Elektronik Detonator

download Elektronik Detonator

of 51

Transcript of Elektronik Detonator

  • 8/12/2019 Elektronik Detonator

    1/51

    ELEKTRONIK

    DETONATOR

  • 8/12/2019 Elektronik Detonator

    2/51

    Elektronik Detonator

    i-konTM Digital Energy System

    UnitronikTMSystem

  • 8/12/2019 Elektronik Detonator

    3/51

    i-konTM Digital

    Energy System

  • 8/12/2019 Elektronik Detonator

    4/51

    i-konTM Digital Energy System

    Hardware

    - Detonator- Logger

    - Blaster

    Software- Shotplus-i

  • 8/12/2019 Elektronik Detonator

    5/51

    i-konTM Detonator

    Waktu delay detonator : 0 - 15000ms dengan beda 1ms

    Akurasi : +/- 0.1% dari waktu

    delay terprogram

    Detonator ID khusus Komunikasi dua arah

    Tidak terjadi overlap waktu

    delay

    Detonator kekuatan tinggi

    Aman terhadap over voltage,

    arus liar dan arus statis

    Memiliki konektor

  • 8/12/2019 Elektronik Detonator

    6/51

    i-konTM Detonator

    Sisi Power

    CapacitorSpark Gap

    Safety

    ResistorsBleed

    Resistor

    Fuse Head

  • 8/12/2019 Elektronik Detonator

    7/51

    i-konTM Detonator

    Sisi Kendali

    Electronic Chip

    Fuse headLeadWires

  • 8/12/2019 Elektronik Detonator

    8/51

    i-konTM Detonator ID

    Detonator ID

    Panjang lead wire

    Tanggal produksi

  • 8/12/2019 Elektronik Detonator

    9/51

    i-konTM Logger

    Sistem Pengaman < no-fire voltage

    no firing code

    Logging

    Verifikasi status detonator

    Membaca dan menyimpanDetonator ID dalammemory

    Menentukan waktu delay

    Testing

    Verikasi koneksi detonatordan harness wire

    Memberikan laporan error,kebocoran arus

    Kapasitas : 200 detonator

  • 8/12/2019 Elektronik Detonator

    10/51

    i-konTM Blaster

    Kunci Pengaman

    Komunikasi 2 arah

    Fungsi :

    Kalibrasi

    Pemrograman

    Laporan error

    Firing Kapasitas : 2 Logger (400

    detonator)

    i-konTMBlaster 400

  • 8/12/2019 Elektronik Detonator

    11/51

    i-konTM Blaster

    Kunci Pengaman

    Komunikasi 2 arah

    Fungsi :

    Kalibrasi

    Pemrograman

    Laporan error

    Firing

    Kapasitas : 8 Logger(1600 detonator)

    i-konTMBlaster 1600

  • 8/12/2019 Elektronik Detonator

    12/51

    Software Shotplus-i

    Desain peledakan untuklogging / pemrograman waktudelay

    Melakukan simulasi peledakandan analisa waktu peledakan

    Download data rencana loggingdan upload aktual logging darilogger ke komputer

  • 8/12/2019 Elektronik Detonator

    13/51

    Akurasi i-konTM Detonator

    Low

    numbers

    200 202 204198196

    .

    High numbers

    2000 2010 202019901980

    Pyrotechnic delays

    Electronics

    9000 ms

    9000 9001

    http://localhost/var/www/apps/conversion/tmp/scratch_6/popcorn-vs-hammer.mpg
  • 8/12/2019 Elektronik Detonator

    14/51

    Scatter Delay

    Benchtop400ms in-hole

    1% scatter = +/- 4ms

    0 17 34

    84 101

    42 59 76

    118 169152135

    12711093

    856851

    Nom In-Hole 417 434 451 468 485

    +1% 421 438 455 472 489

    -1% 413 430 447 464 481

    17ms => 9 - 25ms !

  • 8/12/2019 Elektronik Detonator

    15/51

    Sistem Safetyi-konTM Detonator

    Cull Test

    Orica S stem Inherent safet

    5v

    FieldTestVoltage

    10.5

    CulledNo-FireVoltage

    12.5 v

    All fire

    25v

    FirinVoltage

  • 8/12/2019 Elektronik Detonator

    16/51

    Logging i-konTM Detonator

    1

    198

    200

    199

    2

    Logging det# 1Logging det# 2Logging det# 198Logging det# 199Logging det# 200

    LOGGER

    +/-BATT

    LOGGER

  • 8/12/2019 Elektronik Detonator

    17/51

    Logging i-konTM Detonator

    +/-BATT

    LOGGERNo. ID-number delay time

    2 D23A66 25 ms

    200 B02457 5000 ms

    3 C01E44 50 ms

    .

    ..

    .

    .

    ..

    .

    .

    ..

    .

