Sprecher Schuh CA7_Contactors.pdf

download Sprecher Schuh CA7_Contactors.pdf

of 19

Transcript of Sprecher Schuh CA7_Contactors.pdf

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    1/19A30

    Contactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Series CA7Contactors

    Rugged, space savingand modularSprecher + Schuhsnewest contactor forapplications up to75HP @ 460V

    Over 100 years of design experiencehas produced Sprecher + Schuhsseventh generation contactor line.Te CA7 represents the most modernand flexible power contactor availabletoday, meeting the highest industrialapplication requirements.

    Big performance in asmall packageA wide selection of eleven contactorsin four frame sizes covers the entireCA7 horsepower range (up to 75HP @460/575V). Six of the contactors areonly 45mm wide, an extremely smallfootprint for such rugged perfor-mance. A number of design featuresaccount for this efficiency, includinghigh contact pressure and bounce-free contacts, allowing the devices tohandle the high starting currents typi-cal of modern motors.

    Type 1 and Type 2Coordination

    Whether youre designing motor cir-cuits for use in North America, Europeor any other part of the world, all CA7contactors have been designed and

    tested with respect to Type 1 and Type2 short circuit coordination. Find outmore in the CA7 Technical Informa-tion section in this chapter.

    45mm(1 3/4)

    9A12A16A23A

    45mm(1 3/4)

    30A37A

    54mm(2 1/8)

    43A

    72mm(2 13/16)

    60A72A85A97A

    Advanced safety andreliability featuresTe entire CA7 line features me-chanically linked contacts, sometimesreferred to as positively guidedcontacts or force guided contacts.If a main power pole welds, adequate

    clearances exist (0.3mm) to en-sure that the auxiliary contacts donot change state when coil power isremoved and the device tries to open.Tis is a requirement in safety circuitsper IEC 60947-5-1.

    Reliability is further assured by cross-stamped auxiliary contacts, whichprovide multi-point reliability in lowcurrent, low voltage applications.

    Advantages of ElectronicDC CoilCA7-9E through CA7-43E areprovided with DC coils that dramati-cally decrease wattage consumptionduring pull-in. Tis allows the use ofsmaller power supplies. Te electronicDC coil design brings the height ofthe contactor back down to the samesize as the AC version. Select CA7contactors are also available with atwo-winding DC coil that reducesthe size of the contactor as well as thehold-in values.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    2/19A31visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Special use contactors forspecialized applicationsTe CA7 line has been expanded to in-clude a number of contactors designedand labeled for specific industrialapplications. In all cases, these devicesare UL and CSA approved for thesespecialized uses.

    Lighting contactors

    Te CAL7 contactor can be usedto control a wide variety of lightingloads. Tese contactors are well suitedto handle the high inrush currentstypical of this application as well asother non-motor (resistive) loads. Bothmechanically held and electrically heldmodels are available for lighting loadapplications up to 20A, 30A and 60A.

    Modular accessories arecommon to all devicesAll accessories are interchangeableamong all CA7 contactors and CS7control relays. Tis minimizes inven-tory requirements and maximizes flex-ibility. op and side mount auxiliarycontacts are available depending onyour application. A mechanical inter-lock with two built-in NC auxiliariesalso provides electrical interlocking ifdesired. Pneumatic and electronic tim-ers, surge suppressors and electronicinterface modules provide solutions foreven the most complex applications.

    Reversible coil providestotal flexibilityWhen shipped, both coil connectionsare normally located at the top of thecontactor in preparation for mountingan overload relay at the bottom. Formulti-starter panels, however, the coilcan be reversed, which provides spaceto close-couple a K7 Motor CircuitController on the top of the contactor.CA7 contactors can either be orderedwith the coil reversed or may be easilyreversed in the field.

    Dual power terminalsspeed wiringCA7-30 through 97 contactors aredesigned with two power terminals for

    all three poles. Tis simplifies powerwiring of interconnected contactors inreversing, reduced voltage and two-speed applications. Preformed powerwiring connectors are also available forvirtually instantaneous wiring in theselabor intensive applications. Simplifiedwiring means less labor and less cost.

    Top mounted

    coil

    Two power terminalson each pole

    Dual power terminals assure hassle-free wirin

    in complex control schemes

    Reversible coils are standard on all

    CA7 contactors

    Bottom

    mounted coil

    Sprecher + Schuhs expanded CA7 line includes

    contactors designed and labeled for specific

    industrial applications

    CAL7 Lighting

    Contactor

    CAN7 NEMA

    labeled contactor

    CNX Special Purpose

    Contactor

    NEMA Labeled ContactorsCAN7 contactors are UL Listed andrated in accordance with the require-ments of NEMA standards publicatioICS-2. Tese contactors are NEMAcompliant and are labeled accordingly

    Special purpose contactorsCNX contactors are standard CA7contactors that have been tested, ap-

    proved and labeled by UL for heat-ing ventilation and air conditioning(HVAC) applications.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    3/19A32

    Contactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    Contactors - AC Coil

    Three Pole - Series CA7

    Non-Reversing, Three Pole Contactors With AC Coil, Series CA7(Open type only)

    Coil Codes

    AC1 Resistive Ratings and UL/CSA Continuous Current Ratings may be increasedby the use of Lug Kits or Paralleling Links. See CA7 Accessories section for ap-plicable information.

    Other voltages available, see page A56. Non-standard coil voltages not listed heremust be ordered and installed separately as renewal parts.

    Coil Terminal PositionAll CA7 contactors are stocked and delivered with the coil

    terminals located on the line side (top) of the contactor. Thisis the typical configuration when using the contactor with anoverload relay. When the contactor is used with the KT7 Motor

    Circuit Controller, the coil must be reversed, so that the coilterminals are located at the load side (bottom) of the contactor.

    CA7 coils can easily be reversed in the field, however, they arealso available for order with the coils reversed from the factory.

    Contact your Sprecher+Schuh representative for more infor-mation about ordering CA7 contactors with reversed coils.

    All CA7 contactors come with

    reversible coils.

