564144 Handbuch SAI D GB

33
SAI-Aktiv Line Modulbeschreibung SAI-Active-Line Modul Description

Transcript of 564144 Handbuch SAI D GB

  • SAI-Aktiv LineModulbeschreibung

    SAI-Active-LineModul Description

  • 3Installationsanweisungen4 - 5

    SAI-Aktiv Line1. SAI-Aktiv Line 42. Informationen fr den Anwender 53 So installieren Sie Ihr E/A-Modul der

    SAI-Aktiv Line I/O Module 63.1 Teilnehmeradresse einstellen 63.2 Modulmontage 73.3 E/A-Anschlussleitungen an das Modul

    der SAI-Aktiv Line anschlieen 83.4 PROFIBUS-Kabel anschlieen 9 - 103.5 Hilfsenergiekabel anschlieen 11

    4 Mit Ihrem PROFIBUS-Modul der SAI-Aktiv Line kommunizieren 12

    5 Probleme beheben mit Hilfe der LEDs 13 - 146 Spezifikationen 15 - 16

    Weidmller Support32 - 33

    Installation Instructions18 - 19

    SAI-Active Line1. SAI-Active Line 182. User Information 193 Install Your SAI-Active Line I/O Module 20

    3.1 Set the Station Address 203.2 Mount the Module 213.3 Connect the Input/Output Cord Sets

    to the SAI-Active Line Module 223.4 Attach PROFIBUS Cables 23 - 243.5 Attach Auxiliary Power Cable 25

    4 Communicate With Your SAI-Active Line PROFIBUS Module 26

    5 Troubleshoot with the Indicators 27 - 286 Specifications 29 - 30

    Weidmller Support32 - 33

    SAI-Aktiv LineModulbeschreibung

    SAI-Active-LineModul Description

  • 4Kapitel 1

    Installationsanweisungen 1 SAI-Active Line

    Bestellnummern:

    1864720000 SAI-A-M12-4-PB-8DI-L Profibus 8 Eingnge mit 4 x M12

    1864710000 SAI-A-M8-8-PB-8DI-L Profibus 8 Eingnge mit 8 x M8

    1864700000 SAI-A-M12-4-PB-8DO-L Profibus 8 0,5-Ausgnge mit 4 x M12

    1864690000 SAI-A-M8-8-PB-8DO-L Profibus 8 0,5A-Ausgnge mit 8 x M8

    1864680000 SAI-A-M12-4-PB-8DIO-L Profibus 8 frei whlbare Steckpltze fr Eingnge oderAusgnge mit 4 x M12

    1864670000 SAI-A-M8-8-PB-8DIO-L Profibus 8 frei whlbare Steckpltze fr Eingnge oderAusgnge mit 8 x M8

    Die SAI-Aktiv Line besteht aus 24 Vdc, Stand-Alone E/A-Modulen, die ber das PROFIBUS-Netz miteinan-der kommunizieren. Die in Schutzart IP67 ausgefhrten Module bentigen kein Gehuse. (Anmerkung:Gegebenenfalls bentigen Module, die der Schutzart IP67 nicht entsprechen, ein Gehuse;) E/A-Steckverbinder sind als umspritzte M8 (pico) oder M12- (micro) verfgbar, whrend die Steckverbinder frdie Hilfsenergie als M12 ausgefhrt sind.

    M8-Steck-verbinderM12-Steck-

    verbinder

  • 5Kapitel 2

    2 Wichtige Hinweise fr den Anwender

    Weidmller haftet in keinem Fall, weder bernimmt sie Verantwortung fr direkte Schden oder Folge-schden, noch fr Schden oder Folgeschden, die sich aus der Nutzung oder Verwendung dieser Moduleergeben knnten. Die in diesem Handbuch aufgefhrten Beispiele und Diagramme dienen allein demZwecke der Verdeutlichung. Auf Grund der Vielzahl der mglichen Variablen und Anforderungen, die imZusammenhang mit irgendeiner bestimmten Anlage stehen, kann Weidmller keine Verantwortung oderHaftung fr den tatschlichen Einsatz, der auf der Grundlage der hier aufgefhrten Beispiele zurckzufhrenist, bernehmen.

    Weidmller bernimmt keine patentrechtliche Haftung in Bezug auf die Beschreibung der in diesemHandbuch enthaltenen Informationen, Stromkreise, Module oder Software.

    Wichtige Hinweise fr den Anwender

    Weder komplett noch in Teilen darf dieses Handbuch ohne ausdrckliche schriftliche Genehmigung der Fa.Weidmller reproduziert werden. Hinweise in diesem Handbuch machen Sie auf sicherheitsrelevanteAspekte aufmerksam. Die so gekennzeichneten Hinweise geben Informationen ber Verhaltensweisen oderZustnde, die durch eine Explosion in einem explosionsgefhrdeten Bereich zu Personenschden oder zumTode bzw. zu Sachschden oder zum wirtschaftlichem Verlust fhren knnten. Die so gekennzeichnetenHinweise geben Informationen ber Verhaltensweisen oder Zustnde, die zu Personenschaden oder zumTode bzw. zu Sachschden oder zum wirtschaftlichem Verlust fhren knnten.

    Diese Hinweise helfen Ihnen

    Gefahren zu erkennen Gefahren zu vermeiden die Folgen abzuschtzen

    Die so gekennzeichneten Hinweise geben Information, die sowohl fr das Verstndnis als auch die erfolgrei-che Anwendung des Produkts von hchster Bedeutung sind. Auf der Auenseite bzw. im Inneren desModuls knnen Warnschilder auf das Anlegen gefhrlicher Spannungen aufmerksam zu machen.

    Umwelt und Gehuse

    Diese Module sind ohne Minderung der Betriebswerte fr den Einsatz in einer industriellen Umgebung mitseinem Verschmutzungsgrad 2, in Anwendungen der berspannungskategorie II (nach IEC 60664-1) und inHhenlagen von bis zu 2000 Meter vorgesehen. Gem IEC/CISPR Publikation 11 entsprechen dieseModule den Anforderungen der Gruppe 1, Klasse A.

    Ohne geeignete Vorsichtsmanahmen kann die elektromagnetische Vertrglichkeit in anderen Umgebungenauf Grund der leitungsgefhrten und abgestrahlten Strungen eventuell nicht gewhrleistet werden. DieseModule werden als "geschlossene" Module zur Verfgung gestellt. Werden sie in Umgebungen eingesetzt,die denen im Abschnitt Spezifikationen dieses Handbuchs aufgefhrten Gehusekenndaten entsprechen,ist ein zustzliches Gehuse nicht notwendig.

    Die nachfolgenden Abschnitte dieses Handbuches knnen zustzliche Informationen bezglich bestimmterGehusetypkenndaten enthalten, die diese Produkte nicht abdecken, die aber bei bestimmtenProduktsicherheitszertifizierungen erforderlich sind.

    ANMERKUNG: Erluterungen zum jeweiligen Schutzgrad der verschiedenen Gehusetypen finden Sie inden NEMA-Standards, Publikation 250, bzw. in der IEC-Publikation 60529.

    Verhindern elektrostatischer Entladung

    Diese Module sind empfindlich gegen elektrostatische Entladungen, die interne Schden verursachen unddie normale Funktionsweise beeintrchtigen knnen. Beachten Sie die folgenden Regeln beim Umgang mitdiesen Modulen:

    Berhren Sie einen geerdeten Gegenstand, um eventuelle elektrische Ladungen abzuleiten. Tragen Sie ein zugelassenes Erdungsband um das Handgelenk. Berhren Sie keine Steckverbinder oder Stifte auf der Leiterplatte. Berhren Sie keine Komponenten im Inneren des Moduls. Arbeiten Sie mglichst an einem vor statischer Entladungen gesichertem Arbeitsplatz. Bei Nichtverwendung, Lagern Sie die Module in einer geeigneten, anti-statischen Verpackung.

