SERVER

SERVER

SERVER

SERVER

ServerNe t -Swi tchServe rNe t -Swi tchServe rNe t -Swi tchServe rNe t -Swi tch

InstallationsanleitungInstallationsanleitungInstallationsanleitungInstallationsanleitung

Installation GuideInstallation GuideInstallation GuideInstallation Guide

Page 2: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Sie haben ...

... technische Fragen oder Probleme?

Wenden Sie sich bitte an:• unsere Hotline:

Mo-Fr: 9 - 18 UhrSa: 9 - 14 UhrTel.: ++49 (0) 180 3777 000

• einen unserer Servicepartner• Ihren zuständigen Vertriebspartner• Ihre Verkaufsstelle

Die Adressen Ihrer Servicepartner finden Sie im Garantieheft oder im Service-Adressenheft.

Aktuelle Informationen zu unseren Produkten, Tips, Updates usw. finden Sie im Internet:http://www.fujitsu-siemens.com

Is there ...

... any technical problem or otherquestion you need clarified?

Please contact:• one of our service partners• your sales partner• your sales outlet

The addresses of your service partners are contained in the guarantee booklet or in the serviceaddress booklet.

The latest information on our products, tips, updates, etc., can be found on the Internet under:http://www.fujitsu-siemens.com

Page 3: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,
Page 4: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Dieses Handbuch wurde auf Recycling-Papier gedruckt.This manual has been printed on recycled paper.Ce manuel est imprimé sur du papier recyclé.Este manual ha sido impreso sobre papel reciclado.Questo manuale è stato stampato su carta da riciclaggio.Denna handbok är tryckt på recyclingpapper.Dit handboek werd op recycling-papier gedrukt.

Herausgegeben von/Published byFujitsu Siemens Computers GmbH

Bestell-Nr./Order No.: A26361-K492-Z121-2-7419A26361-K492-Z121-2-7419A26361-K492-Z121-2-7419A26361-K492-Z121-2-7419Printed in the Federal Republic of GermanyAG 1299 12/99

A26361-K492-Z121-1-7419

ServerNet-Switch Installationsanleitung Installation Guide

Page 5: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

ServerNet-Switch

InstallationsanleitungInstallation Guide

Deutsch

English

Ausgabe Dezember 1999December 1999 edition

Page 6: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

ServerNet is a trademark of Tandem Computers Incorporated, protected through use and/orregistration in the United States and many foreign countries. The use of the symbol ®indicates registration in the United States only; registrations may not have been issued yet inother countries.

Alle weiteren genannten Warenzeichen sind Warenzeichen oder eingetragene Warenzeichender jeweiligen Inhaber und werden als geschützt anerkannt.

Copyright � Fujitsu Siemens Computers GmbH 1999.

Alle Rechte vorbehalten, insbesondere (auch auszugsweise) die der Übersetzung, desNachdrucks, der Wiedergabe durch Kopieren oder ähnliche Verfahren.

Zuwiderhandlungen verpflichten zu Schadenersatz.

Alle Rechte vorbehalten, insbesondere für den Fall der Patenterteilung oder GM-Eintragung.

Information contained in this manual is subject to change without notice.

Liefermöglichkeiten und technische Änderungen vorbehalten.

ServerNet is a trademark of Tandem Computers Incorporated, protected through use and/orregistration in the United States and many foreign countries. The use of the symbol ®indicates registration in the United States only; registrations may not have been issued yet inother countries.

All other trademarks referenced are trademarks or registered trademarks of their respectiveowners, whose protected rights are acknowledged.

Copyright � Fujitsu Siemens Computers GmbH 1999

All rights, including rights of translation, reproduction by printing, copying or similar methods,even of parts are reserved.

Offenders will be liable for damages.

All rights, including rights created by patent grant or registration of a utility model or design,are reserved.

Information contained in this manual is subject to change without notice.

Delivery subject to availability. Right of technical modification reserved.