    CA7-9-10 contactor

    CA7-43-00 contactor

    CA7-60-00 contactor

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4)Auxiliary

    Contacts per

    Contactor

    Open Type

    CatalogNumber Price

    kW(50 Hz) UL/CSA HP(60 Hz)

    230V400V /415V 500V 690V

    1 3

    AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/21 0 CA7-9-10-

    1200 1 CA7-9-01-

    12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 101 0 CA7-12-10-

    1550 1 CA7-12-01-

    16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 151 0 CA7-16-10-

    1740 1 CA7-16-01-

    23 32 7.5 11 13 10 2 3 5 7-1/2 15 151 0 CA7-23-10-

    1930 1 CA7-23-01-

    30 65 10 15 15 15 2 5 7-1/2 10 20 25

    0 0 CA7-30-00- 222

    1 0 CA7-30-10- 244

    0 1 CA7-30-01- 244

    37 65 11 18.5/20

    20 18.5 3 5 10 10 25 30

    0 0 CA7-37-00- 266

    1 0 CA7-37-10- 288

    0 1 CA7-37-01- 288

    43 85 13 22 25 22 3 7-1/2 10 15 30 30

    0 0 CA7-43-00- 286

    1 0 CA7-43-10- 308

    0 1 CA7-43-01- 308

    60 100 18.5 32 37 32 5 10 15 20 40 50

    0 0 CA7-60-00- 350

    1 0 CA7-60-10- 372

    0 1 CA7-60-01- 372

    72 100 22 40 45 40 5 15 20 25 50 60

    0 0 CA7-72-00- 403

    1 0 CA7-72-10- 425

    0 1 CA7-72-01- 425

    85 100 25 45 55 45 7-1/2 15 25 30 60 60

    0 0 CA7-85-00- 460

    1 0 CA7-85-10- 482

    0 1 CA7-85-01- 482

    97 130 30 55 55 55 10 20 30 30 75 75 0 0CA7-97-00- 577

    1 0 CA7-97-10- 599

    0 1 CA7-97-01- 599

    AC

    Coil Code

    Voltage Range

    50 Hz 60 Hz

    24Z 24V 24V

    120 110V 120V

    208 ~ 208V

    220W 200V-220V 208V-240V

    240 220V 240V

    277 240V 277V

    380 380V-400V 440V

    480 440V 480V

    600 550v 600V

    Ordering InstructionsSpecify Catalog Number

    Replace () with Coil CodeSee Coil Codeson this page.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    4/19A33visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    Contactors - AC Co

    Four Pole - Series CA

    Non-Reversing, Four Pole Contactors With AC Coil, Series CA7(Open type only)

    Other voltages available, see page A56. Non-standard coil voltages not listed hermust be ordered and installed separately as renewal parts.

    Coil Codes

    CA7-23-M22-120 contactor

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4)Contact

    Configuration,Main Pole

    Open Type

    CatalogNumber Price

    kW(50 Hz) UL/CSA HP(60 Hz)

    230V400V415V 500V 690V

    1 3

    AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2432

    012

    CA7-9-M40-

    CA7-9-M31-

    CA7-9-M22-

    120

    132

    132

    12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10432

    012

    CA7-12-M40-

    CA7-12-M31-

    CA7-12-M22-

    157

    167

    167

    16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15432

    012

    CA7-16-M40-

    CA7-16-M31-

    CA7-16-M22-

    176

    186

    186

    23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

    4

    32

    0

    12

    CA7-23-M40-

    CA7-23-M31-CA7-23-M22-

    194

    206206

    37 75 11 18.5 20 18.5 3 5 10 10 25 30 4 0 CA7-40-M40- 385

    37 75 11 18.5/20 18.5 7.5 3 5 10 10 25 15 2 2 CA7-40-M22- 385

    85 130 25 45 55 45 7-1/2 15 25 30 60 50 4 0 CA7-90-M40- 657

    85 130 25 45 55 18.5 7-1/2 15 25 30 50 20 2 2 CA7-90-M22- 657

    AC

    Coil Code

    Voltage Range

    50 Hz 60 Hz

    24Z 24V 24V

    120 110V 120V

    208 ~ 208V

    220W 200V-220V 208V-240V

    240 220V 240V

    277 240V 277V

    380 380V-400V 440V

    480 440V 480V600 550V 600V

    Ordering InstructionsSpecify Catalog Number

    Replace () with Coil CodeSee Coil Codeson this page.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    5/19

    A34

    Co

    ntactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    CA7-37E-00-24E contactor

    Contactors - Low Consumption Electronic DC Coil

    Three Pole - Series CA7

    Non-Reversing, Three Pole Contactors With Electronic DC Coil, Series CA7(Open type only)

    AC1 Resistive Ratings and UL/CSA Continuous Current Ratings may be increased by the use of

    Lug Kits or Paralleling Links. See CA7 Accessories section for applicable information.

    CA7-9E43E with electronic coils are not interchangeable with non-electronic DC or AC coils.

    See page A47 for limitations on adding auxiliaries to Electronic DC Coil contacts.

    Voltages of 48V DC and greater are supplied with backpack module standard. See page A85.

    Not applicable with Electronic Timer accessories (CRZ_7).

    Description

    Low Consumption Electronic DC coils have extremely low

    inrush which allows the use of smaller power supplies.

    CA7-9E43E has internal surge suppression. See page A68 for

    more information.

    This new design results in:

    Lighter, lower depth

    More energy efcient contactors

    Easier wiring Uniform panel appearance.

    Applications

    Direct control from PLC:

    The low power consumption contactor designed to control

    motors and other loads is especially aligned to the specic

    requirement of electronic control circuits. The low power

    consumption of 1.7 allows direct control through PLCs

    without the need for interposing relays. Power dissipation is

    greatly reduced limiting the heat effect in control panels.

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4)Auxiliary

    Contacts perContactor

    Open Type

    CatalogNumber Price

    kW(50 Hz) UL/CSA HP (60 Hz)

    230V

    400V/

    415V 500V 690V

    1 3

    AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/21

    0

    0

    1

    CA7-9E-10-

    CA7-9E-01-197

    12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 101

    0

    0

    1

    CA7-12E-10-

    CA7-12E-01-242

    16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 151

    0

    0

    1

    CA7-16E-10-

    CA7-16E-01-267

    23 32 7.5 11 13 10 2 3 5 7-1/2 15 151

    0

    0

    1

    CA7-23E-10-

    CA7-23E-01-292

    30 65 10 15 15 15 2 5 7-1/2 10 20 25

    0

    1

    0

    0

    0

    1

    CA7-30E-00-

    CA7-30E-10-

    CA7-30E-01-

    332

    354

    354

    37 65 11 18.5/20

    20 18.5 3 5 10 10 25 30

    0

    1

    0

    0

    0

    1

    CA7-37E-00-

    CA7-37E-10-

    CA7-37E-01-

    392

    414414

    43 85 13 22 25 22 3 7-1/2 10 15 30 30

    0

    1

    0

    0

    0

    1

    CA7-43E-00-

    CA7-43E-10-

    CA7-43E-01-

    455

    475

    475

    Coil Terminal PositionAll CA7 contactors are stocked and delivered with the coil terminals

    located on the line side (top) of the contactor. This is the typical

    conguration when using the contactor with an overload relay. When

    the contactor is used with the KT7 Motor Circuit Controller, the coil

    must be reversed, so that the coil terminals are located at the load

    side (bottom) of the contactor. CA7 coils can easily be reversed in the

    eld, however, they are also available for order with the coils reversed

    from the factory. Contact your Sprecher+Schuh representative for more

    information about ordering CA7 contactors with reversed coils.

