO

NIN

STA

LLAT

IEVO

ORS

CHRI

FTEN

8 027908 3 5 1 2 5 8

ATTUATORE IN BASSA TENSIONE PER CANCELLI SCORREVOLI A CREMAGLIERALOW-VOLTAGE ACTUATOR FOR RACK SLIDING GATESACTIONNEUR A BASSE TENSION POUR PORTAILS COULISSANTS A CREMAILLERENIEDERSPANNUNGSANTRIEB FÜR ZAHNSTANGEN-SCHIEBETORESERVOMOTOR DE BAJA TENSION PARA CANCELAS CORREDERAS DE CREMALLERALAAGSPANNINGSACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL

Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung! Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig!

DEI

MOS

BT

+ Q

SC D

MA

DEI

MO

S B

T +

QS

C D

MA

D81

1343

001

00_0

3 25

-01-

11

3x1mm2

3x1.5mm2

2x0.75mm2

3x1.5mm2RG58

3x1.5mm 2

3x1.5mm 2

5x0,75mm2

2x1.5mm2

Predisposizione fissaggio motore, Preparation for motor mounting,Aménagement fixation moteur, Vorbereitung Motorbefestigung,Disposición fijación del motor, Voorbereiding bevestiging motor.

25mm + “X”

“X”= Cremagliera, Rack, Crémaillère, Zahnstange, Cremallera, Tandheugel

Montaggio motore, Mounting the motor, Montage moteur,Montage Motor, Montaje del motor, Montage motor.

Montaggio accessori trasmissione, Mounting drive accessories,Montage accessoires transmission, Montage Antriebszubehör,Montaje de accesorios transmisión, Montage accessoires overbrenging.

Fissaggio staffe finecorsa (dx e sx), Fastening limit switch brackets (RH/LH),Fixation étriers fin de course (drt et gch), Befestigung Bügel Anschläge (rechts und links),Fijación abrazaderas final de carrera (der. e izq.),Bevestiging stangen aanslag (rechts en links).

Y

Y

Collegamento morsettiera, Terminal board wiring,Connexion plaque à bornes, Anschluss Klemmleiste,Conexión tablero de bornes, Aansluiting aansluitkast.

> 10mm

> 25mm A

C

E

B

D

F

D1

PREDISPOSIZIONE TUBI, TUBE ARRANGEMENT,PRÉDISPOSITION DES TUYAUX, VORBEREITUNG DER LEITUNGEN,DISPOSICIÓN DE TUBOS, VOORBEREIDING LEIDINGEN.

INSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDESCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE

2 - DEIMOS BT-MA

D81

1343

001

00_0

3

JP3

24 12 1321

COM

PHO

T

24V

~

Rx 1 Tx 112345

12

Connection of 1 pair of non-tested photocells

Anschluss von einem Paar nicht überprüften FotozellenConexión de 1 par fotocélulas no comprobadasAansluiting van 1 paar fotocellen anders dan “trusted device”

Display + tasti programmazioneDisplay + programming keys

Display + ProgrammierungstastenPantalla + botones programaciónDisplay + programmeringstoetsen

LOGICA test fotocellule OFF / Photocell test LOGIC OFFLOGIQUE essai photocellules Désactivée / LOGIK Test Fotozellen OFFLÓGICA prueba fotocélulas OFF / LOGICA test fotocellen OFF

N L

12

34

56

78

910

1112

1314

1516

1718

1920

2122

2324

2526

31 32 33 34

JP2

JP3

24V

~23

0V~

F G

M

NO

NO

FAULT

COM

PED

COM

NC

SWCNCSWO

24V~

0V

ANT

Grig

io-G

rey-

Gris-

Grau

-Gris

-Grij

sGr

igio

-Gre

y-Gr

is-Gr

au-G

ris-G

rijs

A

B

C

D

E

SCA/2°CH

COM

NO

NC

NO

NC

NC

STARTCLOSE

STOP

PHOT

BAR

OPEN

Connettore programmatore palmare,Palmtop programmer connector, Connecteur programmateur de poche,Steckverbinder Palmtop-Programmierer,Conector del programador de bolsillo,Connector programmeerbare palmtop.