Page 7: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

A26361-K492-Z121-2-7419

ContentsIntroduction .....................................................................................................................................1Notational conventions ......................................................................................................................1

Important notes ...............................................................................................................................2Safety ................................................................................................................................................2

Notes on installing and removing boards ...................................................................................2Manufacturer’s notes .........................................................................................................................3

Disposal and recycling...............................................................................................................3CE certificate .............................................................................................................................3RFI suppression ........................................................................................................................3

FCC Class B Compliance Statement .................................................................................................4Power cord selection .........................................................................................................................5

For the United States and Canada.............................................................................................5Transporting the ServerNet Switch ....................................................................................................7Cleaning the ServerNet Switch..........................................................................................................7

Description of the ServerNet Switch ..............................................................................................8Components ......................................................................................................................................9

Installing the ServerNet Switch ....................................................................................................11Installing the Switch on a surface ....................................................................................................11Installing the Switch in a rack ..........................................................................................................12

Testing the ServerNet Switch .......................................................................................................14Starting the SWIFT program............................................................................................................14Specifying the SPA port type ...........................................................................................................16Running the External Transfer Test .................................................................................................16Troubleshooting and tips .................................................................................................................18Running the Internal Loopback Test ................................................................................................19

Firmware Update ...........................................................................................................................20Carrying out a firmware update........................................................................................................20

Technical data ...............................................................................................................................23

Page 8: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

A26361-K492-Z121-2-7419 English - 1

IntroductionThe ServerNet-Switch combines a maximum of six ServerNet nodes into a network known as aServerNet System Area Network (SAN). A ServerNet node is a server on which a ServerNet PCIAdapter (SPA) is installed (see SPA Installation Guide). The nodes are connected to the ServerNet-Switch via ServerNet cables.

This manual describes the features of the ServerNet-Switch and provides information on how toinstall the ServerNet-Switch on a surface or in a rack, and how to test that it functions correctly.

Notational conventionsThe meanings of the symbols and fonts used in this manual are as follows:

!Pay particular attention to texts marked with this symbol. Failure to observe thiswarning endangers your life, destroys the system, or may lead to loss of data.

iThis symbol indicates additional information and tips.

Ê Texts which follow this symbol describe activities that must be performed in the order shown.

Ë This symbol means that you must enter a blank space at this point.

↵ This symbol means that you must press the Enter key.

Texts in this typeface are screen outputs.

Texts in this bold typeface are the entries you make via the keyboard.

Texts in italics indicate commands or menu item.

"Quotation marks" indicate names of chapters and terms that are being emphasized.

Page 9: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Important notes Safety

2 - English A26361-K492-Z121-2-7419

Important notesIn this chapter you will find information regarding safety which it is essential to take note of whenworking with your device. The manufacturer's notes contain helpful information on your device.

Safety

!Pay attention to the information provided in the manual "Safety and Ergonomics".

• During installation and before operating the device, observe the information on the technicaldata of the ServerNet Switch in the chapter "Technical data".

• Ensure that the local line voltage remains within the range of 100 V to 240 V.

• The ON/OFF switch does not disconnect the ServerNet Switch from the line voltage. Todisconnect the line voltage completely, remove the power plug from the grounded power outlet.

• When cleaning the server, observe the relevant notes in the paragraph "Cleaning theServerNet Switch".

• When connecting and disconnecting cables, observe the relevant notes in the chapter"Installing the ServerNet Switch".

• Keep this Operating Manual together with your device. If you pass on the device to thirdparties, you should also pass on this manual.

Notes on installing and removing boardsBoards with electrostatic sensitive devices (ESD) may be identified by labels.

When you handle boards fitted with ESDs, you must observe the following points under allcircumstances:

• You must always discharge yourself (e.g. by touching a grounded object) before working.

• The equipment and tools you use must be free of static charges.

• Pull out the power plug before inserting or pulling out boards containing ESDs.

• Always hold boards with ESDs by their edges.

• Never touch pins or conductors on boards fitted with ESDs.

Page 10: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Manufacturer’s notes Important notes

A26361-K492-Z121-2-7419 English - 3

Manufacturer’s notes

Disposal and recyclingThis device has been manufactured to the greatest possible degree from materials which can berecycled or disposed of in a manner that is not environmentally damaging. The device is taken backafter use, so that it can be recycled, provided that it is returned in a condition which is the result ofnormal use. Any components not recuperated will be disposed of in an environmentally acceptablemanner.

Do not throw lithium batteries or accumulators into the trashcan. They must be disposed of inaccordance with local regulations concerning special waste.