    Achtung

    Wichtig

    Wichtig

  • 6Kapitel 3

    So installieren Sie Ihr E/A-Modul der SAI-Aktiv Line

    Um Ihr Modul zu installieren, gehen Sie wie folgt vor:

    Teilnehmeradresse einstellen

    Modulmontage

    Anschlussleitungen anschlieen

    Netzkabel anschlieen

    mit dem Modul kommunizieren

    3.1 Teilnehmeradresse einstellen

    Die Teilnehmeradresse stellen Sie mittels der vorne am Modul angebrachten Drehschalter ein. DieDrehschalter stellen die hchstwertige Ziffer (MSD) und niedrigstwertige Ziffer (LSD) dar. Die Schalter knnenzwischen 00 und 99 eingestellt werden. Um die Einstellung vorzunehmen, muss Strom am Modul anliegen.

    Teilnehmeradresse einstellenIn diesem Beispiel ist die Teil- nehmeradresse auf 63 eingestellt.

  • 7Kapitel 3

    3.2 Modulmontage

    Das Modul ist mit Befestigungslchern versehen, um es direkt an eine Verteilertafel oder Maschine montie-ren zu knnen. Die Befestigungslcher sind fr M3 (#6) Flachkopfschrauben vorgesehen. Der vorgeschrie-bene Drehmomentwert ist 0.7 Nm. Wir empfehlen, die seitlich angebrachten Befestigungslcher nicht zuverwenden, da es keine Mglichkeit gibt das Modul zu erden.

    DAS MONTIEREN DES MODULS IN BEREICHEN MIT STARKEN VIBRATIONEN

    Es wird empfohlen sowohl eine flache Scheibe als auch einen Federring zu verwenden, wenn das Modul ineinem Bereich mit starken Schock- oder Vibrationenbelastungen eingesetzt werden soll. Setzen Sie dieScheiben, wie in der nachfolgenden Grafik gezeigt auf. Ziehen Sie die Schrauben mit einem Drehmomentvon 0.7 Nm an.

    19.8 mm (.78 in.)37 mm (1.46 in.)

    17 mm (.67 in.)

    179 mm(7.05 in.)

    168.6 mm(6.64 in.)

    166.5 mm(6.56 in.)

    27 mm (1.06 in.)

    43.3 mm(1.70 in.)

    32 mm(1.26 in.)

    32 mm (1.26 in.)

    43.3 mm (1.70 in.)

    Federring

    Unterleg-scheibe

  • 8Kapitel 3

    3.3 E/A-Anschlussleitungen an das Modul der SAI-Aktiv Line

    Module der SAI-Aktiv Line Familie bieten 5-polige M12, A-kodierte Steckverbinder (micro) oder 3-polige M8-Steckverbinder (pico).

    Im Zubehrprogramm sind Schutzkappen fr die nicht benutzten Steckverbinder sowie die dem entspre-chenden Steckverbinder.

    Die selbstkonfigurierenden Module (1864670000 und 1864680000) sin mit Eingangs- und Ausgangs-funktionalitt ausgestattet. Um einen E/A-Steckplatz als Ausgang zu verwenden, wird er mittels einesSteuerprogramms unter Strom gesetzt und so als Ausgang konfiguriert. Geschaltete Ausgnge haben einen entsprechenden aktiven Eingang, der als Einzelkanaldiagnose dienen kann, damit erkannt wird, dass der Ausgang eingeschaltet ist. Ist ein E/A-Steckplatz als Eingang vorgesehen, wird das Modul wiegewohnt verdrahtet und die Stromzufuhr zum entsprechenden Ausgang unterbunden.

    41452

    Selbstkonfigurierende Beschaltung E/A

    Ausgang einschalten

    Abfrageliste

    Eingang ist eingeschaltet(oder Ausgang ist eingeschaltet)

    Ausgangs- kreis

    Eingangs- kreis

    Modul

    Anschlussstift

    5-polige M12-Buchse, A-kodiertSteckverbinder Eingangsmodule186472000(Sicht von vorne)Pin 1 Spannungsversorgung SensorPin 2 Eingang 2Pin 3 GNDPin 4 Eingang 1Pin 5 Nicht belegt

    3-polige M8-BuchseSteckverbinder Eingangsmodule1864710000(Sicht von vorne)Pin 1 Spannungsversorgung SensorPin 3 GNDPin 4 Eingang 1

    5-polige M12-Buchse, A-kodiertSteckverbinder ModuleSelbstkonfigurierend1864680000(Sicht von vorne)Pin 1 Spannungsversorgung SensorPin 2 Eingang 2 oder Ausgang 2Pin 3 GNDPin 4 Eingang 1 oder Ausgang 1Pin 5 nicht belegt

    Steckverbinder fr Ausgangsmodule186470000(Sicht von vorne)Pin 1 nicht belegtPin 2 Ausgang 2Pin 3 GNDPin 4 Ausgang 1Pin 5 nicht belegt

    Steckverbinder fr Ausgangsmodule1864690000(Sicht von vorne)Pin 1 nicht belegtPin 3 GNDPin 4 Ausgang 1

    3-polige M8-BuchseModuleSelbstkonfigurierend 1864670000(Sicht von vorne)Pin 1 Spannungsversorgung SensorPin 3 GNDPin 4 Eingang 1 oder Ausgang 1

  • 9Kapitel 3

    Fr Konfigurationseinstellungen siehe das nachfolgende Diagramm.

    Unser Angebot an Kabeln und Anschlussleitungen, finden Sie im Weidmller-Katalog oder besuchen Sieunsere Homepage: http://www.weidmueller.com.

    Bentigen die an den Eingngen angeschlossenen Sensoren eine Energieversorgung der Klasse 2, mssendie Hilfsenergieverbindungen dieser Sensorik durch ein Netzgert der Klasse 2 gespeist werden.

    ACHTUNG

    Um die Schutzart IP67 zu gewhrleisten, stellen Sie sicher, dass alle Steckverbinder und Schutzkappenordnungsgem angezogen sind, damit keine undichten Stellen entstehen.

    E/A-Kabel sollten eine Lnge von 30 Metern nicht berschreiten.

    3.4 PROFIBUS-Kabel anschlieenDer 5-polige M12, B-kodierte Steckverbinder fr PROFIBUS ist wie nachfolgend dargestellt anzuschlieen.

    Um das Modul zu terminieren, verwenden Sie den zweiten PROFIBUS Steckverbinder zusammen mit einemAbschlusswiderstand (1784770000).

    ANMERKUNG: Verwenden Sie keinen PROFIBUS T-Verbinder mit Drosseln in Verbindung mitdiesen Modulen.

    PROFIBUS

    Teilnehmeradresse

    4 x -M12- oder 8 x -M8-E/A-Steckverbinder

    Status-LED

    Stromzufuhr Sensor/Aktor

    Alle E/As sind 24 Vdc beschaltet - 8 Eingnge- 8 Ausgnge- 8 Eingangs- oder Ausgangssteckpltze- Jede Kombination der 8 (z.B.: 7 x 1; 3 x 5)Ausgang kurzschlussgeschtzt

    Ausgangsberwachung bei 8 DIO Modulen

    Eingangssteckverbinder fr PROFIBUS

    (Sicht von vorne)Stift 1 +5 VdcStift 2 A SignalStift 3 GNDStift 4 B SignalStift 5 Schirm

    Ausgangsbuchse fr PROFIBUS

    (Sicht von vorne)Stift 1 +5 VdcStift 2 A SignalStift 3 GNDStift 4 B SignalStift 5 Schirm

    Achtung

  • 10

    Kapitel 3

    Montage des M12-Steckers

    Kabel durch Teile 1 bis 4 durchschieben. Zulssiger Durchmesser des Kabels: 6 bis 8 mm.