T 0,62 A

T 1 A

Con

net

tore

sch

eda

opzi

onal

e O

pti

onal

boa

rd c

onn

ecto

rC

onn

ecte

ur c

arte

facu

ltat

ive

Stec

kver

bin

der

Zus

atzk

arte

C

onec

tor d

e la

tarj

eta

opci

onal

C

onn

ecto

r op

tion

ele

kaar

t

G

H

I J

J1

MEMORIZZAZIONE RADIOCOMANDOMEMORIZING REMOTE CONTROLSMÉMORISATION RADIOCOMMANDEABSPEICHERUNG DER FERNBEDIENUNG MEMORIZACION DEL RADIOMANDO GEHEUGENOPSLAG AFSTANDSBEDIENING

RADIO

x 2

x 2OK

PArAM

OK

OK

Fine

- End - Fin

tasto nascosto-hidden button-touche cachee-verst.taste

rilascia-release-relache - -loslassen-suelte

tasto desiderato-desider button touche desiree-gevue taste-tecla deseada

Agg.start - Adjouter start - zufuegstart - anad start

+ x 3

+

OK

8888

+

OK8888

REGOLAZIONE AUTOSET, ADJUSTING AUTOSET, REGLAGE AUTOSET, EINSTELLUNG AUTOSET, REGULACION AUTOSET,AFSTELLING AUTOSET.

REGOLAZIONE VELOCITA’ RALLENTAMENTOADJUSTING SLOW-DOWN SPEED RÉGLAGE VITESSE RALENTISSEMENTEINSTELLUNG GESCHWINDIGKEIT VERLANGSAMUNGREGULACIÓN VELOCIDAD DECELERACIÓNAFSTELLING SNELHEID VERTRAGING

AUTO OPEN

OK

OK

autoset

. . . . . . . .

x 5

x 2OK

PArAM

+

CLOSE

AUTO CLOSE

AUTO OPEN

AUTO CLOSE

x 3OK

vel. rall

tca

vel. rall

prg

fine-end-fin

OK

OK

x 7

x 2 +

+

OK8888

+

1

JP9

13 12 14

SCA

II° CH

15

JP9

14 15

24 V

~

VSAFE ~(+)

VSAFE ~(-)

24V ~(+)

24V ~(-)

25W max.

ERRORE!ERROR!ERREUR!FEHLER!ERROR!FOUT!

ITALIA

NO

ENG

LISHFRA

NÇA

ISD

EUTSCH

ESPAÑ

OL

NEDERLANDS

DEIMOS BT-MA - 3

D81

1343

001

00_0

3

K

NM

O P

CFZ CP

37

30

12

28

22

22

CVZ

2860

640

NO OK

Q

R

P1P2

S

L

249131

118160

265

122

50

22

43

O1

8888

>100

25

50>2

5

2mm

4 - DEIMOS BT-MA

D81

1343

001

00_0

3

U

COM

NC

PHO

T

STOP

BAR2

3132

3334

26 25 24 23 22

21-23 SLAVE21-24 SLAVE

21 20 19 18 17 16 15 11 10 9 8 6 5 4 3 2 1714 13 12

JP2JP3

(-)(+) (-)(+)

M

COM

NC

SWC

NCSW

O

24V~

0V

ABCDE

T 0,62 A

T 1 A

T

8888

Programmeerbare Universele Palmtop

SCHEDA DI ESPANSIONEEXPANSION BOARDCARTE EXPANSIONERWEITERUNGSKARTETARJETA DE EXPANSIÓNUITBREIDINGSKAART

UNIDA

RXRXTXTX

3132

3334

JP2JP3

(-)(+) (-)(+)

M

NC NCSW

O

SWC

COM

24V~0V

ABCDE

T 0,62 A

T 1 A

24V25W

Max

AN

T

SCA/2°CH

24 V~

+

24 V~

-FAULT

PED

COM

COM

NO

NO

NO

NC

NO

NC

NC

STARTCLOSE

STOPPHOT

BAR1

OPEN

SCS1

QSC-DM1 (MASTER)

QSC-DM2 (SLAVE)

TX1 (PHOT)RX1 (PHOT) BAR2 BAR1

TX2 (PHOT) RX2 (PHOT)

M2SLAVE

M1MASTER

zone=128master=ON

zone=128master=OFF

RXRXTXTX

26 25 24 23 22 21 20 19 18 17 16 15 11 10 9 8 6 5 4 3 2 1714 13 12

FAULT

COMN

O

V Safe -

V Safe +

24 V~

+

24 V~

-

V Safe -

V Safe +

lasciare ponticellatileave jumperedlaissez-la pontéeüberbrückt lassendejar puenteadobrug niet verwijderen