If you have any questions on disposal, please contact your local office, our service department, or,directly:

Fujitsu Siemens Computers GmbHRecyclingcenterD-33106 Paderborn

Tel.: ++ 49 5251 - 818 010/ Fax: ++ 49 5251 - 818 015

CE certificateThe shipped version of this device complies with the requirements of the EECdirectives 89/336/EEC "Electromagnetic compatibility" and 73/23/EEC "Lowvoltage directive".

RFI suppressionAll other devices connected to or integrated in this product must have RFI suppression inaccordance with EC directive 89/336/EEC. Products meeting these requirements are accompaniedby a certificate issued by the manufacturer and carry the CE symbol.

Page 11: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Important notes FCC Class B Compliance Statement

4 - English A26361-K492-Z121-2-7419

FCC Class B Compliance StatementIf there is an FCC statement on the device, then:The following statement applies to the products covered in this manual, unless otherwise specifiedherein. The statement for other products will appear in the accompanying documentation.

NOTE:

This equipment has been tested and found to comply with the limits for a "Class B" digital device,pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Regulations. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in strict accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipment offand on, the user is encouraged to try to correct the interference by one or more of the followingmeasures:

• Reorient or relocate the receiving antenna.• Increase the separation between equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is

connected.• Consult the dealer or an experienced radio/TV technician for help.

Fujitsu Siemens Computers GmbH is not responsible for any radio or television interference causedby unauthorized modifications of this equipment or the substitution or attachment of connectingcables and equipment other than those specified by Fujitsu Siemens Computers GmbH Thecorrection of interference caused by such unauthorized modification, substitution or attachment willbe the responsibility of the user.

The use of shielded I/O cables is required when connecting this equipment to any and all optionalperipheral or host devices. Failure to do so may violate FCC rules.

Page 12: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Power cord selection Important notes

A26361-K492-Z121-2-7419 English - 5

Power cord selectionThe power cord for this unit has been packed separately and has been selectedaccording to the country of destination. It must be used to prevent electric shock. Use thefollowing guidelines if it is necessary to replace the original cord set.

Figure 1

The female receptacle of the cord setmust meet CEE-22 requirements (seeFigure 1).

For the United States and Canada

Use a UL listed and CSA labeled cord set consisting of a three conductor cord with a maximum

length of 15 feet.

For units which stand on a desk or table, type SVT or SJT cord sets shall be used.

For units which stand on floor, only SJT type cord sets shall be used.

The cord set must be selected according to the current rating for your unit. Please consult Table A

for the selection criteria for power cords used in the United States and Canada.

Page 13: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Important notes Power cord selection

6 - English A26361-K492-Z121-2-7419

Table A:

Cord Type Size of Conductors in Cord Maximum Current Rating of Unit

SJT 18 AWG 10 Amps

16 AWG 12 Amps

14 AWG 12 Amps

SVT 18 AWG 10 Amps

17 AWG 12 Amps

For units set at 115 V:

use a parallel blade, grounding type attachment plug rated 15 A, 125 V (Figure 2).

For units set at 230 V (domestic use):

use a tandem blade, grounding type attachment plug rated 15 A, 250 V

(Figure 3).

Figure 2 Figure 3

For units set at 230 V (outside of the United States and Canada):

use a cord set consisting of a minimum AWG according to Table A and a grounding type attachment

plug rated 15 A, 250 V. The cord set should have the appropriate safety approvals for the country in

which the equipment will be installed and should be marked HAR.

For the United Kingdom

Should the plug on the flexible cord not be of the type for your socket outlets, do not use an adapter

but remove the plug from the cord and discard. Carefully prepare the end of the supply cord and fit a

suitable plug.

Page 14: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Transporting the ServerNet Switch Important notes

A26361-K492-Z121-2-7419 English - 7

WARNING

THIS APPLIANCE MUST BE EARTHED

IMPORTANT

The wires in this mains lead are colored in accordance with the following code:

Green and Yellow: Earth

Blue: Neutral

Brown: Live

As the colors of the wires in the mains lead of this appliance may not correspond with the colored

markings identifying the terminals in your plug, proceed as follows:

• The wire which is colored Green and Yellow must be connected to the terminal in the plugwhich is marked with the letter E or by the earth symbol or colored Green or Green and Yellow.