    Leiter abisolieren, die Schirmung ausweiten und um den Schirmring (Teil 4) herumwickeln. berflssigeUmflechtung abschneiden.

    Die Leiterenden nicht verzinnen. Wir empfehlen die Verwendung von Aderendhlsen.

    Litzen durch das Steckergehuse (5 und 6) schieben. Danach den Schirmring (Teil 4) Dichtungsring (Teil 3),Klemmelement (Teil 2) und Kappe (Teil 8) zusammenbauen. Kabel durch Festdrehen der Verschraubung (Teil 1)sichern. Litze mit Klemmschrauben sichern.

    Die brigen Teile wie in der Grafik dargestellt zusammenbauen. Anschlieend Verschraubung (Teil 1) undRndelschraube (Teil 7) festziehen.

    40 mm

    5 mm

    4 mm

    8

    5

    4 3 2 1

    6

    7

  • 11

    Kapitel 3

    3.5 Hilfsenergiekabel anschlieen

    Der 4-polige M12, B-kodierte Steckverbinder ist wie nachfolgend dargestellt anzuschlieen.

    Die Stifte fr die Stromzufuhr 1 und 2 sowie die Stifte 3 und 4 sind intern gebrckt. Um dieStrombelastbarkeit von 2 x 2 A zu erreichen, mssen die beiden Stifte miteinander verbunden werden.

    Stift 1 24 VdcStift 2 24 VdcStift 3 GNDStift 4 GND

  • 12

    Kapitel 4

    4 Mit Ihrem PROFIBUS-Modul der SAI-Aktiv Line kommunizieren

    Dieses Modul der SAI-Aktiv Line Produktfamilie fr PROFIBUS ist fr folgende Baudraten ausgelegt.

    SAI-A-M8-8-PB-8DIO-L and SAI-A-M12-4-PB-8DIO-L

    Bitte beachten Sie, dass die selbstkonfigurierenden Module SAI-A-M8-8-PB-8DIO-L und SAI-A-M12-4-PB-8DIO-L sowohl mit Eingangs- und Ausgangs-E/A-Funktionalitt ausgestattet sind. Es ist nicht notwendig diese Module zu konfigurieren.

    Um einen E/A-Steckplatz als Ausgang zu verwenden, wird er mittels eines Steuerprogramms unter Strom gesetzt und so als Ausgang konfiguriert.

    Ist ein E/A-Steckplatz als Eingang vorgesehen, wird das Modul, wie gewohnt verdrahtet und eineStromzufuhr zum entsprechenden Ausgang unterbunden.

    SAI-A-M12-4-PB-8DI-L und SAI-A-M8-8-PB-8DI-L

    SAI-A-M12-4-PB-8DO und SAI-A-M8-8-PB-8DO-L

    Baudrate Kabellnge

    9.6 KBPS 1000 m

    19.2 KBPS 1000 m

    45.45 KBPS 1000 m

    93.75 KBPS 1000 m

    187.5 KBPS 1000 m

    500 KBPS 400 m

    1.5 MBPS 200 m

    3 MBPS 100 m

    6 MBPS 100 m

    12 MBPS 100 m

    Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 00 E7 E6 E5 E4 E3 E2 E1 E00 A7 A6 A5 A4 A3 A2 A1 A0Wo: E = Eingang A = Ausgang

    Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 00 E7 E6 E5 E4 E3 E2 E1 E0Wo: E = Eingang

    Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 00 A7 A6 A5 A4 A3 A2 A1 A0 Wo: A = Ausgang

  • 13

    Kapitel 5

    5 Probleme beheben mit Hilfe der LEDs

    Dieses Modul hat folgende LEDs:

    Netzwerk- und Modul-Statusanzeige fr PROFIBUS

    Hilfsenergie-Anzeige

    Einzelne E/A-Status-Anzeigen fr die Ein- und Ausgnge

    M8-Steckverbinder

    Modul-Anzeige

    E/A-Statusanzeigen

    Netz-Anzeigen

    Hilfsenergie-Anzeige

    M12-Steckverbinder

    Modul-Anzeige

    E/A-Statusanzeigen

    Netz-Anzeigen

    Hilfsenergie-Anzeige

  • 14

    Kapitel 5

    Die nachfolgende Tabelle beschreibt die Netzstatus- und Modul-Anzeigen.

    Die nachfolgende Tabelle die Anzeige fr die Hilfsenergie.

    Die nachfolgende Tabelle beschreibt die einzelnen E/A-Statusanzeigen.

    LED Modul-LED Netz-LED (berwachungsgert (WD)-Status & DP-Status)

    Aus Keine Energiezufuhr Strom aus oder zum Modul WD-Status

    Baudrate-Suchmodus grn blinkend Nicht verwendet WD-Status:

    Baudratesuche beendet und DP-Status Kein Datenaustauschmodus

    grn, Modul funktioniert innerhalb DP-Status: leuchtet stetig normaler Parameter Kein Datenaustauschmodus rot, blinkend Behebbarer Fehler: Nicht verwendet

    ID-Nummer nicht bekanntrot, Nichtbehebbarer Fehler: Nicht verwendet leuchtet stetig - DPC31 ASIC-Fehler

    - EEPROM-Lese-/Schreibfehler

    Hilfsenergie Anzeigen StatusKeine Keine Hilfsenergie grn, leuchtet stetig Hilfsenergie liegt an

    E/A-Statusanzeigen Funktion Steckplatzanzeige Status Ausgnge Keine Kein Strom am Ausgang

    Gelb Strom liegt am Ausgang anEingnge Keine Keine gltige Eingabe

    Gelb Gltige Eingabe

  • 15

    Kapitel 6

    6 Spezifikationen

    SAI-Aktiv Line-ReiheEingangspezifikationen Max. Min.Eingnge 61131-2 Typ 3 kompatibelSensor Ausgangsstrom (pro Eingang) 50 mA -Sensor Ausgangsstrom (pro Modul) 400 mA -QuellsVersorgungspannung Sensor 30 V 11 V(Hilfsenergie = 12 bis 30 Vdc)1 Signal Spannung 30 Vdc 11 Vdc 1 Signal Strom 5 mA -0 - Signal Spannung 5 Vdc

    SAI-Aktiv Line-ReiheAusgangspezifikationen Max. Min.Ausgnge 61131-2 kompatibelAbschaltspannung - 30 VSpannungsabfall im Ein-Zustand 0.5 V -Ausgangsstrom (pro Ausgang) 0,5 AMax. Spannungsabfall im EIN-Zustand 50 A Ausgangsstrom (alle Ausgnge) 4,0 AMax. Stostrom fr 10 ms, wiederholbar alle 2 s 1,2 A

    PROFIBUS-SpezifikationenNetzwerk-Protokoll PROFIBUS-DP (EN50170) Kommunikation mit einem

    Master der Klasse 1.Kommunikation mit einem Master der Klasse 2.