DEIMOS BT-MA - 5

D81

1343

001

00_0

3

VFOTOCELLULEFOTOZELLEN

PHOTOCELLSFOTOCÉLULAS

PHOTOCELLULESFOTOCELLEN

COSTELEISTEN

SAFETY EDGESCANTOS

LINTEAUXRANDEN

12

12345

1716

131221

24

TX1 RX1

1-PHOT

12

12345

1716

131221

24

TX1 RX1

181-PHOT

1-BAR

Bar 1123456

131221

2517

18

1-BAR

Bar 1123456

131221

2517

2-BAR

3-BAR

4-BAR

12

12345

1716

1312

2124

TX1 RX1

2-PHOT

3-PHOT

4-PHOT

12

12345

1716

1312

1821

TX2 RX2

12

12345

1716

1312

2124

TX1 RX1

12

12345

1716

1312

2-SCS1-MA1-SCS1-MA

3-SCS1-MA

TX2 RX2

12

12345

1716

1312

1821

TX3 RX3

2-SCS1-MA

3-SCS1-MA5-SCS1-MA4-SCS1-MA

6-SCS1-MA

1-SCS1-MA

12

12345

1716

1312

2124

TX1 RX1

12

12345

1716

1312TX2 RX2

12

12345

1716

1312TX3 RX3

12

12345

1716

1312

1821

TX4 RX4

Bar 1123456

1312

212517

Bar 2123456

1312

182117

Bar 1123456

1312

212517

Bar 2123456

1312

2-SCS1-MA1-SCS1-MA

2-SCS1-MA1-SCS1-MA

17

Bar 3123456

1312

182117

3-SCS1-MA

Bar 1123456

1312

212517

Bar 2123456

1312

17

Bar 4123456

1312

182117

Bar 3123456

1312

5-SCS1-MA3-SCS1-MA

6-SCS1-MA

4-SCS1-MA17

TE

ST

BA

R =

ON

FA

ULT

/PH

OT

= O

FF

FA

ULT

/PH

OT

= O

N

FAU

LT/P

HO

T=O

NFA

ULT

/PH

OT=

OFF

FAU

LT/P

HO

T=O

FF

26 25 24 23 22 21 20 19 18

COM

FAULT

COM

BAR

PHO

T

Vsafe +

Vsafe -

24V ~(+)

24V ~(-)

17 16 15 14 13 12

Combinazioni possibili, Possible combinations, Combinaisons possibiles, Mögliche Kombinationen, Combinaciones posibles, Mogelijke combinaties

TE

ST

PH

OT

= O

N

1

1 2 BBBB

345

ACDE

111

2

3

4

5

A

B

C

D

E

FOTOCELLULEFOTOZELLENPHOTOCELLS

FOTOCÉLULASPHOTOCELLULESFOTOCELLEN

COSTELEISTENSAFETY EDGES

CANTOSLINTEAUXRANDEN

FAULT/PHOT= ONFAULT/PHOT= OFFFOTOCELLULEFOTOZELLENPHOTOCELLS

FOTOCÉLULASPHOTOCELLULESFOTOCELLEN

COSTELEISTENSAFETY EDGES

CANTOSLINTEAUXRANDEN

6 - DEIMOS BT-MA

D81

1343

001

00_0

3

param. 1

param. 2

param. . . .

logic. 1logic

logic. 2

logic. . . .

PRG

ITA

FRA

DEU

ENG

esp

OK

OK

OK

OK

OK

- +

- +

- +

- +

add. start hidden button release ok 01desired button

PRG.

read

erase 64

COD RX 1A9C OK 22FD OK 01 OK

Add. 2ch

+/-

01 t1

See PARAMETERS MENU

See LOGIC MENU

See RADIO MENU

radio

ACCESS TO MENUS Fig. 1

end

end

end

end

end

end

language

default

autoset

ok 01

Control unit software versionN. total manoeuvres (x 100)

N. manoeuvres since latest maintenance (x 100)

N. radio control devices memorised

Press the OK key

hidden button release desired button

v

Exit Menù

Confirm/Switch on display

Scroll up

Scroll down

DIAGNOSTICS and WARNINGSDIAGNOSTICS

CODE DESCRIPTION NOTES

ped pedestrian input activatedstrt START input activatedstop STOP input activatedphot attivazione ingresso PHOTbar SAFETY EDGE input activated

flttested photocell FAULT input activated

cls CLOSE input activatedopen OPEN input activated

swoopening limit switch input activated

swc closing limit switch input activated

orhigh torque during slow-down in AUTOSET mode

Use a lower slow-down and check mo-vement and smooth operation of leaf

th software thermal cutout activated allow automated device to coolamp reverse due to obstacle make sure movement is not hindered

Er01 photocell test anomaly check photocell connection and/or parameter/logic settings

Er02 safety edge test anomaly check safety edge connection and/or parameter/logic settings

Er1X * hardware anomaly check connections to motor

Er5X * communication anomalycheck connection with accessory devices and/or expansion boards or serial-connected devices

* X = 0,1,…,9,A,B,C,D,E,F35.40

Set torque threshold Maximum instantaneous motor torque

12 - DEIMOS BT-MA

D81

1343

001

00_0

3

ENG

LISH

WARNING! Important safety instructions. Carefully read and comply with the Warnings booklet and Instruction booklet that come with the product as incorrect installation can cause injury to people and animals and damage to property. They contain important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference.