    All CA7 contactors come withreversible coils.(48V DC shown)

    Coil Codes

    DC Coil Codes Voltage

    12E 12V

    24E 24V

    48E 48-72V

    110E 110-125V

    220E 220-250V

    CA7-23E-10-24E contactor

    CA7-16E-10-110E contactor

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    6/19

    A35visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    Contactors - Low Consumption Electronic DC Co

    Four Pole - Series CA

    Non-Reversing, Four Pole Contactors With Electronic DC Coil, Series CA7(Open type only)

    CA7-23E-M22-24E contactor

    Ie

    [A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4)Contact

    Configuration,

    Main Pole

    Open Type

    Catalog Number Price

    kW (50 Hz) UL/CSA HP(60 Hz)

    230V

    400V

    415V 500V 690V

    1 3

    AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2

    4

    3

    2

    0

    1

    2

    CA7-9E-M40-

    CA7-9E-M31-

    CA7-9E-M22-

    198

    210

    210

    12 32 1 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10

    4

    3

    2

    0

    1

    2

    CA7-12E-M40-

    CA7-12E-M31-

    CA7-12E-M22-

    240

    252

    252

    16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15

    4

    3

    2

    0

    1

    2

    CA7-16E-M40-

    CA7-16E-M31-

    CA7-16E-M22-

    264

    277

    277

    23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

    4

    3

    2

    0

    1

    2

    CA7-23E-M40-

    CA7-23E-M31-

    CA7-23E-M22-

    290

    302

    302

    37 75 11 18.5 20 18.5 3 5 10 10 25 30 4 0 CA7-40E-M40- 520

    37 75 11 18.5/20 18.5 7.5 3 5 10 10 25 15 2 2 CA7-40E-M22- 535

    CA7-9E43E with electronic coils are not interchangeable with non-electronic DC or AC coils

    See pages A47 for limitations on adding auxiliaries to Electronic DC Coil contacts.

    Voltages of 48V DC and greater are supplied with backpack module standard. See page A85.

    Not applicable with Electronic Timer accessories (CRZ_7).

    Coil Codes

    DC Coil Codes Voltage

    12E 12V

    24E 24V

    48E 48-72V

    110E 110-125V

    220E 220-250V

    Description

    Low Consumption Electronic DC coils have extremely low inrush

    which allows the use of smaller power supplies. CA7-9E43E have

    internal surge suppression. See page A68 for more information.

    This design results in:

    Lighter, lower depth

    More energy efcient contactors

    Easier wiring

    Uniform panel appearance

    Applications

    Direct control from PLC:

    The low power consumption contactor designed to control motors

    and other loads is especially aligned to the specic requirement of

    electronic control circuits. The low power consumption of 1.7 allows

    direct control through PLCs without the need for interposing relays.

    Power dissipation is greatly reduced limiting the heat effect in control

    panels.

    Coil Terminal PositionAll CA7 contactors are stocked and delivered with the coil terminals

    located on the line side (top) of the contactor. This is the typical

    conguration when using the contactor with an overload relay. When

    the contactor is used with the KT7 Motor Circuit Controller, the coil

    must be reversed, so that the coil terminals are located at the load

    side (bottom) of the contactor. CA7 coils can easily be reversed in the

    eld, however, they are also available for order with the coils reversed

    from the factory. Contact your Sprecher+Schuh representative for more

    information about ordering CA7 contactors with reversed coils.

    All CA7 contactors come withreversible coils.(48V DC shown)

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    7/19A36

    Contactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    Contactors - Two Winding DC Coil

    Three & Four Pole - Series CA7

    Non-Reversing, Three Pole Contactors With Two Winding DC Coil, Series CA7(Open type only)

    CA7-60DCA7-97D have an internal auxiliary contact to transition from the start windingto the run winding.

    Coils include an integrated diode surge suppressor.Other coil voltages are available, see page A57. Contact your Sprecher + Schuh Sales Rep-

    resentative to determine which coil voltages may be stocked.Non-standard coil voltages(non-stock) must be ordered and installed separately as renewal parts.

    The coil codes shown are the most commonly stocked items. Contact your Sprecher +Schuh representative to determine if other voltages, i.e.., 12DD, 48DD, 220DD are on-handor can be specially ordered in quantities.

    CA7-60D Contactor

    Description:

    Contactors with two

    winding DC coils have very

    low hold-in values and

    share the same dimensions

    with AC contactors. Seepage A57 for more informa-

    tion. See page A84 for

    dimensional information.

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4) AuxiliaryContacts per

    Contactor

    Open Type

    Catalog Number Price

    kW(50 Hz) UL/CSA HP(60 Hz)

    230V400V/415V 500V 690V

    1 3 AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    60 100 18.5 32 37 32 5 10 15 20 40 50

    0 0 CA7-60D-00- 475

    1 0 CA7-60D-10- 497

    0 1 CA7-60D-01- 497

    72 100 22 40 45 40 5 15 20 25 50 60

    0 0 CA7-72D-00- 530

    1 0 CA7-72D-10- 552

    0 1 CA7-72D-01- 552

    85 100 25 45 55 45 7-1/2 15 25 30 60 60

    0 0 CA7-85D-00- 590

    1 0 CA7-85D-10- 612

    0 1 CA7-85D-01- 612

    97 130 30 55 55 55 10 20 30 30 75 75

    0 0 CA7-97D-00- 757

    1 0 CA7-97D-10- 779

    0 1 CA7-97D-01- 779

    Coil Codes

    DC Coil Code Voltage

    24DD 24V

    110DD 110V

    Ordering Instruct ionsSpecify Catalog Number

    Replace () with Coil CodeSee Coil Codeson this page.