    Redundanz Nicht untersttztRepeatersteuerungssignal RS485Implementierungstyp DPC31Freeze Modus UntersttztSynchronmodus UntersttztAuto-Baudrate UntersttztFailsafe-Modus UntersttztStationstyp DP-SlaveFMS-Untersttzung Nicht untersttzAnzahl der Stationen Maximal 100Kommunikationsrate / Lnge des Netzes 9,6 KBPS @ 1000 m

    19,2 KBPS @ 1000 m45,45 KBPS @ 1000 m93,75 KBPS @ 1000 m187,5 KBPS @ 1000 m500 KBPS @ 400 m1,5 MBPS @ 200 m3 MBPS @ 100 m6 MBPS @ 100 m12 MBPS @ 100 m

  • 16

    Kapitel 6

    Allgemeine Spezifikationen Isolierung typgeprft bis 500 Vac fr 60 Sekunden zwischen

    Hilfsenergie und Netz (E/A-Logik) Anzeigen Modulstatus - rot/grn, Netzstatus - rot/grn

    Hilfsenergie - grnSteckplatz LED - gelb

    Hilfsspannung Max.: 30 Vdc Min.: 11 Vdc Hilfsstrom Max.: 8DI 550 mA - - -

    Max.: 8DO 4 A Max.: 8DIO 4 A

    Betriebstemperatur IEC 60068-2-1 (Test Ad, Betriebszustand kalt), IEC 60068-2-2 (Test Bd, Betrieb, trockene Hitze), IEC 60068-2-14 (Test Nb, Betrieb, Temperaturschock): -20 bis 60 C (-4 bis 140 F)

    Lagertemperatur IEC 60068-2-1 (Test Ab, unverpackt Ruhezustand, Klte), IEC 60068-2-2 (Test Bb, unverpackt, Ruhezustand trockene Hitze), IEC 60068-2-14 (Test Na, unverpackt, Ruhezustand Temperaturschock): -45 bis 85 C (-49 bis 185 F)

    Relative Luftfeuchtigkeit IEC 60068-2-30 (Test Db, unverpackt, Ruhezustand, feuchte Wrme):5 bis 95% nicht kondensierend

    Stofestigkeit IEC60068-2-27 (Test Ea, unverpackt, Stoeinwirkung): Betrieb 30 g; Ruhezustand 50 g

    Vibrationsfestigkeit IEC60068-2-6 (Test Fc, Betrieb): 5 g bei 10 bis 500 Hz

    Strfestigkeit IEC 61000-4-2:6 kV Kontaktentladungen8 kV Luftentladungene

    Strfestigkeit bei abgestrahlten IEC 61000-4-3: Hochfrequenzstrungen 10 V/m mit 1 kHz Sinuswelle 80% AM von 30 MHz bis

    2000 MHz 10 V/m mit 200 Hz 50 % Impuls 100 % AM bei 900 Mhz 10 V/m mit 200 Hz 50 % Impuls 100 % AM bei 1890 Mhz

    EFT/B Strfestigkeit IEC 61000-4-4: 2 kV bei 5 kHz an Signalanschlssen 2 kV bei 5 kHz an Kommunikationsanschlssen 4 kV bei 2,5 kHz an Stromanschlssen

    berspannungsstrfestigkeit IEC 61000-4-5: 1 kV Phase-Phase (DM) und 2 kV Phase-Erde (CM) an Signalanschlssen 1 kV Phase-Phase (DM) und 2 kV Phase-Erde (CM) an Stromanschlssen 2 kV Phase-Erde (CM) an geschirmten Anschlssen

    Strfestigkeit bei leitungsgefhrten IEC 61000-4-6: Hochfrequenzstrungen 10 Veff mit 1 kHz Sinuswelle 80 % AM von 150 MHz

    bis 80 MHz Emissionen CISPR 11:

    Gruppe 1, Klasse A Gehuse IP67 (bei entsprechender Kennzeichnung) Zertifizierung (bei entsprechender c-UL-us: UL-gelistet als industrielles Steuerungsgert; Kennzeichnung des Produkts) fr US und Kanada zertifiziert.

    CE CE EMV-Richtlinie 89/336/EEC, entspricht:EN 61000-6-4; Strausendung im Industriebereich EN 50082-2; Strfestigkeit im Industriebereich EN 61326;elektrische Betriebsmittel fr Leittechnik undLaboreinsatz. Industrielle Anforderungen EN 61000-2;Strfestigkeit Industriebereich

    C-Tick: Australian Radiocommunications Act, nach:AS/NZS CISPR 11; Industrial Emissions(Industrielle Straussendungen)

  • 17

  • 18

    Chapter 1

    Installation Instructions 1 SAI-Active Line

    Catalouge Numbers:

    1864720000 SAI-A-M12-4-PB-8DI-L Profibus 8 Input with 4 x M12

    1864710000 SAI-A-M8-8-PB-8DI-L Profibus 8 Input with 8 x M8

    1864700000 SAI-A-M12-4-PB-8DO-L Profibus 8 0,5 Output with 4 x M12

    1864690000 SAI-A-M8-8-PB-8DO-L Profibus 8 0,5A Output with 8 x M8

    1864680000 SAI-A-M12-4-PB-8DIO-L Profibus 8 Selectable points Inputs or Outputs with 4 x M12

    1864670000 SAI-A-M8-8-PB-8DIO-L Profibus 8 Selectable points Inputs or Outputs with 8 x M8

    The SAI-Active Line family consists of stand-alone 24V dc I/O modules, which communicates via the PROFI-BUS network. The sealed IP67 housing of these modules require no enclosure. (Note that housing otherthan IP67 may require an enclosure.) I/O connectors are sealed M8 (pico) or M12 (micro) styles while thenetwork and auxiliary power connectors are sealed M12 style.

    M8 StyleConnectorsM12 Style

    Connectors

  • 19

    Chapter 2

    2 Important User Information

    In no event will Weidmller Interface be responsible or liable for indirect or consequential damages resultingfrom the use or application of this equipment.

    The examples and diagrams in this manual are included solely for illustrative purposes. Because of the manyvariables and requirements associated with any particular installation, Weidmller cannot assume responsibi-lity or liability for actual use based on the examples and diagrams.

    No patent liability is assumed by Weidmller Interface with respect to use of information, circuits, equipment,or software described in this manual.

    Important User Information

    Reproduction of the contents of this manual, in whole or in part, without written permission of Weidmller isprohibited.

    Throughout this manual we use notes to make you aware of safety considerations.

    Identifies information about practices or circumstances that can cause an explosion in a hazardous environ-ment, which may lead to personal injury or death, property damage, or economic loss.

    Identifies information about practices or circumstances that can lead to personal injury or death, propertydamage, or economic loss. Attentions help you:

    identify a hazard avoid a hazard recognize the consequence

    Identifies information that is critical for successful application and understanding of the product.

    Labels may be located on or inside the module to alert people that dangerous voltage may be present.

    Environment and Enclosure

    This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category IIapplications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters without derating.

    This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11.Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility inother environments due to conducted as well as radiated disturbance.

    This equipment is supplied as enclosed equipment. It should not require additional system enclosure whenused in locations consistent with the enclosure type ratings stated in the Specifications section of this publi-cation. Subsequent sections of this publication may contain additional information regarding specific enclo-sure type ratings, beyond what this product provides, that are required to comply with certain product safetycertifications.

    NOTE: See NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations ofthe degrees of protection provided by different types of enclosure.

    Preventing Electrostatic Discharge

    This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normaloperation. Follow these guidelines when you handle this equipment:

    Touch a grounded object to discharge potential static. Wear an approved grounding wriststrap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. If available, use a static-safe workstation.

    Attention

    Important

    Important

  • 20

    Chapter 3

    3 Install Your SAI-Active Line I/O Module

    To install the module:

    Set the station address

    Mount the module

    Connect the cord sets

    Attach the network cables

    Communicate with the module

    3.1 Set the Station Address

    To set the station address, adjust the switches on the front of the module. The two switches are most signi-ficant digit (MSD) and least significant digit (LSD). The switches can be set between 00 and 99. The modulereads the switches at power-up only.

    Set Node AddressThis example shows the defaultnode address set at 63.

  • 21

    Chapter 3

    3.2 Mount the Module

    The module has mounting holes that are used to mount the module directly to a panel or machine.Mounting holes accommodate M3 (#6) pan head screws. The torque specification is 0,7Nm (6 in-lbs). Wedo not recommend that you use the side mount holes with this module because there is no means to gro-und the module.

    Mount the Module in High Vibration Areas

    If the module will be mounted in an area that is subject to shock or vibration, it is recommended that youuse a flat and lock washer to mount the module. Mount the flat and lock washer as shown in the followingillustration. Torque the mounting screws to 0,7 Nm (6 in-lbs).