1) GENERAL SAFETYWARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things.- The units making up the machine and its installation must meet the requirements

of the following European Directives: 2004/108/EEC, 2006/95/EEC, 98/37/EEC, 89/106/EEC and later amendments. For all countries outside the EEC, it is advisable to comply with the above-mentioned standards, in addition to any national standards in force, to achieve a good level of safety.

- The Firm disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated he-rein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.

- Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.

- Before performing installation, remove any cables or chains that are not nee-ded and disable any equipment that is not required for installation purposes. Also check that the door/gate is in a good state of mechanical repair, is cor-rectly balanced and opens and closes as it should do.

- Do not install the product in an explosive atmosphere.- Disconnect the electricity supply before performing any work on the system.

Also disconnect buffer batteries, if any are connected.- Have the automated system’s mains power supply fitted with a switch or om-

nipolar thermal-magnetic circuit breaker with a contact separation of at least 3.5 mm.

- Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at 0.03A.

- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal.

- Installation must be carried out using safety devices and controls that meet standard EN 12978.

- Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of crushing, dragging and shearing hazards.

- The motor cannot be installed on panels incorporating doors (unless the mo-tor can be activated when the door is open)

- If the automated device is installed at a height of less than 2.5 m or is accessi-ble, the electrical and mechanical parts must be suitably protected.

- Any fixed controls must be installed within sight of the door but away from moving parts. Unless the control is key operated, it must be installed at a height of at least 1.5 m and in a place where it cannot be reached by the public

- Apply at least one warning light (flashing light) in a visible position, and also attach a Warning sign to the structure.

- If there are no instructions already, attach a label near the operating device, in a permanent fashion, with information on how to operate the manual rele-ase.

- Make sure that nothing can be crushed between the guided part and sur-rounding fixed parts during the door’s operation

- Once installation is complete, make sure the motor has the right settings and that the safety and release systems are working properly.

- Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automa-ted system if parts from other manufacturers are used.

- Do not make any modifications to the automated system’s components un-less explicitly authorized by the Firm.

- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accor-dance with the provisions of the laws in force. Keep nylon bags and polystyre-ne out of reach of children.

- Anything which is not expressly provided for in the present instructions, is not allowed.

- Instruct the product user about the control systems provided and the manual opening operation in case of emergency.

Warning! For connection to the mains power supply, use a multicore cable with a cross-section of at least 4x1.5mm2 of the kind provided for by the regulations mentioned above (by way of example, type H05 VV-F cable can be used with a cross-section of 4x1.5mm2). To connect auxiliary equipment, use wires with a cross-section of at least 0,75 mm2.Have an omnipolar circuit breaker installed with a contact separation of at least 3 mm and featuring overload protection, suitable for cutting the automated device off from the mains.Only use pushbuttons with a capacity of 10A-250V or more.

The cables must be held in position using an extra fixing device in the prox-imity of the terminals, e.g. with cable clamps.Also add more clips to the limit device wires, to the transformer primary or secondary wires, and to the wires connected to the printed circuit. During installation, the power supply cable must be stripped in order for the earthing wire to be connected to the appropriate terminal, but the active

wires must be left as short as possible. The earthing wire must be the last to stretch in the case where the cable fixing device becomes loose.

WARNING: extremely low safety voltage cables must be phisically separated from low voltage cables.

Access to the electrical compartment or to limit switches must be allowed to skilled personnel only.

Setting sensitivity incorrectly can result in damage to property and injury to people and animals.

Compliance with current safety rules with regard to people, animals and property must be assured at all times and, more specifically, measures must be taken to avoid risks of injury due to crushing, in the area where the pinion and rack mesh, and any other mechanical hazards. All critical points must be protected by safety devices in accordance with the provisions of the regulations in force.

CHECKING THE AUTOMATED DEVICEBefore the automated device is finally put into operation, perform the following checks meticulously:• Make sure all components are fastened securely.• Check the correct functioning of all safety devices (limit microswitches, pho-

tocells, sensitive edges etc.).• Make sure that the anti-crush system stops the door within the limits provided

for by the standards in force.• Check the emergency operation control device.• Check the opening and closing operations with the control devices in use.• Check the standard and customised electronic functioning logic.