    Non-Reversing, Four Pole Contactors With Two Winding DC Coil, Series CA7(Open type only)

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4) Contact Con-

    figuration

    Main Pole

    AuxiliaryContacts per

    Contactor

    Open Type

    Catalog Number Price

    kW(50 Hz) UL/CSA HP(60 Hz)

    230V

    415V

    400V 500V 690V

    1 3

    AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC NO NC

    85 130 25 45 55 45 7-1/2 15 25 30 60 50 4 0 0 0 CA7-90D-M40- 781

    85 130 25 45 55 18.5 7-1/2 15 25 30 50 20 2 2 0 0 CA7-90D-M22- 781

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    8/19A37visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    CAU7-9-22-120 reversing contacto

    CAU7-43-22-120 reversing contact

    Reversing, Three Pole Contactors With AC Coil, Series CAU7(Open type only)

    For Reversing Contactors without power wiring add suffix -LW to catalog numband deduct the following amount:

    CAU7-923 deduct $10CAU7-3037 deduct $12CAU7-43 deduct $22

    CAU7-6097 without power wiring not availableEx: CAU7-9-22-becomes CAU7-9-22--LW.

    For control wiring, add suffix -CWto catalog number and add $20.Example: CAU7-9-22-becomes CAU7-9-22--CW.

    The NC auxiliary contacts are supplied as part of the mechanical interlock(Cat.# CM7-02) and are used to electrically interlock the contactors.

    The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliarycontacts must be special ordered. Contact your Sprecher+Schuh representative.

    Other voltages available, see page A56.Nonstandard coil voltages not listed here mbe ordered and installed separately as renewal parts.

    Contactors, AC Coil Reversin

    Three Pole - Series CAU

    Includes:

    Line side coil terminations Mechanical and electrical

    Interlock

    Reversing power wiring(using Power Wiring KitCat.# CAUT7-PW)

    Control wiring available; se

    footnote

    Coil Codes

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4) Auxiliary

    Contacts per

    Contactor

    Open Type

    Catalog

    Number Price

    kW(50 Hz) UL/CSA HP(60 Hz)

    230V

    400V

    415V 500V 690V

    1 3

    AC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 1 1 CAU7-9-22- 338

    12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 1 CAU7-12-22- 409

    16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 1 CAU7-16-22- 451

    23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 1 CAU7-23-22- 491

    30 65 10 15 15 15 2 5 7-1/2 10 20 250 1 CAU7-30-02- 553

    1 1 CAU7-30-22- 597

    37 65 11 18.5/20 20 8.5 3 5 10 10 25 300 1 CAU7-37-02- 640

    1 1 CAU7-37-22- 684

    43 85 13 22 25 22 3 7-1/2 10 15 30 300 1 CAU7-43-02- 710

    1 1 CAU7-43-22- 754

    60 100 18.5 32 37 32 5 10 15 20 40 500 1 CAU7-60-02- 895

    1 1 CAU7-60-22- 939

    72 100 22 40 45 40 5 15 20 25 50 600 1 CAU7-72-02- 1010

    1 1 CAU7-72-22- 1054

    85 100 25 45 55 45 7-1/2 15 25 30 60 600 1 CAU7-85-02- 1125

    1 1 CAU7-85-22- 1169

    97 130 30 55 55 55 10 20 30 30 75 750 1 CAU7-97-02- 1410

    1 1 CAU7-97-22- 1454

    AC Coil

    Code

    Voltage Range

    50 Hz 60 Hz

    24Z 24V 24V

    120 110V 120V

    208 ~ 208V

    220W 200V-220V 208V - 240V

    240 220V 240V

    277 240V 277V

    380 380V-400V 440V

    480 440V 480V

    600 550V 600V

    Ordering InstructionsSpecify Catalog Number

    Replace () with Coil CodeSee Coil Codeson this page.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    9/19

    A38

    Co

    ntactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    Contactors, Low Consumption Electronic DC Coil Reversing

    Three Pole - Series CAU7

    Reversing, Three Pole Contactors With Electronic DC Coil, Series CAU7(Open type only)

    For Reversing Contactors without power wiring add suffix -LW to catalog numberand deduct the following amount:

    CAU7-9E23E deduct $10CAU7-30E37E deduct $12Ex: CAU7-9E-22-24Ebecomes CAU7-9E-22-24E-LW.

    For control wiring, add suffix -CWto catalog number and add $20.Example: CAU7-9E-22-24Ebecomes CAU7-9E-22-24E-CW.

    The NC auxiliary contacts are supplied as part of the mechanical interlock(Cat.# CM7-02) and are used to electrically interlock the contactors.

    The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliarycontacts must be special ordered. Contact your Sprecher+Schuh representative.

    CA7-9E43E with electronic coils are not interchangeable with non-electronic DCor AC coils.

    See pages A47 for limitations. on adding auxiliaries to Electronic DC Coil contacts.Voltages of 48V DC and greater are supplied with backpack module standard. See

    page A85.Not applicable with Electronic Timer accessories (CRZ_7).

    CAU7-9E-22-24E Reversing contactor

    CAU7-37E-22-24E Reversing contactor

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4) Auxiliary

    Contacts per

    Contactor

    Open Type

    Price

    kW(50 Hz) UL/CSA HP(60 Hz)

    230V

    400V

    415V 500V 690V

    1 3

    Catalog NumberAC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 1 1 CAU7-9E-22- 484

    12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 1 CAU7-12E-22- 597

    16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 1 CAU7-16E-22- 629

    23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 1 CAU7-23E-22- 679

    30 65 10 15 15 15 2 5 7-1/2 10 20 250 1 CAU7-30E-02- 780

    1 1 CAU7-30E-22- 820

    37 65 1118.5/

    2020 8.5 3 5 10 10 25 30

    0 1 CAU7-37E-02- 971

    1 1 CAU7-37E-22- 1018

    43 85 13 22 25 22 3 7-1/2 10 15 30 30

    0 1 CAU7-43E-02- 1050

    1 1 CAU7-43E-22- 1090

    Description

    Low Consumption Electronic DC coils have

    extremely low inrush which allows the use of

    smaller power supplies. CA7-9E43E have

    internal surge suppression. See page A68 for more

    information.

    This new design results in:

    Lighter, lower depth

    More energy efcient contactors

    Easier wiring

    Uniform panel appearance

    Applications

    Direct control from PLC:

    The low power consumption contactor designed

    to control motors and other loads is especially

    aligned to the specific requirement of electronic

    control circuits. The low power consumption of

    1.7 allows direct control through PLCs without

    the need for interposing relays. Power dissipation

    is greatly reduced limiting the heat effect in

    control panels.

    Includes:

    Line side coil terminations

    Mechanical and electrical Interlock

    Reversing power wiring (using Power Wiring Kit

    Cat.# CAUT7-PW) Control wiring available; see footnote

    CAU7-9E43E has internal surge suppression.