    19.8 mm (.78 in.)37 mm (1.46 in.)

    17 mm (.67 in.)

    179 mm(7.05 in.)

    168.6 mm(6.64 in.)

    166.5 mm(6.56 in.)

    27 mm (1.06 in.)

    43.3 mm(1.70 in.)

    32 mm(1.26 in.)

    32 mm (1.26 in.)

    43.3 mm (1.70 in.)

    Lock Washer

    Flat Washer

  • 22

    Chapter 3

    3.3 Connect the Input/Output Cord Sets to the SAI-Active Line Module

    The SAI-Active family offers 5 pin M12 (micro) A-Coded style PCB mounting connectors or 3 pin M8 (pico)style PCB mounting connectors.

    Caps are provided to cover the unused connectors on your module. Connect the quick-disconnect cordsets you selected to the appropriate ports.

    The self-configuring modules (1864670000 and 1864680000) contain both input and output I/O functionali-ty. If an I/O point is to be an output, dedicate that point as an output with a wired load and energize itthrough a control program. Energized outputs will show an associated active input, which can be used as afeedback mechanism to ensure that the output is turned on. If an I/O point is to be an input, wire the inputdevice as normal and leave the associated output un-energized at all times.

    41452

    I/O Self-configuring Circuitry

    Turn Output On

    Scan List

    Input is on(Or Output is on)

    OutputCircuit

    InputCircuit

    Device

    Connection Pin

    5-Pin M12 Female Connectors A-CodedInput Connector Modules186472000(view into socket)Pin 1 Sensor Source VoltagePin 2 Input 2Pin 3 ReturnPin 4 Input 1Pin 5 Not used

    3-Pin M8 Female ConnectorsInput Connector Modules1864710000(view into socket)Pin 1 Sensor Source VoltagePin 3 ReturnPin 4 Input 1

    5-Pin M12 Female Connectors A-CodedSelf-configuringConnector Modules1864680000(view into socket)Pin 1 Sensor Source VoltagePin 2 Input 2 or Output 2Pin 3 ReturnPin 4 Input 1 or Output 1Pin 5 Not Used

    Output Connector Modules186470000(view into socket)Pin 1 Not UsedPin 2 Output 2Pin 3 ReturnPin 4 Output 1Pin 5 Not used

    Output Connector Modules1864690000(view into socket)Pin 1 Not UsedPin 3 ReturnPin 4 Output 1

    3-Pin M8 Female ConnectorsSelf-configuringConnector Modules1864670000(view into socket)Pin 1 Sensor Source VoltagePin 3 ReturnPin 4 Input 1 or Output 1

  • 23

    Chapter 3

    Refer to the illustration below for configuration operations.

    Please refer to our catalogue for Weidmller cables and cord sets offerings or access the ConnectionSystems website at http://www.weidmueller.com

    IIf the devices (sensors) connected to the input connections require Class 2 power to operate, the auxiliarypower connections of this equipment must be powered by a Class 2 source.

    ATTENTION

    Make sure all connectors and caps are securely tightened to properly seal the connections against leaksand maintain IP67 requirements.

    I/O cable length should be less than 30 meters.

    3.4 Attach PROFIBUS Cables

    Attach the 5 pin (M12 B-Coded) PROFIBUS style connectors as shown below.

    To terminate the module, use the second PROFIBUS connector and a PROFIBUS terminator resistor (suchas 1784770000).

    NOTE: Do not use PROFIBUS T connectors with these modules.

    PROFIBUS

    Node Address

    4-M12 or 8-M8 I/OConnectors

    Status LED

    Sensor andActuator Power

    All I/O are 24 V dc sink in/source out- 8 input- 8 output- 8 input or output points - any mix of 8 (e.g., 7 x 1; 3 x 5)

    output short circuit protectedOutput monitoring in self-configuring style

    PROFIBUS Input Male Connector

    (view into pin)Pin 1 +5V dcPin 2 A SignalPin 3 GNDPin 4 B SignalPin 5 Shield

    PROFIBUS Output Female Connector

    (view into socket)Pin 1 +5V dcPin 2 A SignalPin 3 GNDPin 4 B SignalPin 5 Shield

    Attention

  • 24

    Chapter 3

    Plug assembly M12

    Push cable through parts 1 to 4. Permissible diameter of cable: 6 to 8 mm.

    Strip off the insulation, expand the shield, wrap it around the grading ring (part 4) and cut off the overhanging braiding.

    Do not tin-coat the wire ends. We recommend the usage of wire end ferrules.

    Push litz wires through the housing (part 5 and 6) and assemble grading ring (part 4), sealing ring (part 3),clamping element (part 2), and cap (part 8). Turn clamping screw (part 1) in order to fasten cable. Fasten litzwires with screws.

    Assemble remaining parts according to illustration, and tighten clamping screw (part 1) and knurled thumbscrew to part 7.

    40 mm

    5 mm

    4 mm

    8

    5

    4 3 2 1

    6

    7

  • 25

    Chapter 3

    3.5 Attach Auxiliary Power Cable

    Attach the 4 pin (M12 A-Coded) style connector as shown below.

    The power supply pins 1 and 2 as well as 3 and 4 are internally bridged. Both pins must be connected inorder to reach a current load-carrying capacity of 2 x 2A.

    Pin 1 24 VdcPin 2 24 VdcPin 3 ReturnPin 4 Return

  • 26

    Chapter 4

    4 Communicate WithYour SAI-Active Line PROFIBUS Module

    This SAI-Active Line PROFIBUS module has the following baud rates.

    SAI-A-M8-8-PB-8DIO-L and SAI-A-M12-4-PB-8DIO-L

    Note that the SAI-A-M8-8-PB-8DIO-L and SAI-A-M12-4-PB-8DIO-L self-assigning modules contain bothinput and output I/O functionality. These modules do not need to be configured.

    If an I/O point is to be an output, dedicate that point as an output with a wired load and energize it througha control program.

    If an I/O point is to be an input, wire the input device as normal and leave the associated output un-energi-zed at all times.

    SAI-A-M12-4-PB-8DI-L and SAI-A-M8-8-PB-8DI-L

    SAI-A-M12-4-PB-8DO-and SAI-A-M8-8-PB-8DO-L

    Baud Rate Cable Length

    9.6 KBPS 1000 m (3280 ft)

    19.2 KBPS 1000 m (3280 ft)

    45.45 KBPS 1000 m (3280 ft)

    93.75 KBPS 1000 m (3280 ft)

    187.5 KBPS 1000 m (3280 ft)

    500 KBPS 400 m (1312 ft)

    1.5 MBPS 200 m (656 ft)

    3 MBPS 100 m (328 ft)

    6 MBPS 100 m (328 ft)

    12 MBPS 100 m (328 ft)

    Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Produced 0 I7 I6 I5 I4 I3 I2 I1 I0Consumes 0 O7 O6 O5 O4 O3 O2 O1 O0Where: I = Input O = Output

    Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Produced 0 I7 I6 I5 I4 I3 I2 I1 I0Where: I = Input

    Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Consumes 0 O7 O6 O5 O4 O3 O2 O1 O0 Where: O = Output

  • 27

    Chapter 5

    5 Troubleshoot with the Indicators

    This module has the following indicators:

    Network and Module status indicator for PROFIBUS

    Auxiliary Power indicator

    Individual I/O status indicators for inputs and outputs

    M8 Style Connectors

    Module Indicator

    I/O Status Indicators

    Network Indicators

    Auxiliary Power Indicator

    M12 Style Connectors

    Module Indicator

    I/O Status Indicators

    Network Indicators

    Auxiliary Power Indicator

  • 28

    Chapter 5

    The following table describes network status and module indicators.