MAINTENANCEWARNING: before opening the door, the spring must be unloaded (vertical boom). WARNING: Before carrying out any maintenance to the installation, disconnect the mains power supply. The following points need checking and maintenance:- Photocell optics. Clean occasionally.- Electric edge. Carry out a periodical manual check to ensure that the edge

stops the bar in case of obstacles.- Dismantle the gearmotor and replace the lubricating grease every two

years.- When any operational malfunction is found, and not resolved, disconnect the

mains power supply and request the assistance of a specialised technician (installer). When the operator is out of order, activate the emergency release (see Fig. 2), if necessary, so as to release the manual boom opening and closing operations.

SCRAPPINGMaterials must be disposed of in conformity with the current regulations. In case of scrapping, the automation devices do not entail any particular risks or danger. In case of recovered materials, these should be sorted out by type (electrical components, copper, aluminium, plastic etc.).

DISMANTLINGWhen the automation system is disassembled to be reassembled on another site, proceed as follows:- Disconnect the power supply and the entire electrical installation.- Remove the actuator from its fixing base.- Disassemble all the installation components.- In the case where some of the components cannot be removed or are dama-

ged, they must be replaced.

INSTALLATION MANUAL

Correct controller operation is only ensured when the data contained in the present manual are observed. The Company is not to be held respon-sible for any damage resulting from failure to observe the installation standards and the instructions contained in the present manual.The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product fea-tures unchanged, at any time and without undertaking to update the present publication.

DEIMOS BT-MA - 13

D81

1343

001

00_0

3

INSTALLATION MANUAL

1) FOREWORDThe DEIMOS BT-MA actuator is highly versatile in terms of installation options due to the extremely low position of the pinion, the actuator’s compact nature and the height and depth adjustment features it offers. The adjustable electronic torque limiter provides anti-crush safety. Manual emergency operation is extremely easy to perform using just a knob. Stopping at end of travel is controlled by electromechanical microswitches.The built-in control panel controls the start relays and safety devices (photocells, safety edge) each time before performing any operation.

2) TECHNICAL SPECIFICATIONS

MOTOR

Power supply single-phase 230V ±10%, 50Hz (*)

Motor 24V

Power input 70W

Max. current demand 0,5A (230V~) - 1A (110V~)

Pinion module 4mm (14 teeth)

Leaf speed 12m/min

Max. leaf weight 5000N (≈500kg)

Max. torque 20Nm

Impact reaction Electronic torque limiter

Lubrication Lifetime greased

Manual operation Knob-operated mechanical release

Type of use intensive

Buffer batteries (optional extras) Two 12V 1.2Ah batteries

Environmental conditions from -15°C to +40°C

Protection rating IP24

Noise level <70dBA

Operator weight 7kg (≈70N)

Dimensions See Fig. K

CONTROL UNIT

Accessories power supply 24V ~ (180 mA)

Built-in Rolling-Code radio-receiver frequency 433.92MHz

Automatic closing time range 0 to 120s

Work time max. 2 mins.

Pedestrian opening time fixed 7s

Reverse pause approx. 1s

Setting of parameters and options Universal handheld programmer/LCD display

N° of combinations 4 billion

Max. n° of remotes that can be me-morized

63

(*) Special supply voltages to order.

Usable transmitter versions:All ROLLING CODE transmitters compatible with

3) TUBE ARRANGEMENT Fig.AInstall the electrical system referring to the standards in force for electrical systems CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.

4) PREPARATION FOR MOTOR MOUNTING FIG.B• Make a hole in the ground to accommodate the concrete pad, with anchors

embedded in the base plate for fastening the gearbox assembly, keeping to the distances featured in FIG.B.

• To keep the base plate in the right position during installation, it may be useful to weld two iron plates under the track to which the anchors can then be welded (FIG.M).

5) MOUNTING THE MOTOR FIG.C

6) MOUNTING DRIVE ACCESSORIES FIG.D-D1

7) RACK CENTRING WITH RESPECT TO PINION FIG.N-O1-PDANGER - Welding must be performed by a competent person issued with the necessary personal protective equipment as prescribed by the

safety rules in force FIG.O.

8) FASTENING LIMIT SWITCH BRACKETS FIG.E

9) STOPS FIG.QDANGER - The gate must be fitted with mechanical stops to halt its travel both when opening and closing, thus preventing the gate from

coming off the top guide. Said stops must be fastened firmly to the ground, a few centimetres beyond the electric stop point.

10) MANUAL RELEASE (See USER GUIDE -FIG.2-).Warning Do not JERK the gate open and closed, instead push it GENTLY to the end of its travel.