    1 F00B24 0 ms

    DET# 1 INC: 25

    0 ms 0

    DET# 2 INC: 25

    0 ms 25

    DET# 3 INC: 25

    25 ms 50

    DET# 200 INC: 25

    4975 ms 5000

  • 8/12/2019 Elektronik Detonator

    18/51

    Shotplus-i Logging

  • 8/12/2019 Elektronik Detonator

    19/51

    Shotplus-i Logging

  • 8/12/2019 Elektronik Detonator

    20/51

    Shotplus-i Upload

  • 8/12/2019 Elektronik Detonator

    21/51

    Firing i-konTM Detonator

    Blaster Connection and Firing

    LOGGER LOGGER LOGGER LOGGER LOGGER LOGGER LOGGER LOGGER

    BLASTER>Testing...

    >Calibrating

    >Programming...

    KEY

    FIRE FIRE

    READY TOFIRE

    >PRESS BOTH FIRE BUTTONSTOSTART BLAST SEQUENCE

    >REMOVE KEY TOSHUTDOWN BLASTER

  • 8/12/2019 Elektronik Detonator

    22/51

    i-konTM Digital Energy System

    Fragmentasi

    WallControl/Presplitting

    Backbreak Lingkungan (Vibrasi)

    Pemisahan

    Ore/Waste Throw/Lemparan

    Pengaturan WaktuDelay

    Expand Pattern

    Produksi Biaya

  • 8/12/2019 Elektronik Detonator

    23/51

    Fragmentasi

  • 8/12/2019 Elektronik Detonator

    24/51

    FragmentasiSize Distribution for i-kon Pattern Expansion trials

    0%

    10%

    20%

    30%

    40%

    50%

    60%

    70%

    80%

    90%

    100%

    0.000 0.100 0.200 0.300 0.400 0.500 0.600

    Size (m)

    PercentPassing

    Exel

    i-kon std

    i-kon exp

    Exel: Good Fragmentation

    i-kon #1: Better Fragmentation

    i-kon #2: Expanded pattern,better Fragmentation

  • 8/12/2019 Elektronik Detonator

    25/51

    Wall Control /

    Presplitting

  • 8/12/2019 Elektronik Detonator

    26/51

    Presplitting Nonel Detonator

  • 8/12/2019 Elektronik Detonator

    27/51

    Presplitting I-konTMDetonator

  • 8/12/2019 Elektronik Detonator

    28/51

    Back Break

  • 8/12/2019 Elektronik Detonator

    29/51

    Desain Shotplus-i

  • 8/12/2019 Elektronik Detonator

    30/51

    Post Blast i-konTM

  • 8/12/2019 Elektronik Detonator

    31/51

    Post Blast Nonel Detonator

  • 8/12/2019 Elektronik Detonator

    32/51

    Pemisahan

    Ore/Waste

  • 8/12/2019 Elektronik Detonator

    33/51

    Pre Blast i-konTM

  • 8/12/2019 Elektronik Detonator

    34/51

    Desain Shotplus-i

  • 8/12/2019 Elektronik Detonator

    35/51

    Post Blast i-konTM

  • 8/12/2019 Elektronik Detonator

    36/51

    Pre Blast i-konTM

  • 8/12/2019 Elektronik Detonator

    37/51

    Desain Shotplus-i

    High grade

    High grade

    Low grade

  • 8/12/2019 Elektronik Detonator

    38/51

  • 8/12/2019 Elektronik Detonator

    39/51

    Throw /

    Lemparan

  • 8/12/2019 Elektronik Detonator

    40/51

    New timing:

    C.o.M. 60 % further

    Std. timing

  • 8/12/2019 Elektronik Detonator

    41/51

    Modified EBS System

    Standard System

  • 8/12/2019 Elektronik Detonator

    42/51

    Lingkungan

    (Vibrasi)

  • 8/12/2019 Elektronik Detonator

    43/51

    Nonel Detonator

  • 8/12/2019 Elektronik Detonator

    44/51

    i-konTMDetonator

    i k

  • 8/12/2019 Elektronik Detonator

    45/51

    i-konTM

    Introduction Video

    http://localhost/var/www/apps/conversion/tmp/scratch_6/Ikon%20Introducing.mpg
  • 8/12/2019 Elektronik Detonator

    46/51

    UnitronikTM

    System

  • 8/12/2019 Elektronik Detonator

    47/51

    UnitronikTM System

    Detonator

    Scanner

    Network Tester

    Blast Box

  • 8/12/2019 Elektronik Detonator

    48/51

    UnitronikTM Detonator

    Waktu delay detonator : 0

    - 10000 ms dengan beda

    1ms

    Akurasi : +/- 0.1% dariwaktu delay terprogram

    Detonator ID khusus

    Aman terhadap over

    voltage, arus liar dan arus

    statis

  • 8/12/2019 Elektronik Detonator

    49/51

    UnitronikTM Scanner

    Pasif Scanning

    Kapasitas 400

    detonator

    U i ikTM N k

  • 8/12/2019 Elektronik Detonator

    50/51

    UnitronikTM Network

    Tester Test koneksi detonator

    Test status deonator

    Test kebocoran arus

  • 8/12/2019 Elektronik Detonator

    51/51

    UnitronikTM Blast Box

    Kunci Pengaman

    Komunikasi 2 arah

    Pemrogramandetonator

    Kapasitas 400detonator