• The wire which is colored Blue must be connected to the terminal which is marked with theletter N or colored Black.

• The wire which is colored Brown must be connected to the terminal which is marked with theletter L or colored Red.

Transporting the ServerNet Switch

!Transport the device separately, and in its original packaging or in a packagingwhich protects it from knocks and jolts, to the new site. Do not unpack it until alltransport maneuvers are completed.

Cleaning the ServerNet Switch

!Turn off all power and equipment switches and pull the power plug out of thegrounded power outlets.

Do not clean any interior parts yourself, leave this job to a service technician.

Do not use any cleaning agents that contain abrasives or may corrode plastic.

Ensure that no liquid enters the system.

Ensure that the ventilation areas are free.

Wipe the casing of the device with a dry cloth. If particularly dirty, use a cloth which has beenmoistened in mild domestic detergent and then carefully wrung out.

Page 15: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Description of the ServerNet Switch Cleaning the ServerNet Switch

8 - English A26361-K492-Z121-2-7419

Description of the ServerNet SwitchDer ServerNet-Switch verbindet drei oder mehr ServerNet-Knoten (bis zu 6 Knoten). Either the Xport (X network) or the Y port (Y network) is used at the ServerNet PCI Adapter (SPA) for thispurpose.An SPA-X link connects several nodes via their X port, an SPA-Y link connects nodes via their Yport.A ServerNet Switch may use only one SPA link type. High availability of the configuration can beachieved by using an X network and a Y network. ServerNet nodes are identified by means of theirnode ID.

Using two ServerNet cables ensures that you have an error-tolerant configuration, which will help toprevent cable faults.If, for example, the X cable fails, control switches to the Y network, automatically and transparentlyfor the applications. You must plan a separate ServerNet switch for the Y network.

In the actual ServerNet Switch version the SPA link is predefined as an X network; the node ID isset accordingly. The network is switched over using the X-Y switch in the ServerNet Switch. Whichnetwork is set is indicated by the LED on the front of the ServerNet Switch. The node ID depends onthe port used and is permanently set in the ServerNet Switch firmware (see also SWIFT testprogram).

Page 16: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Components Description of the ServerNet Switch

A26361-K492-Z121-2-7419 English - 9

ComponentsThe diagram below shows the arrangement of the individual components in the ServerNet Switch(the numbers of the ports are located on the rear of the upper part of the housing).

Connector

Daughterboard

PowerSupply

RouterASIC

Cooling Unit

Display Board

Motherboard

X-Y Switch

Connector Connector Connector Connector Connector Power InletPort 5 Port 4 Port 3 Port 2 Port 1 Port 0

MaintenanceMicrocontroller

Ribbon Cable

Daughterboard

Daughterboard

Daughterboard

Daughterboard

Daughterboard

Page 17: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Description of the ServerNet Switch Components

10 - English A26361-K492-Z121-2-7419

The diagram below shows the front of the ServerNet Switch.

X

1 2 3 4 5

Y

1 = Network indicator2 = ServerNet Switch ID3 = Self-test/error indicator (yellow)

4 = Power-on indicator (green)5 = Netzschalter

• The system board includes:− a micro-controller which monitors the ServerNet Switch and downloads firmware, if

necessary− a router ASIC in which the switching matrix for ServerNet packages is implemented− an X-Y switch for selecting the X or Y network.

• Each daughter board contains a ServerNet transceiver ASIC and the connection for theServerNet cable.

• The indicators on the front of the unit refer to the following components - from left to right:− two green LEDs which indicate whether the ServerNet Switch is set to an SPA-X or to an

SPA-Y network.− two numeric indicators with seven segments for use in a future version of the ServerNet

Switch.− a yellow LED which indicates that the ServerNet Switch is running a self-test or that a fault

has occurred.− a green LED indicating power-on.

Page 18: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Installing the Switch on a surface Installing the ServerNet Switch

A26361-K492-Z121-2-7419 English - 11

Installing the ServerNet SwitchYou can install the ServerNet Switch on a surface or in a rack.

