H H
O
O
O
C l NH2
O
C l
C l
C l
C lC l
C l
OC l
NH2
O
C l
C l
C l
C lC l
C l
O
OOO
OO
OO
C l OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC lllllllllllllllllll NH2
O
CC ll
OOOOOOOOOOOOOOOOOOOOOOOOOOCCCC ll
NNNNNNNNNNHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH2222222222222222222222222222222222222222222222222222222222222222222222222222222
OOOOOOOOOOOOOOOOOOOOO
C l
C l
C l
CC lCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC llllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC llllllllllllllllllllllllllllll
Automated Canister and Tedlar® Bag Analysis.
Autosampler
I N S T R U M E N T S I N C .
The Most Flexible and AccurateLarge Canister and Tedlar® Bagsolution for EPA TO-14A and TO-15.
The new 7016D features 16 inlet positions that bring Entech’s automated
analysis capabilities to a wide variety of vacuum sampling canisters and
Tedlar® bags. The 7016D quickly connects to a 7200 Volatiles
Preconcentrator for automated analysis of VOCs in canisters to comply
with EPA Toxic Organics Methods TO-14A and TO-15.
The 7016D utilizes SmartLab™ 2A Windows® software and an all-new,
digitally controlled rotary valve actuator with “smart positioning” that
improves port alignment. Valve alignment is easy and no longer requires
rotation of the valve and tubing. All flow path tubing throughout the
7016D system is Silonite® coated and heated to further reduce flow path
carryover while maximizing sample recovery..
Your best solution for large canister and Tedlar® bag automated analysis.
The 7016D Autosampler
7016D Autosampler shown with 6L Canisters
Features
Automated AnalysisUp to sixteen 6L Silonite® canisters or Tedlar® bags can be
analyzed in accordance with EPA Methods TO-14A and TO-15.
Back-Flushing of Each Line After AnalysisUsing automated software control.
Automated Leak-CheckingVerification of leak-tight connections prior to opening valves.
Silonite® Coated Inlet LinesUltra-inert flow paths for recovery of reactive compounds.
Complete SmartLab™ 2A AutomationSophisticated Windows® compatible software with precise
automation control via USB connection.
Easy Valve AlignmentSimple adjustment of digital feedback sensor.
Expand yourCanister Analysis
Capabilities!
Call Us Today to Learn More!1
Automated AnalysisConnect up to three 7016D autosamplers to a
7200 Preconcentrator to easily analyze up to 48, 6L
Silonite® canisters or Tedlar® bags in accordance
with EPA Methods TO-14A and TO-15.
Automated Leak-Checking Verification of leak-tight connections prior to
opening valves.
7016D shown with 2.7L Canister Adapter7016D shown with 2.7L Canister Adapter
Silonite® Coated Inlet LinesUltra-inert flow paths ensure accurate
recovery of reactive compounds.
Up to three 7016D canister autosamplers can be simultaneously
connected to the 7200 Volatiles Preconcentrator.
Typical systems and connections are shown below.
7200 | 7650 | 7016D System Connections
MS GC 7650 Autosampler7200 Preconcentrator 7016D Autosampler
7200
CN
CN
O
Pum
pH
e/SP
VolumeDetermination
Reservoir
Inte
rnal
Sta
ndar
d
Cal
. Sta
ndar
d
1
23
4
56
1
23
4
5
6
7
8
2
11
2
1
2
3
468
C
CN
To P
ump
To P
ump
Exha
ust
Exha
ust
Rese
rvoi
r Iso
latio
n Va
lve
Rese
rvoi
r Ev
acua
tion
Valv
ePu
mp
Isola
tion
Valv
eFl
ow C
ontr
ol V
alve
GC
Car
rier
Gas
Sam
ple
1
Hel
ium
In
Deh
ydra
tion
Mod
ule 1
Col
d Te
nax®
Mod
ule 2
Focu
sing
Mod
ule 3
115
7
7200 PreconcentratorMS GC 7016D Autosampler
7200 | 7016D System Connections
The 7016D easily adapts for the
analysis of large canisters,
MiniCans™, and Tedlar® Bags.
7200
CN
CN
O
Pum
pH
e/SP
VolumeDetermination
Reservoir
Inte
rnal
Sta
ndar
d
Cal
. Sta
ndar
d
1
23
4
56
1
23
4
5
6
7
8
2
11
2
1
2
3
468
C
CN
To P
ump
To P
ump
Exha
ust
Exha
ust
Rese
rvoi
r Iso
latio
n Va
lve
Rese
rvoi
r Ev
acua
tion
Valv
ePu
mp
Isola
tion
Valv
eFl
ow C
ontr
ol V
alve
GC
Car
rier
Gas
Sam
ple
1
Hel
ium
In
Deh
ydra
tion
Mod
ule 1
Col
d Te
nax®
Mod
ule 2
Focu
sing
Mod
ule 3
115
7
6D7016 Autosammpler
Analyze up to 18 additional
canisters, bottles, or Tedlar® Bags
using the 7650’s expansion ports!
2
CCC lll
CC lll
CC ll
C lC l
CC l
O
O
C l
NH2
O
B r
C lCC l
C l
OOOC l
C l
C l
C lC l
C l
O
NN
NO
OC l
Learn more onl ineVisit us at www.entechinst.com
Entech Instruments, Inc.2207 Agate Ct.
Simi Valley, CA 93065Phone: 805-527-5939
7016D Autosampler –11.19.15v2a
7200Preconcentrator
4700Precision Diluter
5400BThermal Transfer System
3108DCanister Cleaning System
7650Canister Autosampler
The Recognized Global Leaders in Environmental Air Analysis.
© Entech Instruments, Inc. 2015. SmartLab™, MiniCan™, and Bottle-Vac™, are trademarks of Entech Instruments, Inc. Silonite® is a registered trademark of Entech Instruments, Inc. Tedlar® is a registered trademark of E. I. DuPont de Nemours & Company. Windows® is a registered trademark of Microsoft Corporation. All Rights Reserved.
Top Related