    Coil Codes

    DC Coil Codes Voltage

    12E 12V

    24E 24V

    48E 48-72V

    110E 110-125V

    220E 220-250V

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    10/19A39visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    Contactors, DC Coil Reversin

    Three Pole - Series CAU

    Reversing, Three Pole Contactors With DC Coil, Series CAU7(Open type only)

    For control wiring, add suffix -CWto catalog number and add $20.Example: CAU7-60D-22-becomes CAU7-60D-22--CW.

    The NC auxiliary contacts are supplied as part of the mechanical interlock(Cat.# CM7-02) and are used to electrically interlock the contactors.

    The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliarycontacts must be special ordered. Contact your Sprecher+Schuh representative.

    Other voltages available, see page A57. Non-standard coil voltages not listed hermust be ordered and installed separately as renewal parts.

    Coils for CAU7-60D97D reversing contactors include an integrated diode surgesuppressor.

    Coil Codes

    CAU7-85D Reversing (Typical)

    NOTE: DC and AC coils are not interchangeable. CA7-60D97D contactors have a two winding, 3-leadcoil with built-in late break auxiliary contact and coil suppression. Refer to dimensions starting onpage A86.

    Includes:

    DC operating mechanism Line side coil terminations

    Mechanical and electricalInterlock

    Reversing power wiring Control wiring available; se

    footnote

    Ie[A]

    Ratings for Switching AC Motors (AC2 / AC3 / AC4) Auxiliary

    Contacts per

    Contactor

    Open Type

    Price

    kW(50 Hz) UL/CSA HP(60 Hz)

    230V400V415V 500V 690V

    1 3 Catalog

    NumberAC-3 AC-1 115V 230V 200V 230V 460V 575V NO NC

    60 100 18.5 32 37 32 5 10 15 20 40 500 1 CAU7-60D-02- 1115

    1 1 CAU7-60D-22- 1159

    72 100 22 40 45 40 5 15 20 25 50 600 1 CAU7-72D-02- 1240

    1 1 CAU7-72D-22- 1284

    85 100 25 45 55 45 7-1/2 15 25 30 60 600 1 CAU7-85D-02- 1360

    1 1 CAU7-85D-22- 1410

    97 130 30 55 55 55 10 20 30 30 75 750 1 CAU7-97D-02- 1745

    1 1 CAU7-97D-22- 1789

    DC Coil Code Voltage

    12DD 12V

    24DD 24V

    48DD 48V

    110DD 110V

    220DD 220V

    Ordering Instructions

    Specify Catalog Number

    Replace () with Coil CodeSee Coil Codeson this page.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    11/19A47visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    Accessories Field Installab

    CA7 Contacto

    Max. number of auxiliary contacts that may be mounted:

    AC Coil and Electronic DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, 2-N.O. contacts on the side, 4-N.C. front or side: 6 total.

    True DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, or max. 2-N.O. contacts on side, 4-N.C. front or side: 4 total.

    Detailed ratings can be found on page A74.

    Contact Block Description NO NC

    Contact

    Arrangement For use with...

    StandardContactsCatalog

    Number Price

    BifurcatedContactsCatalog

    Number Pric

    Auxiliary Contact Blocks forTop Mounting -

    2 and 4 pole

    Snap on design - mountswithout tools

    Electronic compatiblecontacts

    Mutual positive guidance tothe main contactor poles(excluding L types)

    Several terminal numberingchoices even for modelswit equal function

    Late break /early make (L)available

    Bifurcated Contacts

    Bifurcated auxiliary contacts

    provides a higher degree of

    reliability than the standardcross-stamped auxiliary

    contacts because it H-bridge

    divides each movable contact

    into two sections at the

    tip of the spanner. Typical

    application is low-voltage

    low-current applications

    (i.e.: PLC). Cross-stamped

    contacts are good for a mini-

    mum of 5mA at 17v while

    bifurcated contacts are good

    for a minimum of 3mA at 5v.

    0 252

    51

    62

    61

    CA7 all CS7-PV-02 27 CS7-PVB-02 42

    CA7-30...97--00 CA7-PV-02 27 CA7-PVB-02 42

    1 1

    54

    53

    62

    61

    CA7 all CS7-PV-11 27 CS7-PVB-11 42

    CA7-30...97--00 CA7-PV-11 27 CA7-PVB-11 42

    CA7-9...23--10CA7-PV-S11 27 CA7-PVB-S11 42

    CA7-9...23--01

    2 054

    53

    64

    63

    CA7 all CS7-PV-20 27 CS7-PVB-20 42

    CA7-30...97--00 CA7-PV-20 27 CA7-PVB-20 42

    1EM 1LB CA7-30...97--00 CA7-PV-L11 37 NOT AVAILABLE ~

    1 3

    54

    53

    62

    61

    72

    71

    82

    81

    CA7-30...97--00 NOT AVAILABLE ~ CA7-PVB-13 79

    2 2

    54

    53

    62

    61

    72

    71

    84

    83

    CA7 all CS7-PV-22 53 CS7-PVB-22 79

    CA7-30...97--00 CA7-PV-22 53 CA7-PVB-22 79

    22

    21

    32

    31

    44 54

    5343 CA7-9...23--10CA7-PV-S22 53 CA7-PVB-S22 79

    CA7-9...23--01

    3 154

    53

    62

    61

    74

    73

    84

    83

    CA7 all CS7-PV-31 53 CS7-PVB-31 79

    22

    21

    34

    33

    44

    43

    54

    53CA7-9...23--10

    CA7-PV-S31 53 CA7-PVB-S31 79CA7-9...23--01

    1 3

    54

    53

    62

    61

    72

    71

    82

    81

    CA7 all CS7-PV-13 53 CS7-PVB-13 79

    4 054

    53

    64

    63

    74

    73

    84

    83

    CA7 all CS7-PV-40 53 CS7-PVB-40 79

    0 4

    52

    51

    62

    61

    72

    71

    82

    81

    CA7 all CS7-PV-04 53 CS7-PVB-04 79

    1+1EM 1+1LB

    54

    53

    62

    61

    76

    75

    88

    87

    CA7 all CS7-PV-L22 74 NOT AVAILABLE ~

    Top mount auxiliary contactblocks snap-on to the top (front)

    of any CA7 contactor

    4-pole auxiliary

    2-pole auxiliarycontact block (typical)

    Top (Front) Mount Auxiliary Contact Blocks

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    12/19A48

    Contactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    Side Mount Auxiliary Contact Blocks (1 & 2 Pole)

    Max. number of auxiliary contacts that may be mounted:

    AC Coil contactors - max. 4 N.O. contacts on the front of the contactor, 2-N.O.

    contacts on the side, 4-N.C. front or side: 6 total.

    DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, or max.

    2-N.O. contacts on side, 4-N.C. front or side: (4) total.

    Left mounting only is recommended when using with CA7-9CA7-23 contactors.

    These contactors have built-in auxiliaries, which will result in duplicate terminal

    markings if mounted on the right.

    Detailed ratings can be found on page A74.

    Accessories Field Installable

    CA7 Contactors

    Contact Block Description NO NCContact

    Arrangement For use with... Catalog Number Price

    0 1 CA7 all CA7-PA-01 17

    1 0 CA7 all CA7-PA-10 17

    0 2 CA7 all CA7-PA-02 27

    1 1 CA7 all CA7-PA-11 27

    2 0 CA7 all CA7-PA-20 27

    1EM 1LB CA7 all CA7-PA-L11 37

    1-pole (typical)

    2-pole (typical)

    Auxiliary Contact Blocks for Side

    Mounting -

    1 and 2-pole

    Two way numbering for right or left

    mounting on the contactor

    Snap-on design - mounts without

    tools

    Electronic compatible contacts down

    to 24V, 20mA

    Late break / early make (L) available

    Mutual positive guidance to the main

    contactor poles (excluding L-types)

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    13/19

    A49visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    Accessories Field Installab

    CA7 Contacto

    Control Modules

    Module DescriptionFor usewith. . . Connection Diagrams Function Catalog Number Pric

    Pneumatic Timing Module The contacts in the Pneumatic TimingElement switch after the delay time. Thecontacts on the main contactor continueto operate without delay.

    Continuous adjustment range

    CA7 allON-Delay

    0.330s1.8180s

    CZE7-30

    CZE7-180

    160

    CA7 all OFF-Delay0.330s1.8180s

    CZA7-30CZA7-180

    160

    Electronic Timing Module ON-DelayThe contactor is energized at the end ofthe delay time.

    CA7 all

    110240V 50/60Hz110250V DC

    CRZE7-3-110/240CRZE7-30-110/240CRZE7-180-110/240

    980.13s130s10180s

    2448V DCCRZE7-3-24/48VDCCRZE7-30-24/48VDCCRZE7-180-24/48VDC

    1040.13s130s10180s

    Electronic Timing Module OFF-DelayAfter interruption of the control signal, thecontactor is de-energized at the end of thedelay time.

    CA7 all

    110240V 50/60Hz

    CRZA7-3-110/240CRZA7-30-110/240CRZA7-180-110/240

    1120.33s130s10180s

    CA7-9CA7-37

    24V AC 50/60Hz

    CRZA7-3-24VACCRZA7-30-24VACCRZA7-180-24VAC

    1120.33s130s10180s

    Electronic Timing Module Wye-Delta Transition TimerContactor K3 (Y) is de-energized andcontactor K2 (D) is energized after the endof the set transition time. Switching delayat 50ms.

    Continuous adjustment range High repeat accuracy

    CA7 all K1 (H) K2(D)

    K3 (Y)

    K1

    K2

    K3

    110240V 50/60HzCRZY7-30-110/240 112

    130s

    CM7 CM7-02

    Mechanical/Electrical Interlocks

    Common to all CA7 contactors;interlocks different contactor sizes

    Mechanical and electrical interlockingpossible in one module by means ofintegrated auxiliary contacts

    Dovetail (CA7-S9) connector included(9mm)

    CA7 all

    MechanicalWithout auxiliaries CM7

    34

    22

    21

    22

    21 Mechanical/ElectricalTwo NC aux contacts

    CM7-0240

    Not for use with CA7-40 or CA7-90 (4-pole) Contactors.

    Not available for use on CA7-9E43E coil voltage 48V220V.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    14/19

    A50

    Co

    ntactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    Control Modules(continued)

    Module DescriptionFor usewith

    ConnectionDiagrams Catalog Number Price

    Mechanical Latch Following contactor latching, the contactor coilis immediately de-energized by the NC auxiliarycontact (65-66).

    Electrical or manual release 1 NO + 1 NC auxiliary switch Suitable for all CA7 contactors

    CA7-997

    CV7-11-Replace withcoil code below(See ApplicationNote below)

    94

    Accessories Field Installable

    CA7 Contactors

    CV7 Mechanical Latch Coil Codes APPLICATION NOTE:The CV7 Mechanical Latch for CA7 may be used for both AC and

    DC applications; however when using DC control circuit the user

    must apply the following rules for coil selection of the contactorand latch combination:

    When DC control circuits are required use CA7-943

    contactors with AC coil and latch with AC coil. From column

    VDC in the table on the left, identify the required application

    DC control voltage and then select its specific Coil Code. Enter

    this Coil Code to complete the catalog numbers for both the

    contactor and latch (i.e.: 125V DC control circuit should use a

    240Z coil code in both the CA7-943 and CV7). This works

    because both coils are only momentary energized and coil

    clearing contacts breaks the circuit after closing or opening.

    The above statement does NOT apply to applications CA7-

    60D97D two-winding DC coil contactors. When DC control

    circuits are required use CA7-60D97D contactors withstandard two winding DC coil and the CV7 latch with AC coil

    selected from the table, top left. (i.e.: 125V DC control circuit

    should use 125DD coil code in the contactor and 240Z AC coil

    code in the CV7 latch).

    The CA7-9E43E contactor uses an electronic DC coil and the

    CV7 latch coil code should be chosen from the table on the left.

    (i.e.: 24V DC control circuit select CA7-9E43E with code 24E

    and CV7 latch uses a 48Z AC coil code).

    Coil

    Code

    Application Range Latch & Contactor Coil

    Rating50 Hz 60 Hz VDC

    24Z 24 VAC 24 VAC 12 VDC 24V 50/60 Hz

    48Z 48 VAC 48 VAC 24 VDC 48V 50/60 Hz

    110 100 VAC 110 VAC 48 or 60VDC 110V50/110V60

    120 110 VAC 120 VAC ~ 110V50/120V60

    220W ~ 208240 VAC ~ 208240V60

    230Z 230 VAC 230 VAC 110 VDC 230V 50/60 Hz

    240Z 240 VAC 240 VAC 125 VDC 240V 50/60 Hz

    277 240 VAC 277 VAC ~ 240V50/277V60

    380 380400 VAC 440 VAC ~ 380400V50/440V60

    400Z 400 VAC 400 VAC 220 VDC 400V 50/60 Hz

    415 400415 VAC ~ ~ 400415 V50 Hz

    480 440 VAC 480 VAC ~ 440V50/480V60

    600 550 VAC 600 VAC ~ 550V50/600V60

    Other voltages available. Contact your Sprecher + Schuh representative.