Installing the Switch on a surfaceProceed as follows to install the ServerNet Switch as a surface-mounted device:

1. Ensure that the four rubber feet on the underside are fitted correctly and place the ServerNetSwitch on a hard, flat surface (not on a carpet) to ensure that air can circulate freely.

2. Plug the power cable into a grounded outlet and into the power supply connection of theServerNet Switch.

3. Switch the ServerNet Switch on at its front panel. The green LED lights when the ServerNetSwitch is switched on. The yellow LED also lights briefly. The self-test was successful. Wenndie gelbe Anzeige weiterleuchtet, schalten Sie den ServerNet-Switch am Netzschalter aus undwieder ein. If the yellow LED still lights, the ServerNet Switch is faulty and must be replaced.

4. Connect the ServerNet cables to the ServerNet Switch ports and to the SPA ports of the nodes(SPA-X or SPA-Y ports, depending on the network used). Screw the cables tight at theServerNet PCI Adapter and at the ServerNet Switch.

!When connecting the cables, ensure that you do not bend or break off theconnecting pins.

Page 19: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Installing the ServerNet Switch Installing the Switch in a rack

12 - English A26361-K492-Z121-2-7419

Installing the Switch in a rackBefore installing the ServerNet Switch in a rack, study the following diagram and then proceed asdescribed below:

Side view

Flange

Rack - mounting bracket

Switch

Power cord Cable-support-bracket

Front of Switch(top view)

1. Fastening the rack bracket

You need a rack bracket and a cable support for rack installation.

Ê Position the bracket on the side of the ServerNet Switch so that the bracket flange pointsoutwards.

Ê Align the bracket flange on the support area on the front of the ServerNet Switch. Fasten thebracket with two screws each.

2. Fastening the cable support

Ê Position the flanges of the cable support between the rack brackets at the bottom end of thebrackets. The two drilled holes separate from the other pairs of holes must be situated oppositethe power connection; the other six pairs of holes must be opposite the ServerNet ports 0-5.Secure the cable support on each side using two screws.

Page 20: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Installing the Switch in a rack Installing the ServerNet Switch

A26361-K492-Z121-2-7419 English - 13

3. Mounting the ServerNet Switch in the rack

iAfter installing the ServerNet Switch it may be difficult to attach the cables at therear. In this case, do not install the ServerNet Switch in the rack until you havecarried out steps 4-6.

If there is not enough space in the rack, remove the rubber feet from the undersideof the ServerNet Switch.

If necessary, you can remove the front panel of the ServerNet Switch when youare performing installation.

Ê Ensure that the screws supplied for the assembly rails at the rack fit.

Ê Insert the prepared ServerNet Switch into the front of the rack and secure it at each side usingtwo screws.

4. Connecting the power cable

Plug the power cable into a grounded outlet and into the power supply connection of the ServerNetSwitch.

5. Switching on power

Switch the ServerNet Switch on at its front panel. The green LED lights when the ServerNet Switchis switched on. The yellow LED also lights briefly. The self-test was successful. If the yellow LEDcontinues to light, switch the ServerNet Switch off at the main switch and then back on again. If theyellow LED still lights, the ServerNet Switch is faulty and must be replaced.

6. Connecting cables

Ê Connect the ServerNet cables to the ServerNet Switch ports and to the SPA ports of the endnodes (SPA-X or SPA-Y ports, depending on the network used). Screw the cables tight at theServerNet PCI Adapter and at the ServerNet Switch.

iWhen connecting the cables, make sure that the connection pins are not bent orbroken off.

Ê Hold the power cable so that it is located between the two outer holes in the cable support.Attach the power cable to the cable support using a cable tie.

Ê Attach the ServerNet cables to the cable support in the same way.

Page 21: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Testing the ServerNet Switch Starting the SWIFT program

14 - English A26361-K492-Z121-2-7419

Testing the ServerNet SwitchYou should run the "Switch Functional Test" (SWIFT) program at all nodes connected via theServerNet Switch. The program is shipped on a 3.5" diskette configured as an MS DOS bootdiskette. The SWIFT program comprises two different tests:

• The external transfer test checks whether the local ServerNet PCI Adapter (SPA) iscommunicating with the ServerNet Switch and with the remote end nodes.

• The internal loopback test checks whether the local SPA is functioning correctly; links to otherend nodes are not tested.

