Schnitt A-A - cibeslift.com unit 16... · Freimaßtoleranzen DIN 7168 fein mittel grob Oberfläche...
Transcript of Schnitt A-A - cibeslift.com unit 16... · Freimaßtoleranzen DIN 7168 fein mittel grob Oberfläche...
Freimaßtoleranzen
DIN 7168
fein mittel grob
Oberfläche
DIN 1302
Reihe 5
Urheberschutz nach DIN 34Jede Vervielfältigung, Nachbau oder
Weitergabe an Dritte ist untersagtoder bedarf unserer schriftlichen
Genehmigung.
Format DIN A0
Datum Name
Gez.
Gepr.
Pichler
Dateiname:
a
b
c
d
e
f
g
Index Änderung Datum Name
Fläche Gewicht
Maßstab
WerkstoffOberfläche
19.02.2016
lift unit 16-0040.dft
0,000 kg
SFI16-0040 lift unit "Hissipörssi, Helsingin"
A
B
C
D
E
F
8 7 6 5 4 3 2 1
G
H
11 10 912
I
J
K
L
B
C
D
E
F
G
H
I
J
K
L
13141516
8 7 6 5 4 3 2 111 10 91213141516
servelift gmbh
A-4161 Ulrichsberg Tel. +43(0)7288/27120 Kreuzlandl 3 Fax.+43(0)7288/27120-20 www.servelift.com [email protected]
A A
B
B
Schnitt B-B
Schnitt A-A
1400
1100
10158010
1600
1014
655
100
20
3810
2425
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
10mmlaminatedglass
aluminium panel aluminium panel aluminium panel
3510
50100
460
Hereby I accord with the drawing and all measurments and texts,and confirm the drawing for production.
date / signature:...............................................................................................
emergency wheel (demountable)
electrical switchbox:- RAL 7035- approx: 600x800x250mm- mounted in a max. distance of 5m to the electric engine- with heating element
platform control:- lighted emergency shutdown- button "0" and "1"- emergency telephone with GSM- key locking
call station:- key switch- call button
call station:- key switch- call button
shaft ventilation
max. tensile-/pressure loadingapprox. 3,5-4,5kN each fixing point
max. foundation load in the area of the lift guide (706x230mm) approx. 10kN;under suspension of a force of impact of 5 approx. 50kN
max. foundation at the shaft floor approx. 10kN
Electrical requirements for installation site: Mandatory requirements for installation site according to VdTÜV leaflet Elevators 103 or EN 81-41:2004:
- Socket outlet 230V /50Hz protected minimum. B13 for maintenance work near to the lowest station.
- Error current - sensitive to universal current– protection (FI) with minimum >= 30mA release current.
- Main switch with 2 poles, minimum 25A to disconnect all poles of the main power supply (supply line). This switch must be lockable and is exclusively installed fort he power supply of the elevator. The power supply for lighting and socket outlet must remain life for maintenance work.
- Overvoltage protection device type „C“ to protect against external overvoltage from the supply line. (to be installed in the house terminal resp. the nearest sub-terminal.
- Grounding for potential equalisation minimum 4mm². - Maximum grounding resistance: 3 ohm - Lightning protection is necessary for outdoor installation of the elevator.. - empty tube minimum 80 mm diameter from electrical cabinet to lift guide
- Only for installations with isolated neutral point ( IT-nets): Cut-off transformer
minimum approx. 4000VA. Additional requirments:
- For externally mounted calling stations : empty tube minimum 25 mm diameter (from electrical cabinet to first door, from 1st door to 2nd door, … and so on … - No grounding necessary. (low voltage). - For optional emergency telephone a connection cable with min. 4x0,25 mm² is
necessary to the position of the electrical switch box!
Electrical characteristics: Nominal voltage: 230V / 50Hz Nominal current: 8,5 A Max. current consumption: 16,4 A shortterm Nominal power (Frequency Converter): 2,2 kW Cross section: Min. 3x2,5 mm² Pre-fuse: Min. C25 Control voltage: 24Vdc – short curcuit proof
servelift V10: outdoor unit- platform size 1100x1400mm- max. load capazity 385kg- smooth start and stop- 2 stops, 2 call stations (key switch servelift-standard, call button)- lower and upper door: - manual door DIN R - automatic door closer - door width approx.: 995x2074mm- heat regulated shaft ventilation- emergency telephone (Amigo) with GSM- battery backup- electrical switchbox RAL 7035 - with heating element- angled roof without lights- lighted emergency shutdown- heating element for the engine- all visible surfaces powder coated RAL???
by customer or Hissipörssi- transport- installation- costs for final inspection
100x100x5mm by customer
250
374
10mmlaminatedglass