    The following table describes the auxiliary power indicator.

    The following table describes individual I/O status indicators.

    LED Is Module LED Network LED (Watchdog(WD) State & DP State)

    Off No module power Power off or WD_State Baudrate search mode

    Flashing Green Not used WD_State: Baudrate search complete and DP_State No Data Exchange mode

    Solid Green Module operating normal DP_State: Data Exchange mode

    Flashing Red Minor fault: Not usedUnknown Ident_Number

    Solid Red Unrecoverable fault: Not used - DPC31 ASIC fault- EEPROM Read/Write fault

    Auxiliary Power Indication StatusNone No Auxiliary Power Solid Green Auxiliary Power Present

    I/O Status Indicators Function Point Indicator Condition Outputs None Output not energized

    Yellow Output energizedInputs None No valid input

    Yellow Valid input

  • 29

    Chapter 6

    6 Specifications

    SAI-Active Line SeriesInput Specifications Max. Min. Inputs 61131-2 Type 3 CompatibleSensor Source Current (per input) 50 mA - Sensor Source Current (per module) 400 mA - Sensor Source Voltage 30 V 11 V(auxiliary power = 12-30 V dc)On-state Voltage 30 V dc 11 V dc On-state Current 5 mA - Off-state Voltage 5 V dc - Off-state Current

    SAI-Active Line SeriesOutput Specifications Max. Min. Outputs 61131-2 Compatible Off-state Peak Blocking Voltage - 30 V On-state Voltage Drop 0.5 V - On-state Current 0.5 A - Off-state Leakage 50 A - Module Current (all outputs) 4.0 A - Surge Current - for 10 ms, repeatable every 2 s 1.2 A -

    PROFIBUS SpecificationsNetwork Protocol PROFIBUS-DP (EN50170) Communication with a

    Class 1 master Communication with a Class 2 master Redundancy Not supported Repeater Control Signal RS485 Implementation Type DPC31 Freeze Mode Supported Sync Mode Supported Auto Baud Rate Supported Fail Safe Mode Supported Station Type DP Slave FMS Support Not Supported Number of Stations 100 maximum Network Length/ Communication Rate 9.6 KBPS @ 1000 m (3280 ft)

    19.2 KBPS @ 1000 m (3280 ft) 45.45 KBPS @ 1000 m (3280 ft) 93.75 KBPS @ 1000 m (3280 ft) 187.5 KBPS @ 1000 m (3280 ft) 500 KBPS @ 400 m (1312 ft) 1.5 MBPS @ 200 m (656 ft) 3 MBPS @ 100 m (328 ft) 6 MBPS @ 100 m (328 ft) 12 MBPS @ 100 m (328 ft)

  • 30

    Chapter 6

    General Specifications Isolation Type tested to 500 V ac for 60 seconds between auxiliary

    power and network (I/O to logic) Indicators Module Status - red/green Network Status - red/green

    Auxiliary Power - greenPoint LED - yellow

    Auxiliary Voltage 30 V dc max 11 V dc min Auxiliary Current 8DI 550 mA max - - -

    8DO 4 A max8DIO 4 A max

    Operating Temperature IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20 to 60C (-4 to 140F)

    Storage Temperature IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold), IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat), IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal Shock): 45 to 85C (49 to 185F)

    Relative Humidity IEC 60068-2-30 (Test Db, Un-packaged Non-operating Damp Heat): 5-95% non-condensing

    Shock IEC60068-2-27 (Test Ea, Unpackaged Shock): Operating 30 g Non-operating 50 g

    Vibration (unpackaged) IEC60068-2-6 (Test Fc, Operating): 5 g @ 10-500 Hz

    ESD Immunity IEC 61000-4-2: 6 kV contact discharge 8 kV air discharge

    Radiated RF Immunity IEC 61000-4-3: 10 V/m with 1 kHz sine-wave 80% AM from 30 MHz to 2000 MHz 10 V/m with 200 Hz 50 % Pulse 100 % AM at 900 Mhz 10 V/m with 200 Hz 50 % Pulse 100 % AM at 1890 Mhz

    EFT/B Immunity IEC 61000-4-4: 2 kV at 5 kHz on signal ports 2 kV at 5 kHz on communications ports 4 kV at 2.5 kHz on power ports

    Surge Transient Immunity IEC 61000-4-5: 1 kV line-line (DM) and 2 kV line-earth (CM) on signal ports 1 kV line-line (DM) and 2 kV line-earth (CM) on power ports 2 kV line-earth (CM) on shielded ports

    Conducted RF Immunity IEC 61000-4-6: 10 Vrms with 1 kHz sine-wave 80 % AM from 150 kHz to 80 MHz

    Emissions CSPR 11: Group 1, Class A

    Enclosure IP67 (when marked) Certifications: (when product is marked) c-UL-us UL Listed Industrial Control Equipment,

    certified for US and CanadaCE European Union 89/336/EEC EMC Directive,

    compliant with:EN 61000-6-4; Industrial EmissionsEN 50082-2; Industrial ImmunityEN 61326; Meas./Control/Lab. Industrial Requirements61000-6-2; Industrial Immunity

    C-Tick Australian Radiocommunications Act,compliant with:AS/NZS CISPR 11; Industrial Emissions

  • 31

  • Fr weitere Informationen und zustzliche technische Untersttzung bei der Installation, Konfiguration und Fehlersuche, nehmenSie bitte Kontakt mit der in Ihrem Land fr Sie zustndigen Weidmller-Vertretung oder Ihrer Vertretung vor Ort auf.

    32

    Aktivitten weltweit / Weidmller Support

    sterreich / AustriaWeidmller Ges.m.b.H.Industriezentrum N SdStrae 2, Objekt M22355 Wiener NeudorfTel. +43 2236 6708-0Fax +43 2236 [email protected]

    Jemen / YemenBitte kontaktieren Sie Weidmller Middle East Vereinigte Arabische Emirate / Please contactWeidmller Middle EastUnited Arab Emirates

    Australien / AustraliaWeidmller Pty. Ltd.43 Huntingwood DriveHuntingwood,NSW, 2148P.O.Box 6944BlacktownNSW, 2148Tel. +61 2 9671-9999Fax +61 2 [email protected]

    Belgien / BelgiumWeidmller N. V.Ambachtenlaan 11 A3001 HeverleeTel. +32 16 395990 Fax +32 16 [email protected]

    Bulgarien / BulgariaWeid-Bul eOOdul. Nezabravka 33 A, bl. 315/3/101113 SofiaTel. +359 2 9632560Fax +359 2 [email protected]

    Bosnien-Herzegowina /Bosnia-HerzegovinaBH ES Elektrosistem d.o.o.ul. J. Veselinovica 1878000 Banja LukaBosnaTel. +387 51 317500Fax +387 51 [email protected]

    Brasilien / BrazilConexel Conexoes Eltricas Ltda.Rua Garcia Lorca, 176- V. Paulicia, 09695-900, Sao Bernado do Campo - SP, BrasilTel. +55 11 43669600Fax +55 11 [email protected]

    Bahrain / BahrainKhayber Trading CompanyP.O. Box 1976 Manama, BahrainTel. +973 720 747Fax +973 720 [email protected]

    Weirussland / BelarusTehnikon Ltd.Apt. 704, Haus 16/5Oktiabrskaya Str. Minsk 220801Tel. +375 17 2275830Fax +375 17 [email protected]

    Kanada / CanadaW Interconnections Canada Inc.10 Spy Court, Markham, Ontario L3 R5 H6Tel. +1 905 475-1507Fax +1 905 [email protected] www.weidmuller.ca

    Schweiz / SwitzerlandWeidmller Schweiz AGRundbuckstrasse 28212 Neuhausen am RheinfallTel. +41 52 6740707Fax +41 52 6740708mail:[email protected]

