187-INSP - Belgium

12
Annex to the accreditation certificate Bijlage bij accreditatiecertificaat Annexe au certificat d'accréditation Beilage zur Akkreditierungszertifikat EN ISO/IEC 17020:2012 Version / Versie / Version / Fassung 10 Validity / Geldigheidsperiode / Validité / Gültigkeitsdauer 2021-04-01 - 2025-04-14 Maureen Logghe Chair of the Accreditation Board Voorzitster van het Accreditatiebureau La Présidente du Bureau d'Accréditation Vorsitzende des Akkreditierungsbüro 2274, Hongo, Ebina-shi 243-0494 Kanagawa-Ken Japan 243-0494 Kanagawa-Ken Japan Sites of activities / Activiteitencentra / Sites d'activités / Standorte mit aktivitäten: FBICC TEST LABORATORY 187-INSP The accreditation is granted to / De accreditatie werd uitgereikt aan / L'accréditation est délivrée à /Die akkreditierung wurde erteilt für: FUJIFILM BUSINESS INNOVATION Corp. 2274, Hongo, Ebina-shi

Transcript of 187-INSP - Belgium

Page 1: 187-INSP - Belgium

Annex to the accreditation certificateBijlage bij accreditatiecertificaat

Annexe au certificat d'accréditationBeilage zur Akkreditierungszertifikat

EN ISO/IEC 17020:2012

Version / Versie / Version / Fassung 10

Validity / Geldigheidsperiode /

Validité / Gültigkeitsdauer2021-04-01 - 2025-04-14

Maureen Logghe

Chair of the Accreditation Board

Voorzitster van het Accreditatiebureau

La Présidente du Bureau d'Accréditation

Vorsitzende des Akkreditierungsbüro

2274, Hongo, Ebina-shi243-0494 Kanagawa-Ken

Japan

243-0494 Kanagawa-KenJapan

Sites of activities / Activiteitencentra / Sites d'activités / Standorte mit aktivitäten:

FBICC TEST LABORATORY

187-INSP

The accreditation is granted to / De accreditatie werd uitgereikt aan /

L'accréditation est délivrée à /Die akkreditierung wurde erteilt für:

FUJIFILM BUSINESS INNOVATION Corp.2274, Hongo, Ebina-shi

isabelle.legrand
Belac
Page 2: 187-INSP - Belgium

Type B Inspection Body

- Open Area Test Site Verification of process and procedure for radio disturbance field

strength.- Anechoic Chamber Frequency range for evaluation of test facility and equipment:- Test Equipment - 30MHz to 1000MHz

- 1GHz to 18GHz

Electromagnetic compatibility: Verification of

-  Radiated emission measurement - facility and equipment for radiated emission of the

electromagnetic interference testing- measurement techniques, procedure and process in the

anechoic chamber or the Open Area Test Site (OATS)6/2

14/04/2015- 30MHz to 1000MHz- 1GHz to 18GHz

Electromagnetic compatibility: Verification of

-  Conducted emission measurement - conducted emission of the electromagnetic interference testing

- equipment/facility and measurement techniques, procedure and

process in the shielded enclosures.Frequency range for Conducted emission:

9kHz to 30MHz

Field of Inspection Type and Range of Inspection Methods and Procedures

CISPR Publication 11/ EN 55011

CISPR Publication 14-1 / EN 55014-1

CISPR Publication 16-1-2

CISPR Publication 16-2-1

CISPR Publication 22 / EN 55022

CISPR Publication 32 / EN 55032

FCC Part 15B

(47 CFR Chapter 15 subpart B)

IEC/EN 61000-6-3

IEC/EN 61000-6-4

CISPR 16-1-4

CISPR publication 22 / EN55022

CISPR publication 32 / EN 55032

ANSI C63.4

CISPR Publication 11/ EN 55011

CISPR Publication 14-1 / EN 55014-1

CISPR Publication 22 / EN 55022

CISPR Publication 32 / EN 55032

CISPR Publication 16-2-3

FCC Part 15B

(47 CFR Chapter 15 subpart B)

IEC/EN 61000-6-3

IEC/EN 61000-6-4

EBINA SITETable I

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 2/12

Page 3: 187-INSP - Belgium

Type B Inspection Body

Field of Inspection Type and Range of Inspection Methods and Procedures

Electromagnetic compatibility: Verification of

- Disturbance power measurement - disturbance power of the electromagnetic interference testing,

- equipment/facility and measurement techniques, procedure and

process in the shielded enclosures.Frequency range:

- 30MHz to 300MHz

Electromagnetic compatibility: Verification of

- Harmonic current emissions and voltage changes, voltage

fluctuations and flicker testing, - equipment/facility and measurement techniques, procedure and

process in public low-voltage supply system.Rated voltage:

220/380V, 230/400V and 240/415VFrequency:

50Hz and 60HzEquipment input current:

up to 75A

Electromagnetic compatibility: Verification of

- Electro static discharge immunity - electrostatic discharge immunity of the electromagnetic

compatibility testing, - equipment/facility and measurement techniques, procedure and

process.Competence of test personnel for the measurement

- Education, Training, Technical knowledge, skill and experience

- Harmonic current emissions and

voltage fluctuations and flicker

measurement in public low-voltage

supply system

IEC/EN 61000-4-2

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-2

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-2

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-2

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-2

IEC/EN 61000-3-2

IEC/EN 61000-3-12

IEC/EN 61000-3-3

IEC/EN 61000-3-11

CISPR Publication 14-1 / EN 55014-1

CISPR Publication 16-1-3

CISPR Publication 16-2-2

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 3/12

Page 4: 187-INSP - Belgium

Type B Inspection Body

Field of Inspection Type and Range of Inspection Methods and Procedures

Electromagnetic compatibility: Verification of

- radiated, radio-frequency electromagnetic field immunity

testing,- equipment/facility and measurement techniques, procedure and

process.Frequency range:

- 80MHz to 6GHz

Electromagnetic compatibility: Verification of

- electrical fast transient/burst immunity of the electromagnetic

compatibility testing, - equipment/facility and measurement techniques, procedure and

process.

- Radiated, radio-frequency

electromagnetic field immunity

- Electrical fast transient/burst

immunity

IEC/EN 61000-4-3

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-3

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-3

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-3

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-3

IEC/EN 61000-4-4

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-4

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-4

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-4

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-4

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 4/12

Page 5: 187-INSP - Belgium

Type B Inspection Body

Field of Inspection Type and Range of Inspection Methods and Procedures

Electromagnetic compatibility: Verification of

- surge immunity of the electromagnetic compatibility testing, - equipment/facility and measurement techniques, procedure and

process.

Electromagnetic compatibility: Verification of

- Electromagnetic immunity to conducted disturbances, induced

by radio-frequency fields testing, - equipment/facility and measurement techniques, procedure and

process.Frequency range:

- 150kHz to 80MHzCompetence of test personnel for the measurement

- Education, Training, Technical knowledge, skill and experience

- Surge immunity

- Electromagnetic immunity to

conducted disturbances, induced by

radio-frequency fields

IEC/EN 61000-4-5

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-5

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-5

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-5

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-5

IEC/EN 61000-4-6

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-6

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-6

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-6

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-6

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 5/12

Page 6: 187-INSP - Belgium

Type B Inspection Body

Field of Inspection Type and Range of Inspection Methods and Procedures

Electromagnetic compatibility: Verification of

- power frequency magnetic field immunity of the

electromagnetic compatibility testing,- equipment/facility and measurement techniques, procedure and

process.Frequency:

- 50Hz and 60HzCompetence of test personnel for the measurement

- Education, Training, Technical knowledge, skill and experience

Electromagnetic compatibility: Verification of

- voltage dips, short interruptions and voltage variations immunity

of the electromagnetic compatibility testing,

- equipment/facility and measurement techniques, procedure and

process.

- Power frequency magnetic field

immunity

- Voltage dips, short interruptions

and voltage variations immunity

IEC/EN 61000-4-8

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-8

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-8

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-8

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-8

IEC/EN 61000-4-11

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-11

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-11

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-11

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-11

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 6/12

Page 7: 187-INSP - Belgium

Type B Inspection Body

Field of Inspection Type and Range of Inspection Methods and Procedures

Electromagnetic compatibility: Verification of IEC / EN 61000-4-31

- AC mains ports broadband

conducted disturbance immunity test

- AC mains ports broadband conducted disturbance immunity of

the electromagnetic compatibility testing.

- equipment/facility and measurement techniques, procedure and

process.

Electromagnetic compatibility: Verification of IEC / EN 61000-4-39

- Radiated fields in close proximity -

Immunity test

- Radiated fields in close proximity immunity of the

electromagnetic compatibility testing

- equipment/facility and measurement techniques, procedure and

process.

