Business Network Solutions for Dynamic Computing Services Connection
Commissioning
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 1/14
Contents
1 Preparation ............................................................................................................................................................................. 2
2 DCS Commissioning ............................................................................................................................................................. 3
2.1 Cloud Part – DCS Portal ............................................................................................................................................... 3
2.2 BNS Part – BNS Dashboard ......................................................................................................................................... 5
2.3 Cloud Bonus Part – vCloud Director ......................................................................................................................... 6
3 DCS+ Commissioning ......................................................................................................................................................... 10
3.1 Cloud Part – DCS Portal ............................................................................................................................................. 10
3.2 BNS Part – BNS Dashboard ....................................................................................................................................... 14
3.3 Cloud Bonus Part – vCloud Director ....................................................................................................................... 14
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 2/14
1 Preparation
The following data should be prepared before starting either of the onboarding processes (DCS/DCS+),
to ensure everything runs smoothly. The CP-ID/Key can only be found once the onboarding process has
been started (see chapter 2.2/3.2).
➢ Connection Point Name (EON name)
➢ Network Address (Network address for your EON)
➢ Gateway IP Address (IP for the virtual gateway connected to the EON -> auto-gen rec*)
➢ IP Address Router 1 (auto-gen rec)
➢ IP Address Router 2 (auto-gen rec)
➢ Pool Start IP Address (IP pool for the EON -> auto-gen rec)
➢ Pool End IP Address (IP pool for the EON -> auto-gen rec)
➢ DNS Server 1/2 (optional -> swisscom rec)
➢ DNS Domain (for VM's connected to the EON -> optional)
➢ "Shared" Yes to share the EON in all your Dynamic Data Centers
Connection Point ID/Key (to be used in the BNS dashboard to connect the EON)
ATTENTION:
➔ The desired subnet may not be in use at any other customer location.
➔ The desired subnet must be in the private network range (RFC 1918). If this requirement is
ignored, the packets will not be routed between BNS and DCS.
➔ The connection point cannot be adjusted after it has been created.
*auto-gen rec = auto-generated recommendation from Swisscom
BNS Customer
192.168.100.0/24
192.168.100.1
192.168.100.2
192.168.100.3
192.168.100.100
192.168.100.200
16
193.5.23.1 / 193.247.204.1
16
16
16
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 3/14
2 DCS Commissioning
The first step for ensuring a successful configuration must take place on the DCS side. Using the data
from Chapter 1, a virtual EON (external organizational network) must be configured, which can be
seen on the DCS and should be connected to the BNS router.
2.1 Cloud Part – DCS Portal
Log in to the enterprise extranet using your personal extranet login.
(extranet.swisscom.ch / datacenter.swisscomcloud.com)
Click on the eService "Dynamic Computing" within the DCS portal. The 2-factor authentication is
started.
In the next step, you select the data center via the DCS portal, which is to be connected to BNS. Click
the network symbol of the respective DDC.
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 4/14
Add a "Connection Point" under "Swisscom Cloud Services Connectivity".
Fill in the fields "Connection Point Name" and "Network Address" on the screen that appears. If
required, the automatically generated details can be adjusted (e.g. Pool IP Range / DNS / Shared).
Now click on "Submit Order".
In a few minutes, you will receive an e-mail confirming the successful creation of the EON. After the
order has been completed successfully, the CP-ID will be visible on the DCS portal under "Swisscom
Cloud Services Connectivity" in the Connectivity area of the respective data center under "Info".
The remaining configuration settings will now be entered via the BNS dashboard.
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 5/14
2.2 BNS Part – BNS Dashboard
Log in to the BNS Dashboard via the Partner Extranet. In the BNS Dashboard under the menu point
"Groups", open the menu "Service Connections". IN the drop-down menu choose the stack (DCS or
DCS+). Enter the DCS CP-ID retrieved in 2.1. Attention: For DCS+ the Connection Point Key must be
entered. Inform the customer about the terms and conditions and click the checkbox. Open the
shopping cart and submit the order. The connection should be established within a short period of
time (approx. 15 minutes).
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 6/14
2.3 Cloud Bonus Part – vCloud Director
In the next to last step, you will log on to the extranet again and switch to the DCS portal (see chapter
2.1). This time, however, you go one step further and open the vCloud Director by clicking the server
icon of the respective Data Center.
From the start page, switch to the vApp that has been prepared for this example, for which a VM has
already been commissioned and which is to be connected to BNS (the server must be stopped to
complete the configuration).
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 7/14
Right-click the VM and then select "Properties".
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 8/14
In the "Hardware" menu under "Network adapter", select "Add network..." via the drop-down menu.
On the next screen, select "VDC organization network" and then click "Continue".
Now select the correct BNS network and select "Finish".
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 9/14
Now click "OK" to attach the network. The server can now be started and the configuration tested.
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 10/14
3 DCS+ Commissioning
The first step for ensuring a successful configuration must take place on the DCS side. Using the data
from Chapter 1, a virtual EON (external organizational network) must be configured, which can be
seen on the DCS and should be connected to the BNS router.
3.1 Cloud Part – DCS Portal
First, log in to the ENT extranet using your personal extranet login.
(extranet.swisscom.ch / datacenter.swisscomcloud.com)
Click on the eService "Dynamic Computing+" within the DCS portal.
→ The 2-factor authentication is started.
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 11/14
In the next step, you select the data center via the DCS portal, which is to be connected to BNS. Click
on the respective DDC.
Now click on Actions and "Create Connection Point".
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 12/14
Enter a name for your Connection Point and click on "Next"
Enter the Network Settings you prepared on chapter 1 beforehand (Options like the Pool Start-, and End IP
are changeable). Click "Next".
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 13/14
Click "Submit"
After the order has been completed successfully, you can get the Connection Point Key in the DCS portal.
Click on the Datacenter from where you ordered the Connection Point. Then select "Connection Point"
from the dropdown menu. And after that click on the Connection Point.
Swisscom (Switzerland) Ltd BNS to DCS/DCS+ Connection 14/14
You can copy the Connection Point Key to the second page in this document. Then head on to the next
chapter.
3.2 BNS Part – BNS Dashboard
Follow the same steps as in chapter 2.2.
3.3 Cloud Bonus Part – vCloud Director
Log in to the extranet and switch to the DCS+ portal (see chapter 3.1). This time, however, you go one
step further and open the vCloud Director by clicking on the vCD Icon on the top right corner.
Then follow the steps from point 2.3 after the first image.