The SWIFT program described here works with the following products:

• ServerNet-Switch 1, S26 361-K492-V1 (type plate on the back)

• SPA, Version 1, S26 361-D1045-V1 (type plate on the board)

• SPA, Version 3, S26 361-D1118-V1 (type plate on the board)

Starting the SWIFT programStart the SWIFT program on each node with which the ServerNet Switch is connected:

Ê Insert the SWIFT diskette into the appropriate drive and reboot the server.

Ê Enter the following when the DOS prompt appears:

SWIFTxx localID [remoteID1---remoteIDn]

xxstands for the version of the SWIFT program (decimal point is omitted) as indicated in the filerelnot.txt on the shipped diskette

Example: enter SWIFT03 if you are using SWIFT Version 0.3.

localIDstands for the ServerNet node ID of the local node.

remoteID1---remoteIDnstands for the individual ServerNet node IDs of the remote nodes. The individual node IDsmust be separated by blanks. If you do not specify any node IDs for remote nodes, the externaltransfer test includes five nodes by default. If you specify "0", the external transfer test checksonly communication between the local node and the ServerNet-Switch.

You can request help information on the command syntax at any time by entering the followingafter the DOS prompt:SWIFTxx or SWIFTxx HELP.

Page 22: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Starting the SWIFT program Testing the ServerNet Switch

A26361-K492-Z121-2-7419 English - 15

The ServerNet default node IDs are as follows in the current release of the ServerNet Switch:

Port ServerNet Node ID

0 F0040

1 F0080

2 F00C0

3 F0100

4 F0140

5 F0180

Ê When the copyright and licensing information appears on the screen, press [ENTER]ENTER]ENTER]ENTER].Press any key to continue.

The SWIFT main menu appears on the screen:

Ê Repeat the above steps at each node.

MAIN MENU: Port = X

---------------SETUP-------------

X = Port X select

Y = Port Y select

---------------TESTS--------------

I = Internal loopback test

E = External transfers (write/read/compare to remote nodes)

Q = Quit. Exit SWIFT.

Menu selection?:

Page 23: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Testing the ServerNet Switch Specifying the SPA port type

16 - English A26361-K492-Z121-2-7419

Specifying the SPA port typeA ServerNet Switch belongs either to an X network or to a Y network. The X/Y LED at the front ofthe ServerNet Switch indicates to which network the switch is set. All nodes of the networkbelonging to a specific ServerNet Switch must be connected via the same SPA port. The SWIFTprogram is predefined for the X network (port X).

If necessary, change the predefined SWIFT setting for each node by entering X or Y in the mainmenu in response to the promptMenu selection?:.

Running the External Transfer TestYou must run the external transfer test on each individual node. To do this, first enter E in theSWIFT main menu.A graphical display of the ServerNet Switch configuration appears on screen; the local node (thenode on which the ServerNet Switch is being tested) is shown on the left. On the local link SWIFTissues the message LINK ALIVE and screen output stops at this point. If LINK DEAD is displayed,please note down all messages which appear on the screen and refer to the chapter“Troubleshooting and tips”.

If the message LINK ALIVE appears on all nodes, strike any key (on each individual node but inany order) to start the external transfer test. The screen now displays documentation on all transfersand errors for each node.

Page 24: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Running the External Transfer Test Testing the ServerNet Switch

A26361-K492-Z121-2-7419 English - 17

If the error count is not zero for a node, this is shown in red to indicate that the node is notcommunicating correctly. Note down all the messages that appear on the screen and refer to thechapter “Troubleshooting and tips”.

If you want to end the test, strike any key to return to the main menu. Enter Q in the main menu toquit Swiftxx.

SWITCH

ID = xxxxxx

Xfers = xxx

Errors = xxx

ID = xxxxxx

Xfers = xxx

Errors = xxx

ID = xxxxxx

Xfers = xxx

Errors = xxx

ID = xxxxxx

Xfers = xxx

Errors = xxx

ID = xxxxxx

Xfers = xxx

Errors = xxx

ID = xxxxxx

Xfers = xxx

Errors = xxxALIVE

SWIFT03

Date: xx/xx

Time: xx:xx:xx

Transfer Length: 4096

Transfer Mode: EXTERNAL WITH DATA COMPARE

Data Pattern: INCREMENT

Node Select: RANDOM

Loop on Error: ON

Message:

Strike any key to exit.