    CV7 must be wired for momentary operation only.

    Use 600V AC when 575 V is required.

    Command duration 0.0310 seconds.

    Coil operating limits on CV7-11 match those of the contactor it is being used with.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    15/19A51visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    Control Modules(continued)

    Module DescriptionFor usewith

    ConnectionDiagrams Function Catalog Number Price

    Electronic Interface

    Interface between the DC controlsignal from a PLC and the AC operatingmechanism of the contactor.

    Requires no additional surge suppres-sion for the coils

    Switching capacity 200VA

    Suitable for all CA7 contactors

    CA7 all(with ACcontrol)

    Input Output

    72

    24V DC 110 CRI7E-24

    12V DC 240V AC CRI7E-12

    48V DC CRI7E-48Indicates special order

    Surge Suppressors -Limits coil switching transients.

    Plug-in, coil mounted Suitable for all CA7 contactors

    CA7 all

    RC Module -AC Control (50/60Hz)

    2448V CRC7-4834

    110280V CRC7-280

    380480V CRC7-480

    Diode Module -DC Control

    3412-250VDC CRD7-250

    Varistor Module -AC/DC Control

    34

    1255VAC/1277VDC

    CRV7-55

    56136VAC/78180VDC

    CRV7-136

    137277VAC/181350VDC

    CRV7-277

    278575VAC CRV7-575

    Accessories Field Installabl

    CA7 Contactor

    Control voltage 1830V DC (1015mA)

    Minimum actuation current is 5 volts, 2ma. The leakage current is

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    16/19A52

    Contactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    Module Description

    Full-Wave Bridge Rectifier

    Catalog

    NumberPrice

    Module Input Module Output

    Control circuit voltage range

    For use with

    CA7 contactors with DC coilCS7 control relays with DC coil

    SEMI-F47-Module 24-250 VAC 24-250 VDC CA7-SF47 109

    Semi-F47-Module

    with 1...30s

    on-delay timer

    110-250 VAC 110-250 VDC CA7-SF47A30 175

    100

    90

    80

    70

    60

    5040

    30

    20

    10

    0

    0.05 0.1 0.2 0.5 1.0

    Duration of Voltage Sag in Seconds

    PercentageofEqui

    pmentNominalVoltage

    Semi-F47 Modules

    For CA7 Contactors

    AC Voltage Sag Immunity Modules

    Sprecher + Schuhs CA7-SF47 module meets the Semi-F47 AC voltage sag immunity requirements to 50% voltage sag for 200 ms. Voltage sags can affect

    the readiness and operation of contactors and starters, resulting in shut downs, lost production, and diminished revenue. It is essential for process equip-

    ment to be compatible with its electrical environment. The CA7-SF47 voltage sag immunity module is an essential component to achieve equipment reli-

    ability during voltage sag events.

    Product Features

    Meets Semi-F47 standard requirements

    For use with CA7 contactors and CS7 control relays

    with DC coils. A full-wave bridge rectifier internal to

    the CA7-SF47 module provides AC to DC coil voltage

    rectification.

    Suitable for contactor range (with screw terminals)

    - CA7-9 ... 97, 3-Pole contactors

    - CA7-9 ... 90, 4-Pole contactors

    Suitable for control relays (with screw terminals) - CS7

    Optional 1 to 30 seconds On-Delay timer function.

    Benefits

    Direct mounting to the coil terminals of the CA7

    contactors and CS7 control relays. Only 24 mm is added

    to the component height.

    Direct electrical connection to the contactor or control

    relay. Customer coil power connections are made at the

    terminals of the CA7-SF47 module

    The CA7-SF47A30 module includes a 1 to 30 seconds

    adjustable On-Delay timer in addition to the voltage sag

    immunity functionality. Two independent functions in a

    single module.

    VOLTAGE SAG DURATION VOLTAGE SAG

    Seconds Milliseconds Cycles at 60 hz Cycles at 50 hz Percent (%) of Equipment Nominal Voltage

    < 0.05 s < 50 ms < 3 cycles < 2.5 cycles Not specified

    0.05 to 0.2 s 50 to 200 ms 3 to 12 cycles 2.5 to 10 cycles 50%

    0.2 to 0.5 s 200 to 500 ms 12 to 30 cycles 10 to 25 cycles 70%

    0.5 to 1.0 s 500 to 1000 ms 30 to 60 cycles 25 to 50 cycles 80%

    > 1.0 s > 1000 ms > 60 cycles > 50 cycles Not specified

    Input AC control circuit voltage must be matched when selecting the contactor/relay DC coil voltage.

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    17/19A53visit www.sprecherschuh.com/ecatalog for the most up to date informationSSNA2012

    Discount Schedule A-1

    Terminal Lug Kits

    Paralleling Links

    cULus Approved (File E33916).

    Lighting applications are not considered purely resistive loads. Therefore, the IEC

    and UL/CSA resistive ratings listed here do not apply to lighting loads. Lighting

    contactor ratings are provided in the Technical Information section.

    Priced per piece. Total cost is package quantity x price. Minimum order, 3 pieces

    Engineering practice permits 2.5 x Ieto be applied to a contactor when 3 poles ar

    connected in parallel for single phase discharge lamp (ballast lighting) applicatio

    Component Description

    For use

    with . . .

    Maximum ResistiveCurrent Ratings (A)

    Pkg.

    Qty.

    Catalog

    Number

    Price

    EachIEC

    (40C)IEC

    (60C)UL/CSA(40C)

    3 Pole Lug Kit Allows larger wires to beused with the contactor. Idealfor wye-delta, reversing andmultispeed contactors andstarters. Can increase IECAC-1 current rating, as wellas the UL/CSA continuouscurrent (resistive) rating ofthe contactor. Three pole kitused for smaller contactors.

    CA7-9. . .23

    -line side

    -load side

    45 45 40 1CA7-P-KN23

    CA7-P-KL2341

    CA7-30. . .37 60 55 55 1 CA7-P-K37 56

    1 Pole Lug Kit Allows larger wires to be

    used with the contactor.Ideal for wye-delta, reversingand multispeed contactorsand starters. Can increaseAC-1 current rating of thecontactor. One pole kit usedfor larger contactors.

    CA7-43 90 75 75 3 CA7-P-K43

    28

    Each

    CA7-60 . . .97 130 130 130 3 CA7-P-K85

    33

    Each

    Component Description

    For use

    with . . .