Verification of

- intentional radiated frequency (RF) emission testing, - equipment/facility and measurement techniques, procedure and

process in the Fully Anechoic Chamber and semi anechoic

chamber.Frequency range:

- 9kHz to 30MHz (for short range device)- 30MHz to 18GHz

EN300330

EN302 291-2

FCC Part 15C

Intentional radiated frequency (RF)

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 7/12

Page 8: 187-INSP - Belgium

Type B Inspection Body

Electromagnetic compatibility - Radiated emission measurement: CISPR Publication 11/ EN 55011CISPR Publication 14-1 / EN 55014-1CISPR Publication 22 / EN 55022CISPR Publication 32 / EN 55032CISPR Publication 16-2-3FCC Part 15B(47 CFR Chapter 15 subpart B, ANSI C 63.4)IEC/EN 61000-6-3

IEC/EN 61000-6-4

Electromagnetic compatibility - Conducted emission measurement: CISPR Publication 11/ EN 55011

CISPR Publication 14-1 / EN 55014-1CISPR Publication 16-1-2CISPR Publication 16-2-1CISPR Publication 22 / EN 55022CISPR Publication 32 / EN 55032FCC Part 15B(47 CFR Chapter 15 subpart B, ANSI C 63.4)IEC/EN 61000-6-3

IEC/EN 61000-6-4

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

FXICC-20C003

FXICC-20C003

Type of inspections Standard and specificationsInternal reference

EBINA SITETable II

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 8/12

Page 9: 187-INSP - Belgium

Type B Inspection Body

Type of inspections Standard and specificationsInternal reference

Electromagnetic compatibility - Disturbance power measurement: CISPR Publication 14-1 / EN 55014-1CISPR Publication 16-1-3

CISPR Publication 16-2-2

IEC/EN 61000-3-2IEC/EN 61000-3-12IEC/EN 61000-3-3

IEC/EN 61000-3-11

Electromagnetic compatibility - Electro static discharge immunity: IEC/EN 61000-4-2 Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-2

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-2

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-2

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-2

Electromagnetic compatibility - Radiated, radio-frequency electromagnetic field

immunity:

IEC/EN 61000-4-3

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-3

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-3

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-3

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-3

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

FXICC-20C003

FXICC-20C003

FXICC-20C003Electromagnetic compatibility - Harmonic current emissions and voltage

fluctuations and flicker measurement in public low-voltage supply system:Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

FXICC-20C003

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 9/12

Page 10: 187-INSP - Belgium

Type B Inspection Body

Type of inspections Standard and specificationsInternal reference

Electromagnetic compatibility - Electrical fast transient/burst immunity:

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

Electromagnetic compatibility - Surge immunity:

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

FXICC-20C003

FXICC-20C003 IEC/EN 61000-4-4

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-4

CISPR 35 / EN55035 (partially)

portion that is relevant to IEC/EN 61000-4-4

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-4

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-4

IEC/EN 61000-4-5

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-5

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-5

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-5

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-5

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 10/12

Page 11: 187-INSP - Belgium

Type B Inspection Body

Type of inspections Standard and specificationsInternal reference

Electromagnetic compatibility- Electromagnetic immunity to conducted

disturbances, induced by radio-frequency fields:

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

FXICC-20C003 IEC/EN 61000-4-6

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-6

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-6

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-6

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-6

Electromagnetic compatibility - Power frequency magnetic field immunity:

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

FXICC-20C003 IEC/EN 61000-4-8

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-8

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-8

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-8

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-8

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 11/12

Page 12: 187-INSP - Belgium

Type B Inspection Body

Type of inspections Standard and specificationsInternal reference

Electromagnetic compatibility - Voltage dips, short interruptions and voltage

variations immunity:

IEC/EN 61000-4-11

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

CISPR 24 / EN55024 (partially) :

portion that is relevant to IEC/EN 61000-4-11

CISPR 35 / EN55035 (partially) :

portion that is relevant to IEC/EN 61000-4-11

IEC/EN 61000-6-1(Generic std.):

portion that is relevant to IEC/EN 61000-4-11

IEC/EN 61000-6-2(Generic std.):

portion that is relevant to IEC/EN 61000-4-11

Intentional radiated frequency (RF):

Inspections of test personnel approval for the measurement (Education, Training,

Technical knowledge, skill and experience)

FXICC-20C003

FXICC-20C003 EN300330

EN302291-2

FCC Part 15C

Annex/Annexe/Bijlage/Beilage BELAC 187-INSP V. 10 - 12/12