LINK

Page 25: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Testing the ServerNet Switch Troubleshooting and tips

18 - English A26361-K492-Z121-2-7419

Troubleshooting and tipsIf you receive the message LINK DEAD when running the SWIFT program, check the following:

• The ServerNet Switch is switched on.• The ServerNet cable is correctly connected both at the node and at the ServerNet Switch.• The SPA is correctly installed on the node, the card is firmly inserted in the PCI slot (see also

Technical Manual for ServerNet PCI Adapter, SPAF Test).• The SPA port used (X or Y) corresponds to the network preset in the ServerNet Switch and to

the network selected in the SWIFT program (indicated in the top part of the SWIFT mainmenu).

• The settings of the ServerNet node IDs are correct.• You have specified the correct ServerNet ID when invoking SWIFT.• The ServerNet cable is not faulty - test by using an intact ServerNet cable.

If link is alive is displayed but running the external transfer test produces a non-zero errorcount, you should then check the following:

• The SPA is functioning correctly. Check this by running an internal loopback test (see chapter"Running the Internal Loopback Test”).

• The node is communicating with the ServerNet Switch. Check this by running an externaltransfer test for this node (i.e. enter the following after the DOS prompt: SWIFTxx localID0).

iErrors occurring on a specific node may be reported by other nodes included in thetest run.Once you have solved the problem, you should reset the error counter to 0. To dothis, strike any key to terminate the test run and enter E in the main menu to restartthe external transfer test.

Page 26: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Running the Internal Loopback Test Testing the ServerNet Switch

A26361-K492-Z121-2-7419 English - 19

Running the Internal Loopback TestTo run an internal loopback test, enter I in the SWIFT main menu and note the screen output:

If there are no errors, the following is displayed for the local node: LINK ALIVE and Errors = 0. Ifhowever LINK DEAD or Errors > 0 is displayed, the SPA is faulty and you must replace it. In theinternal loopback test the message LINK DEAD/ALIVE does not refer to the external cable. Oncethe internal loopback test has run satisfactorily for about two minutes, strike any key to return to themain menu. In the main menu enter Q to quit the test.

SWITCH

ID = xxxxxx

Xfers = xxx

Errors = xxx

ID = xxxxxx

Xfers = 0

Errors = 0

ID = xxxxxx

Xfers = 0

Errors = 0

ID = xxxxxx

Xfers = 0

Errors = 0

ID = xxxxxx

Xfers = 0

Errors = 0

ID = xxxxxx

Xfers = 0

Errors = 0

SWIFT03

Date: xx/xx

Time: xx:xx:xx

Transfer Length: 4096

Transfer Mode: INTERNAL LOOPBACK

Data Pattern: INCREMENT

Node Select:

Loop on Error: ON

Message:

Strike any key to exit.

ALIVE

LINK

Page 27: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Firmware Update Carrying out a firmware update

20 - English A26361-K492-Z121-2-7419

Firmware UpdateThe data for the ServerNet Switch firmware update and the DOS program for carrying out thefirmware update are shipped on a 3.5" diskette and can be ordered at the customer service. DieDateien müssen auf eine bootfähige Diskette kopiert werden. The update can be performed on anyserver which can be booted from diskette and which is connected to the ServerNet Switch.

If the ServerNet System Area Network (SAN) is operating both an SPA-X and an SPA-Y network,the firmware on both ServerNet Switches must be updated. The update program must then be runfor each ServerNet Switch. In the following the ServerNet Switch for the SPA-X network is referredto as the X ServerNet Switch, the switch for the SPA-Y network as the Y ServerNet Switch.

iIf firmware updating fails and, as a result, the ServerNet Switch no longer functionscorrectly, you should replace the ServerNet Switch. In this instance, please contactour service. It is not possible to use an old firmware update for purposes ofrecovery in this particular case.

Carrying out a firmware updateFirmware updating comprises the following steps:

Ê Select a node in the ServerNet cluster from which you want to carry out the firmware update.

You may select any node which has a ServerNet link to the ServerNet Switch to beupdated.