----------------------------------------------------------11) TERMINAL BOARD WIRING Fig. F-GOnce suitable electric cables have been run through the raceways and the auto-mated device’s various components have been fastened at the predetermined points, the next step is to connect them as directed and illustrated in the diagrams contained in the relevant instruction manuals. Connect the live, neutral and earth wire (compulsory). The mains cable must be clamped in the relevant cable gland (FIG.R-ref.P1), and the accessories’ wires in the cable gland (FIG.R-ref.P2), while the earth wire with the yellow/green-coloured sheath must be connected in the relevant terminal (FIG.R-ref.S).

TERMINAL DESCRIPTION

1-2 Motor connection. WARNING - If opening direction is not correct, swap wires over.

3-4 24V transformer secondary winding.

5-6Closing limit switch SWC (5 Black common - 6 Red).

WARNING - If opening direction is not correct, swap opening and closing limit switch wires over.

5-7Opening limit switch SWO (5 Black common -7 Brown).

WARNING - If opening direction is not correct, swap opening and closing limit switch wires over.

8-9 Flashing light 24V max. 25W.

10-11

Antenna (10 signal - 11 braiding). Use an antenna tuned to 433MHz.Use RG58 coax cable to connect the Antenna and Receiver.Metal bodies close to the antenna can interfere with radio recep-tion. If the transmitter’s range is limited, move the antenna to a more suitable position.

12-13Accessories power supply:24 V operation with mains power on.24 V (12-,13+) operation with no mains power and optional buffer battery kit. Mod. SB BAT.

14-15Free contact (NO). Gate Open Light SCA (24V max. 3W) or 2nd radio channel output (FIG.G-ref.1). This option can be set via the “logic menu”.

16-17

Safety device power supply output (photocell transmitter and safety edge transmitter). N.B.: output active only during operating cycle. 24 V Vsafe operation with mains power on.24 V (16 -,17+) Vsafe operation with no mains power and optional buffer battery kit. Mod. SB BAT.

18-19 FAULT safety devices input.

19-20Pedestrian control button PED (NO) Opens the gate for a period of 5 seconds with the set logic modes(3 or 4 steps).

21-22 START/CLOSE control button and key-operated selector (NO).This option can be set via the “logic menu”.

21-23STOP control button (NC). Whatever the case, stops the automa-ted device until a new start command is given. If not used, leave jumpered.

21-24 PHOT photocell input. If not used, leave jumpered.

21-25Safety edge contact input BAR (NC). When tripped, the gate stops and reverses for approx. 3 secs.If not used, leave jumpered.

21-26 OPEN control button (NO).

31-32 230V~ transformer primary winding.

33-34 Single-phase power supply 230V, 50-60Hz (33N - 34L).

12)CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD PROGRAMMER (Fig.T)Refer to specific manual.

13) OPPOSITE SLIDING LEAVES (FIG.U)

14) SAFETY DEVICESNOTE: ONLY USE RECEIVING SAFETY DEVICES WITH FREE CHANGEOVER CONTACT.

14 - DEIMOS BT-MA

D81

1343

001

00_0

3

INSTALLATION MANUAL14.1) TESTED DEVICES (FIG.V)

14.2) NON-TESTED DEVICES (FIG.H)

15) CALLING UP MENUS: FIG. 1

15.1) PARAMETERS MENU (PARAM) (PARAMETERS TABLE “A”)

15.2) LOGIC MENU (LOGIC) (LOGIC TABLE “B”)

15.3) RADIO MENU (radio) (RADIO TABLE “C”)- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE

IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).In the event of manual programming, the first transmitter assigns the RECEIVER’S KEY CODE: this code is required to subsequently clone the radio transmitters.The Clonix built-in on-board receiver also has a number of important advanced features: • Cloning of master transmitter (rolling code or fixed code).• Cloning to replace transmitters already entered in receiver.• Transmitter database management.• Receiver community management.To use these advanced features, refer to the universal handheld programmer’s instructions and to the general receiver programming guide.

15.4) LANGUAGE MENU (lingua)Used to set the programmer’s language on the display. 15.5) DEFAULT MENU (default)Restores the controller’s DEFAULT factory settings. Following this reset, you will need to run the AUTOSET function again.

15.6) AUTOSET MENU (AUTOset) FIG. J1Used for automatic setting of motor torque and fast time during opening and closing.Before running the AUTOSET function, adjust slow-down speed (Fig. J).

WARNING! The AUTOSET operation must be performed starting from the closing limit switch position. If you attempt to run the AUTOSET function

in any other position, the following error message will appear: “nsvc” and the operation will not be performed.