    China / ChinaWeidmller Interface (Suzhou) Co. Ltd,Standart Factory Building 6,Area 3 of New Technology Park,Xiangyang Road No.81,Suzhou New District, Suzhou 215011 Jiangsu Province,P.R. China Tel. +86 21 50462384Fax +86 21 50462282www.cnweidmuller.com

    Kolumbien / ColumbiaAutomatizacion Avanzada S. A.Carrera 97 No. 42 A-23 B3, Santafe de Bogot Colombia.Tel. +57 1 4132048 Fax +57 1 [email protected]

    Costa Rica / Costa RicaELVATRON S.A.400 metros Norte de la Agencia delBanco de Costa Rica en la Uruca, San Jos, Costa RicaTel. +506 2 961060 Fax +506 2 326071 [email protected]

    Tschechien / Czech RepublicWeidmller s. r. o.Videnska ul. 34025242 Vestec u PrahyTel. +420 2 44001400Fax +420 2 [email protected]

    Deutschland / GermanyWeidmller GmbH & Co. KG(33 058) Postfach 28 07(33 102) An der Talle 89PaderbornTel. +49 5252 960-0Fax +49 5252 [email protected]

    Dnemark / DenmarkKnud Wexe A/SSkaettekaeret 11P.O. Box 1522840 HolteTel. +45 45465800Fax +45 45465801 [email protected]

    Spanien / SpainWeidmller S. A.Narcis Monturiol 11-13Pol.Ind. N 108960 Sant Just DesvernBarcelonaTel. +34 93 3722061Fax +34 93 [email protected] www.weidmuller.es

    El Salvador / El SalvadorBitte kontaktieren Sie ELVATRON S. A., Costa Rica /Please contactELVATRON S. A., Costa Rica

    Estland / EstoniaAlter Electric OTri 6, 11313 Tallinn, EstoniaTel. +372 65 19 666Fax +372 65 [email protected]

    gypten / EgyptStandard Electric5, Heliopolis Hospital Street, Cairo, EgyptTel. +20 2 6444182Fax +20 2 [email protected]

    Frankreich / FranceWeidmller Sarl12, Chausse Jules CsarB.P. 263 Osny95523 CERGY PONTOISE CedexTel. +33 1 34245500Fax +33 1 [email protected]

    Finnland / FinlandJUHA-ELEKTRO OYKylvpolku 6P. O. Box 5700681 HelsinkiTel. +358 9 478411Fax +358 9 47841311

    Grobritannien / United KingdomWeidmuller Ltd.1 Abbey Wood RoadKings HillWest MallingKent ME19 4YTTel. +44 1732 877032Fax +44 1732 [email protected]

    Guatemala / GuatemalaBitte kontaktieren Sie ELVATRON S. A., Costa Rica /Please contactELVATRON S. A., Costa Rica

    Griechenland / greeceVoltampere S.A.2nd Km., Lagada- Rendina57200 Lagadas-ThessalonikiTel. +30 3940 26188 Fax +30 3940 26189 [email protected]

    Ungarn / HungaryWeidmller Kereskedelmi KftDombvri t 13 1117 BudapestP. O. Box 221507 BudapestTel. +36 1 464-7888Fax +36 1 [email protected]

    Hongkong / Hong KongUnited Equity LimitedSuite B, 11/F International IndustrialCentre2-8 Kwei Tei Street, FotanShatin, N. T.Tel. +852 26876739Fax +852 26876735

    Jordanien / JordanBitte kontaktieren SieWeidmller Middle East Vereinigte Arabische Emirate / Please contactWeidmller Middle EastUnited Arab Emirates

    Honduras / HondurasBitte kontaktieren Sie ELVATRON S. A., Costa Rica / Please contactELVATRON S. A., Costa Rica

    Kroatien / CroatiaElektro Partner d.o.o.Radnicka cesta 2210000 ZagrebTel. +385 1 6184793Fax +385 1 6184795

    Italien / ItalyWeidmller S.r.l.Via Albert Einstein 420092 Cinisello BalsamoMilanoTel. +39 02 660681Fax +39 02 [email protected]

    Israel / IsraelA.U. Shay Ltd.Embar Street 23/25P.O.Box 10049Petach-Tikva 49222Tel. +972 3 9233601Fax +972 3 [email protected]

    Indien / IndiaWeidmller ReprsentanzbroVijay Dattani119, Prashanth ExtentionWhitefieldBangalore - 560 066Tel. +91 80 8453999Fax +91 80 8453999

    Iran / IranTAF Co.72, Iranshahr Av.Unit 5, TeheranTel. +98 21 831-7851Fax +98 21 [email protected]

    Irland / IrelandA.P. Haslam Ltd.14 Sunshine Ind. EstateCrumlin RoadDublin 12Tel. +353 1 453-2522 Fax +353 1 [email protected]

    Island / IcelandSamey Automation CenterLyngas 13, 210 Garoabaer,IslandTel. +354 510 5200Fax +354 510 [email protected]

    Japan / JapanNihon Weidmller Co. Ltd. Asahi Seimei Bldg. 11F1-14-1 Fuchucho Fuchu-shiTokyo 183-0055 JapanTel. +81 42 330-7891 Fax +81 42 330-7895www.weidmuller.co.jp

    Kuwait / KuwaitNOURI Industrial Establishment Co.P.O.Box 2829, Safat 13029 KuwaitTel. +965 4333355Fax +965 [email protected]

    Luxemburg / LuxembourgBitte kontaktieren Sie Weidmller Belgien, Heverlee /Please contactWeidmller Belgien, Heverlee

    Litauen / LithuaniaELEKTROS IRANGATinklu g.29a, 5319 Panevezys,LithuaniaTel. +370 45582828Fax +370 [email protected]

    Lettland / LatviaElektrosistemasKuldigas St. 51, 1046 Riga, LatviaTel. +371 7070140Fax +371 [email protected]

    LV

    LT

    L

    KWT

    J

    IS

    IRL

    IR

    IND

    IL

    I

    HR

    HO

    HKJ

    HK

    H

    GR

    GCA

    GB

    FIN

    F

    ET

    EST

    ES

    E

    DK

    D

    CZ

    CR

    CO

    CN

    CH

    CDN

    BY

    BRN

    BR

    BIH

    BG

    B

    AUS

    ADN

    A

    A Gruppenunternehmen / Group companies

    A Auslandsvertretung /Agency abroad

    A ohne eigene Vertretung /Without own Agency

  • 33

    Aktivitten weltweit / Weidmller Support

    For more information and for an additional level of technical support for installation, configuration and troubleshooting pleasecontact the Weidmller representive in your country or your local distributor.

    Marokko / MoroccoEnergy-Technics Transfer, S.A. 23 Boulevard Lieutnant Mohamed El Bakai TamriCasablanca 20250 Tel. +212 2 343700Fax +212 2 343699

    Malaysia / MalaysiaWeidmller (Malaysia) Sdn. Bhd.22 Jalan PJS 11/16 Bandar Sunway, 46150 Petaling Jaya, Selangor Darul EhsanTel. +60 3 56337363 Fax +60 3 56336562

    Mexiko / MexicoW Interconnections, S.A. de C.VAv. Ingenieros Civiles No. 204-B, Conjunto Industrial Chachapa72990 Chachapa, Puebla MexikoTel. +52 222 2866247/48/49Fax +52 222 [email protected]

    Mazedonien / MacedoniaES MK Elektrosistem d.o.o.Ul. Bulevar III makedonske brigade bb91000 SkopljeMacedoniaTel. +389 91 460295Fax +389 91 [email protected]

    Norwegen / NorwaySiv. Ing. J. F. Knudtzen A/SBillingstadsletta 971396 BillingstadP.O. Box 1601378 NesbruTel. +47 66 983350Fax +47 66 [email protected]