• To carry out the update for an X ServerNet-Switch, the node must be connected to theServerNet-Switch via the X port.

• To carry out the update for a Y ServerNet Switch, the node must be connected to theServerNet Switch via the Y port.

If a ServerNet Switch has a free port, a non-networked DOS system or a server not yet included inSAN management can be connected to the ServerNet Switch in order to perform the update.However, in both cases the system must be equipped with an SPA.

If an X and a Y network are operated in the SAN, it is advisable to connect the server to anX ServerNet Switch and to a Y ServerNet Switch.

In addition, the server must be configured so that it can boot from diskette.

Page 28: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Carrying out a firmware update Firmware Update

A26361-K492-Z121-2-7419 English - 21

The following graphic shows the link to an X ServerNet Switch and to a Y ServerNet Switch.

XServerNet Switch YServerNet Switch

XPort YPort

SPA

Server

Ê Shut down the selected node normally, i.e. exit all applications and then the operating system.

− If the node was part of the SAN, this operation affects the other nodes of the SAN as theycan no longer communicate with this node.

− If the node was added to the SAN for purposes of the firmware update and was notpreviously part of the SAN, the shutdown operation has no effect on the other nodes in theSAN.

Ê Switch off the node.

Ê Insert the diskette with the firmware update in the drive and switch the node back on again.

− The node boots from diskette. You are shown the MS-DOS prompt once the bootoperation has completed successfully.

− The firmware update cannot be carried out if the node does not boot from diskette.

Ê View the contents of the diskette by entering the dir command. Note that:

− the name of the firmware update program is FWUPvv, where vv indicates the version.− data is contained in the file LITv.hex, where v indicates the version.

This information is also included in the Release Note.

Ê Enter the name of the firmware update program, e.g. FWUP14

The licensing and copyright information is displayed.

Ê When prompted, specify whether an X or a Y network is to be updated.

− Enter X to update an X network.

− Enter Y to update a Y network.

The update program is terminated immediately if the SPA port used for the node does notmatch the setting at the ServerNet Switch (X port with an X ServerNet Switch, Y port with aY ServerNet Switch).

The update program tests the link between the SPA and the ServerNet Switch.

• LINK test O.K. is displayed if the link is functioning correctly.• Error: <error message> is displayed if the link is not functioning correctly. The update

program is terminated immediately. If this happens, check the cable connection between thenode and the ServerNet Switch and restart the update program.

Page 29: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Firmware Update Carrying out a firmware update

22 - English A26361-K492-Z121-2-7419

Ê When prompted, enter the name of the file containing the data, e.g. LIT8.hex

The update program updates the firmware of the ServerNet Switch and tests the link once again.This is indicated by the following messages:

Sending data (/)

Waiting for memory to update ...

Waiting for switch reset

Testing the ServerNet link.

Link test O.K.

The message Firmware update successful is displayed to indicate successful completion ofthe update operation.

Ê Once you have performed updating for an X ServerNet-Switch, repeat the same steps for the YServerNet-Switch, if available. To do this, start the firmware update program on the currentnode and select the Y network or find a suitable new node which is connected with aY ServerNet Switch.

Ê Once the firmware update has been correctly performed for both ServerNet Switches, removethe diskette from the drive and restart the node. If the node was connected to theServerNet Switch solely for purposes of the firmware update, do not forget to remove theconnecting cable to the ServerNet Switch.

Page 30: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Carrying out a firmware update Technical data

A26361-K492-Z121-2-7419 English - 23

Technical dataThe dimensions of the ServerNet Switch are as follows:

Dimensions

Width:Depth:Height:

428 mm346,5 mm41,5 mm

Environmental conditions

Environment class 3K2Environment class 2K2

DIN IEC 721 part 3-3DIN IEC 721 part 3-2

Temperature:• Operating (3K2)• Transport (2K2)

15 °C .... 35 °C-25 °C .... 60 °C

Condensation in operating must be avoided.

Electrical data

Power consumption 50 - 60 W

Supply voltage: 5,0 V DC

Page 31: ServerNet-Switch - Fujitsumanuals.ts.fujitsu.com/file/3464/servernet-switch-ag-en.pdf · Este manual ha sido impreso sobre papel reciclado. ... All rights, including rights of translation,

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009