WARNING!! The AUTOSET operation must be performed only once you have checked that the leaf is moving accurately (opening/closing) and that the

limit switches are tripping correctly.WARNING: if slow-down speed is edited after the AUTOSET operation, the AUTOSET function will need to be run again.

During this stage, it is important to avoid breaking the photocells’ beams and not to use the START, STOP, PED, CLOS and OPEN commands or the display.

WARNING! While the AUTOSET function is running, the obstacle detection function is not active. Consequently, the installer must monitor the auto-

mated system’s movements and keep people and property out of range of the automated system.When using buffer batteries, the AUTOSET function must be run with the control panel running off mains power.

WARNING! DIAGNOSTICS or: high torque during slow-down in AUTOSET mode. Use a lower slow-down and check movement and smooth operation of leaf.

15.1) TABLE A: PARAMETERS MENU (PARAM)

Parameter min. max. default personal Definition Description

TCA 0 sec. 120 sec. 10 Automatic Closing Time Pause time before automatic closing.

op.t 1% 99% 80 Opening motor torque Sets motor’s operating force during opening at normal speed.

cls.t 1% 99% 80 Closing motor torque Sets motor’s operating force during closing at normal speed.

op.t slow 1% 99% 25 Opening motor torqueduring slow-down Sets motor’s operating force during opening at slowed speed.

cls.t slow 1% 99% 25 Closing motor torque during slow-down Sets motor’s operating force during closing at slowed speed.

norm.op.speed 1 sec. 2 min. 25 Fast Time during Opening Length of normal speed stage during opening.

norm.cls.speed 1 sec. 2 min. 25 Fast Time during Closing Length of normal speed stage during closing.

slow speed 0 3 0 Slow-down speed

Selects slow-down speed.0=no slow-down1=faster slow-down2=medium slow-down3=slower slow-down

Zone 0 128 0 Zone

Serial connection address.Set the Zone number in the range 0 to 127. The zone number allows you to create groups of automated devices, each of which answers to the Zone Master. Each zone can have only one Master. The Master of zone 0 also controls the Masters and Slaves of the other zones.Zone 128: Opposite Sliding Leaves (Fig. U).

15.2) TABLE B: LOGIC MENU (logic)

Logic Default DefinitionCross out

setting used

Description

TCA OFF AutomaticClosing Time

ON Switches automatic closing on.

OFF Switches automatic closing off.

3 step OFF 3 step

ON

Switches to 3-step logic. A start pulse has the following effects:door closed: opensduring opening: stops and switches on TCA (if configured).door open: closesduring closing: stops and opens again

OFF

Switches to 4-step logic. A start pulse has the following effects:door closed: opensduring opening: stops and switches on TCA (if configured)door open: closesduring closing: stops and does not switch on tca (stop)after stop: opens

Ibl open OFF Block PulsesON The start pulse has no effect during opening.

OFF The start pulse has effect during opening or closing.

Photoc.open OFF Photocellsduring opening

ON When beam is broken, operation of the photocell is switched off during opening. During closing, movement is reversed immediately.

OFF When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared.

ENG

LISH

DEIMOS BT-MA - 15

D81

1343

001

00_0

3

INSTALLATION MANUAL

Logic Default DefinitionCross out

setting used

Description

test phot OFF Photocell test

ON Switches photocell testing on

OFFSwitches photocell testing offIf disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not equipped with supplementary test contacts.

test bar OFF Safety edge testing

ON Switches safety edge testing on.

OFFSwitches safety edge testing offIf disabled (OFF), it inhibits the safety edge testing function, enabling connection of devices not equipped with supplementary test contacts.

fault phot ON Fault PhotON The fault input is associated with the photocell test circuit,

up to 4 pairs of tested photocells and one tested safety edge can be connected (Fig. V)

OFF The fault input is associated with the safety edge test circuit,up to 4 tested safety edges and one pair of tested photocells can be connected (Fig. V).

SCA 2Ch OFFGate open light or 2nd radio channel

ON The output between terminals 14-15 is set as Gate open light:in this case, the 2nd radio channel controls pedestrian opening.

OFF The output between terminals 14-15 is set as 2nd radio channel.

preal OFF Pre-alarmON The flashing light comes on approx. 3 seconds before the motors start.

OFF The flashing light comes on at the same time as the motors start.

hold to tun

OFF DeadmanON Deadman mode: operation continues as long as the control key is held down.

(OPEN terminal 21-26, CLOSE terminal 21-22).

OFF Pulse operation, according to 3- or 4-step logic.

start - close

OFF START - CLOSE setting

ON Input between terminals 21-22 works as CLOSE.

OFF Input between terminals 21-22 works as START.

fixed code OFF Fixed codeON Receiver is configured for operation in fixed-code mode.