    Nicaragua / NicaraguaBitte kontaktieren Sie ELVATRON S. A., Costa Rica /Please contactELVATRON S. A., Costa Rica

    Niederlande / NetherlandsWeidmller B.V.Franciscusweg 2211216 SE HilversumPostbus 15051200 BM HilversumTel. +31 35 6261261Fax +31 35 [email protected]

    Neuseeland / New ZealandCuthbert S. Steward Limited27 Te Puni StreetPOB 38496 PetonePetone, WellingtonTel. +64 4 5686156Fax +64 4 5686056

    Oman / OmanBitte kontaktieren Sie Weidmller Middle East Vereinigte Arabische Emirate / Please contactWeidmller Middle EastUnited Arab Emirates

    Portugal / PortugalWeidmller - Sistemas de Interface, S. A.Estrada Outeiro Polima, Lote B, N B2, Escritrio 2 - Abboda2785-518 Sao Domingos de RanaTel. +351 21 4459190Fax +351 21 [email protected]

    Panama / PanamaBitte kontaktieren Sie ELVATRON S. A., Costa Rica /Please contactELVATRON S. A., Costa Rica

    Peru / PeruDIN AUTOMATIZACION S. A.Rimac Pampa 385 - MarangaLima 32Tel. +51 1 4511733Fax +51 1 [email protected]

    Pakistan / PakistanAccess Technology Networks(ATN) Pvt Ltd.No 47 College RoadSector F-7/2IslamabadTel. +92 51 275698Fax +92 51 275665

    Polen / PolandWeidmller Sp. z o.o.ul. Goledzinowska 1003-302 WarszawaPolandTel. +48 22 5100940Fax +48 22 5100941

    Katar / QatarBitte kontaktieren Sie Weidmller Middle East Vereinigte Arabische Emirate / Please contactWeidmller Middle EastUnited Arab Emirates

    Argentinien / ArgentinaCPI SABauness 26601431 Buenos AiresTel. +54 11 45238008Fax +54 11 [email protected]

    Taiwan / TaiwanFittatek Corp., Ltd.12 F No. 185 Fu-Kuo Rd, Tso Ying Dist, Kaohsiung, Taiwan R.O.C.Tel. +886 7556-0858 Fax +886 7556-3279

    Chile / ChileFelipe Bahamondes S.A./ATS AGROServicios AgroindustrialesMaria Luisa Santander 0475ProvidenciaCasilla 3425SantiagoTel. +56 2 341-1271Fax +56 2 [email protected]

    Indonesien / IndonesiaP. T. Nego ElectrindoKomplek Perkantoran Kramat CentreBlok-A 18 Jl Kramat Raya No. 7-9Jakarta 10450Tel. +62 21 3156218Fax +62 21 3156219

    Libanon / LebanonBitte kontaktieren Sie Weidmller Middle East Vereinigte Arabische Emirate / Please contactWeidmller Middle EastUnited Arab Emirates

    Rumnien / RomaniaROMINTERFACE IMPEX SRLSplaiul Unirii nr. 45, Bl. M 15sc. 3, ap. 68-69, Sect. 374342 BucurestiTel. +40 1 3220230Fax +40 1 [email protected]

    Sdkorea / South KoreaWeidmller (Korea) Co.,Ltd.Ocean tower 5F, 760-3, Woo-1dong, Haeundae-gu, Pusan Tel. +82 51 5564661 Fax +85 51 5567408

    Philippinen / PhilippinesTradepoints, Inc.3rd Floor PM Santiago Bldg.5081 P. Burgos Cor., San Mateo StreetsMakati ManilaTel. +63 2 8993294Fax +63 2 8993306

    Russland / RussiaWeidmller Reprsentanzbro Shabolovka street 2119049 Russia, MoskauTel. +7 095 771-6940Fax +7 095 [email protected]

    Schweden / SwedenWeidmller ABStockholm, Arenavgen 39, 12177 JohanneshovP.O. Box 1012012128 Stockholm-GlobenTel. +46 771 43 00 44Fax +46 8 [email protected]

    Saudi-Arabien / Saudi ArabiaAl Abdulkarim Trading P.O. Box 5777, Dammam 31432 Saudi ArabiaTel. +966 3 833-7110Fax +966 3 [email protected]

    Saudi-Arabien / saudi ArabiaSaudi Electric Supply Co.P.O. Box 3298, Al Khobar 31952 Saudi ArabiaTel. +966 3 882-9546227Fax +966 3 [email protected]

    Singapur / SingaporeWeidmller Pte. Ltd.Cititech Building629 Aljunied Road #05-05Singapore 389838Tel. +65 6841 5311Fax +65 6841 [email protected]

    Slowakei / SlovakiaElektris s.r.o.Racianska 188SK 83153 Bratislava, Slovakia Tel. +421 2 49200113Fax +421 2 [email protected]

    Slowenien / sloveniaELEKTROSPOJI d.o.o.Stegne 251000 LjubljanaTel. +38 6 15113810 Fax +38 6 [email protected]

    Syrien / SyriaBitte kontaktieren Sie Weidmller Middle East Vereinigte Arabische Emirate / Please contactWeidmller Middle EastUnited Arab Emirates

    Thailand / ThailandPisanu Engineering & Construction Co. Ltd. 800/2 Asoke-Dindaeng Road Dindaeng Bangkok 10400Tel. +66 2 2459113 Fax +66 2 [email protected]

    Trkei / TurkeyWeidmller Elektronik Ticaret Ltd.SirketiKore Sehitleri Cad. 34/1-780300 Zincirlikuyu IstanbulTel. +90 212 2730830Fax +90 212 [email protected]

    Ukraine / UcraineTEKO InterfacePer.Industrialny 203056 - KievTel. +380 04463 57760Fax +380 04463 [email protected]

    U.A.E. Vereinigte ArabischeEmirate / U.A.E. United Arab EmiratesWeidmller Middle-EastP.O. Box 62448DubaiTel. +971 4 3522215, 3523043Fax +971 4 3599950

    USA / USAW-Interconnections, Inc.821 Southlake Boulevard,Richmond, VA 23236Tel. +1 804 7942877Fax +1 804 [email protected]

    Vietnam / VietnamThien Nghi Trading Pte 60B Tan Da Street District 5 Ho Chi Min Tel. +84 8 8555387Fax +84 8 8549304

    Jugoslawien / YugoslaviaES YU Elektrosistem d.o.o.ul. Pariske komune 4111070 Novi BeogradSerbiaTel. +381 11 697212, 693608Fax +381 11 697212, [email protected]

    Venezuela / VenezuelaSomerinca C. A.Edificio Esteban Piso 2Calle Vargas Bolleita Notre Caracas 1070 AVenezuelaTel. +58 212 2352748Fax +58 212 [email protected]

    Sdafrika / South AfricaRAD Interface Pty. Ltd.5 Bundo RoadSebenza ExtensionEdenvale 1609P.O.Box 193Edenvale 1610Tel. +27 11 452-1930Fax +27 11 452-6455

    Andere Lnder / Other countriesWeidmller Interface GmbH & Co. KGPostfach 3030D-32720 DetmoldTel. +49 5231 14-0Fax +49 5231 14-20 [email protected]

    D

    ZA

    Y

    YU

    VN

    USA

    UAE

    UA

    TR

    T

    SYR

    SLO

    SK

    SGP

    SA

    SA

    S

    RUS

    RP

    ROK

    RO

    RL

    RI

    RCH

    RC

    RA

    Q

    PL

    PK

    PE

    PA

    P

    OM

    NZ

    NL

    NIC

    N

    MK

    MEX

    MAL

    MA

    A Gruppenunternehmen / Group companies

    A Auslandsvertretung /Agency abroad

    A ohne eigene Vertretung /Without own Agency

  • 34 We reserve the right to make technical changes Printed in Germany 5641440000 06/2004 DMMD