    Maximum ResistiveCurrent Ratings (A)

    Pkg.

    Qty.CatalogNumber

    Price

    EachIEC

    (40C)IEC

    (60C)UL/CSA(40C)

    3 Pole Paralleling Link Allows smaller CA7contactors to be used onsingle-phase resistiveapplications. By parallelingthe three power poles, thecontacts see only a portion ofthe actual load.

    CA7-9. . .23 100 100 100 2 CA7-P-B23

    10

    Each

    CA7-30. . .37 150 135 150 2 CA7-P-B37

    15

    Each

    Quick Connectors

    Component Description For use with . . .

    Pkg.

    Qty. Catalog Number

    Price

    Each

    Stab Connectors -Dual stab (0.250 inch)

    CA7-997 coil term.CA7-923 power term.CA7 accessories

    20

    100

    100

    CA7-SC2CA7-SC10CA4-SC11

    1.75

    Accessories Field Installab

    CA7 Contactor Terminal Lug Ki

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    18/19A54

    Contactors

    A

    visit www.sprecherschuh.com/ecatalog for the most up to date information SSNA2012

    CA7

    Discount Schedule A-1

    Reversing Components

    Accessories Field Installable

    CA7 Contactors

    cULus Approved (File E33916).

    Component Description For Use WithPkg.Qty. Catalog Number

    PriceEach

    Dovetail Connectors Connects multiple contactor and starterassemblies together.

    CA7 all 10 CA7-S9 1.75

    Reversing Power Wiring Kit - Provides a solid wireless connectionfor reversing applications. May be usedwith both solid state and thermal O/Lrelays.

    CA7-912CA7-1623

    1 CAUT7-PW2317

    CA7-3037CA7-43CA7-6097

    1

    1

    1

    CAUT7-PW37CAUT7-PW43CAUT7-PW85

    20

    37

    94

    Reversing Power Wiring KitsOnly the kits are catalog items. Single components

    are available by special order in bulk packages of

    20 pieces.

    Assembly Components

    Component Description For Use WithPkg.Qty. Catalog Number

    PriceEach

    Protective Covers -Protects against unintended manualoperation.

    CA7 all 1

    CA7-SCC 3.35

    Protective Covers -For front mounted auxiliary contacts,pneumatic timers and latches.

    CS7-PV, CA7-PV,CZE7, CZA7, CV7

    1 CA7-SCF 1.75

    DIN-rail- 2 meter lengths ( 6' 6");

    price per rail

    Top Hat, low profile

    Top Hat, high profile

    CA7 all 20

    10

    3F3AF

    29

    44

    Marking Systems

    Component DescriptionPkg.Qty. Catalog Number

    PriceEach

    Label Sheet 1 sheet with 105 self-adhesive paperlabels each, 6 x 17mm

    1 CA7-FMS 1.75

    Marking Tag Sheet -1 sheet with 160 perforated paperlabels each, 6 x 17mm. To be used withtransparent cover.

    1 CA7-FMP 1.75

    Transparent Cover -To be used with Marking Tag Sheets.

    100

    CA7-FMC.17

    Tag Carrier -For marking with Clip-on Tags. SeeTerminals Section N for complete listingof Clip-on Tags.

    100

    CA7-FMA2.17

    CA7-60..97CA7-60..97

  • 8/9/2019 Sprecher Schuh CA7_Contactors.pdf

    19/19

    CA7-PWLM37 CA7-PWLM43

    CA7-PWLM85

    CA7-PWD43 CA7-PWD43

    CA7-PWD85

    2M S 2M S

    2M S

    C A7 -6 0. .9 7 C A7 -6 0. .9 7

    CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97 CA7-60..97

    cULus Approved (File E33916).

    Individual parts of kits are available for unique applications by special order. Contact your Sprecher + Schuh Representative.

    Accessories Field Installab

    CA7 Contacto

    Wye-Delta Starter Kits Wye-Delta power wiring kits were designed to aid in the field assembly of open-transition wye-

    delta starters that use CA7 contactors. These kits include line, load and start-point (shorting)

    connections. Assembling a wye-delta starter requires the use of the following components:

    Contactors and overload relay

    Mechanical / Electrical Interlock(Cat.No: CM7-02)

    Electronic Wye-delta Timer(Cat. No: CRZY7-30-110/240)

    Dovetail Connector to couple 1M and 2M contactor(Cat. No: CA7-S9); optional

    Three Contactor Assembly Components

    3-Phase Rating For 3 contactor

    assembly

    Catalog Number Price

    kW (50Hz) HP (60Hz) Use with catalog number . . .

    230V

    380V

    415V 500V 690V 200V 230V 460V 575V

    Delta Wye

    1M 2M 1S

    5.5 8 8 8 5 5 10 10 CA7-9 CA7-9 CA7-9

    CAYT7-PW23 227.5 11 11 11 5 7.5 15 15 CA7-12 CA7-12 CA7-9

    10 14 15 14 7.5 10 20 20 CA7-16 CA7-16 CA7-12

    14 21 21 19 7.5 10 25 25 CA7-23 CA7-23 CA7-12

    18 28 28 28 10 15 30 30 CA7-30 CA7-30 CA7-16CAYT7-PW37 27

    19 35 35 32 15 20 40 40 CA7-37 CA7-37 CA7-23

    23 40 40 41 20 25 50 50 CA7-43 CA7-43 CA7-30 CAYT7-PW43 44

    33 58 60 56 30 40 75 75 CA7-60 CA7-60 CA7-37CAYT7-PW72 79

    39 69 67 70 40 50 100 100 CA7-72 CA7-72 CA7-43

    47 82 82 81 50 60 125 125 CA7-85 CA7-85 CA7-60CAYT7-PW85 106

    50 90 90 90 50 60 125 125 CA7-97 CA7-97 CA7-60

    Two Contactor Assembly Components

    When Connecting... Load Side PowerConnection

    Catalog Number Price

    Shorting Bar

    CatalogNumber Price

    Delta Wye

    2M 1S

    CA7-30 CA7-30CA7-PWLM37 11 CA7-PWD43 14

    CA7-37 CA7-37

    CA7-43 CA7-43 CA7-PWLM43 18 CA7-PWD43 14

    CA7-60 CA7-60

    CA7-PWLM85 46 CA7-PWD85 23CA7-72 CA7-72

    CA7-85 CA7-85

    CA7-97 CA7-97

    Power Jumper Connection Shorting Bar

    Reversing Power Connection

    Two Contactor Wiring

    Connections are for

    Hydraulic Elevator Wye-

    Delta Contactors CA7Y2