OFF Receiver is configured for operation in rolling-code mode.

radio prog ON Remote control programming

ON

Enables wireless memorizing of transmitters: 1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in standard mode via the radio menu.2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized.The receiver exits programming mode after 10 secs.: you can use this time to enter other new tran-smitters.This mode does not require access to the control panel.

OFF Disables wireless memorizing of transmitters. Transmitters are memorized only using the relevant Radio menu.

ster OFF Master/slaveON Control panel is set up as the Master unit in a centralized serial connection system.

WARNING: the control panel set as the master must be the first in the series.

OFF Control panel is set up as a Slave unit in a centralized serial connection system.

ice OFF ICEON

The controller automatically adjusts the Amperostop safety trip threshold at each start up. This featu-re is useful when dealing with installations running at low temperatures.WARNING: once this feature has been activated, you will need to perform an autoset opening and closing cycle.

OFF The Amperostop safety trip threshold stays at the same set value.

15.3) TABLE C: RADIO MENU (RADIO)

Description

Add startAdd Start Keyassociates the desired key with the Start command.

add 2chAdd 2ch Keyassociates the desired key with the 2nd radio channel command.

readReadChecks a key of a receiver and, if memorized, returns the position of the remote control in the memory (from 01 to 63) and number of the key (T1-T2-T3 or T4).

erase 64Erase ListWARNING! Erases all memorized remote controls from the receiver’s memory.

Read receiver codeDisplays receiver code required for cloning remote controls.

ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the W LINK remote control is last pressed.

OFF= W LINK programming disabled.

16 - DEIMOS BT-MA

D81

1343

001

00_0

3

OPEN

CLOSE

A

(90°)

FIG. 2

B

C

D

E

OPEN

CLOSE(90°)

MANUALE D’USO: MANOVRA MANUALE/ USER’S MANUAL: MANOVRA MANUALE/ MANUEL D’UTILISATION: MANOVRA MANUALE/ BE-DIENUNGSANLEITUNG: MANOVRA MANUALE/ MANUEL DE USO: MANOVRA MANUALE/ MANUAL PARA DE USO: MANOVRA MANUALE

DEIMOS BT-MA - 37

D81

1343

001

00_0

3

USER’S MANUAL (GB)Thank you for choosing this product. The Firm is confident that its performance will meet your operating needs. This product meets recognized technical standards and complies with safety provisions. We hereby confirm that it is in conformity with the following European directives: 2004/108/EEC, 2006/95/EEC, 98/37/EEC, 99/05/EEC (and later amendments).

1) GENERAL SAFETYWARNING Important safety instructions. Carefully read and comply with the Warnings booklet and Instruction booklet that come with the product as im-proper use can cause injury to people and animals and damage to property. Keep hold of instructions for future reference. This product has been designed and built solely for the purpose indicated herein. Uses not contemplated herein might result in the product being damaged and could be a source of danger- The Firm disclaims all responsibility resulting from improper use or any use

other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.

If installed and used correctly, the automated system will meet the required level of safety. Nonetheless, it is advisable to observe certain rules of behaviour so that accidental problems can be avoided:- Keep adults, children and property out of range of the automated system,

especially while it is operating.- This application is not meant for use by people (including children) with

impaired mental, physical or sensory capacities, or people who do not have suitable knowledge, unless they are supervised or have been instructed by people who are responsible for their safety.

- Children must be supervised to ensure they do not play with the application. Keep remote controls or other control devices out of reach of children in order to avoid the automated system being operated inadvertently.

- The manual release’s activation could result in uncontrolled door movements if there are mechanical faults or loss of balance.

- Do not deliberately hinder the door’s movement and do not attempt to open the door manually unless the actuator has been released with the relevant release knob.

- Check the system frequently, especially cables, springs or supports, to detect any loss of balance and signs of wear or damage.

- When cleaning the outside or performing other maintenance work, always cut off mains power.

- Keep the photocells’ optics and illuminating indicator devices clean. Check that no branches or shrubs interfere with the safety devices (photocells).

- Do not use the automated system if it is in need of repair. In the event of a malfunction, cut off the power, activate the emergency release to allow access and call in qualified technical personnel (professional installer).

- If the automated system requires work of any kind, employ the services of qualified personnel (professional installer).

- Have the automated system checked by qualified personnel once a year.- Anything that is not explicitly provided for in these instructions is not

allowed.- The operator’s proper operation can only be guaranteed if the information given

herein is complied with. The Firm shall not be answerable for damage caused by failure to comply with the installation rules and instructions featured herein.

- Descriptions and illustrations herein are not binding. While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this