62 THERMOZONE AC 300/ WAC 300 Frico AB, Box 102, SE-433 22 Partille Tel: +46 31-336 86 00 Fax: +46 31-26 28 60 [email protected] www.frico.se Design and specifications are subject to change without notice. 0.5 m 1.5 m 2.5 m 3.5 m 6.9 m/s 5.0 m/s 4.1 m/s 10.0 m/s AC 300/WAC300 The Thermozone 300-series consists of the AC variant in both heated and ambient only format and the hot water heated WAC model. These models are designed for permanenet hori- zontal installation over doorways of heights between 2.5 and 3.0 metres or positioned vertically beside the doorway when overdoor space is limited. They can be surface mounted or recessed into a false ceiling. A jet of air from the air curtain prevents cold draughts throught open doorways and increases comfort levels in the proximity of the door whereas the ambient air variant has been specifically designed for cold store applications and entrances to airconditioned buildings to prevent the loss of refrigerated air. The use of a Thermozone 300 air curtain enables the use of floor space close to the doorway and can significantly reduce energy losses giving large savings. The Thermozone 300 range can also be used for industrial heating and drying applications. For wide doorways, several units can be mounted next to each other and regulated with a common thermostat and control panel. The Thermozone 300 series is manufactured in lengths of 1.0 and 1.7 metres which can be combined to best cover a particular doorway. For doorways which are fitted with ceiling mounted sliding doors, adaptation sets are available that direct the airflow close to the opening. Corrosion proof houing made of hot zinc-plate and powder enamelled steel panels. Colour: RAL 9016. Compact design for installation where space is limited. Adjustable mounting brackets for optimisation of air stream. Easy access to connections. Approved by SEMKO and CE compliant Air velocity profile Thermozone AC 300/WAC 300 AIR CURTAINS FOR DOORWAYS BETWEEN 2.5 AND 3.5 METRES Ambient, no heat Hot water heat Electrical heat 8-12 kW Lengths: 1 and 1.7 metres

Transcript of Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71....

Page 1: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

62

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

0.5 m

1.5 m

2.5 m

3.5 m

6.9 m/s

5.0 m/s

4.1 m/s

10.0 m/s

AC 300/WAC300

The Thermozone 300-series consists of the ACvariant in both heated and ambient only format andthe hot water heated WAC model.

These models are designed for permanenet hori-zontal installation over doorways of heights between2.5 and 3.0 metres or positioned vertically beside thedoorway when overdoor space is limited. They can besurface mounted or recessed into a false ceiling. A jetof air from the air curtain prevents cold draughtsthrought open doorways and increases comfort levelsin the proximity of the door whereas the ambient airvariant has been specifically designed for cold storeapplications and entrances to airconditionedbuildings to prevent the loss of refrigerated air.

The use of a Thermozone 300 air curtain enablesthe use of floor space close to the doorway and cansignificantly reduce energy losses giving largesavings. The Thermozone 300 range can also be usedfor industrial heating and drying applications. Forwide doorways, several units can be mounted next toeach other and regulated with a common thermostatand control panel.

The Thermozone 300 series is manufactured inlengths of 1.0 and 1.7 metres which can be combinedto best cover a particular doorway. For doorwayswhich are fitted with ceiling mounted sliding doors,adaptation sets are available that direct the airflowclose to the opening.

� Corrosion proof houing made of hot zinc-plate andpowder enamelled steel panels. Colour: RAL 9016.

� Compact design for installation where space islimited.

� Adjustable mounting brackets for optimisation ofair stream.

� Easy access to connections.

Approved by SEMKO and CE compliant

Air velocity profile

Thermozone® AC 300/WAC 300AIR CURTAINS FOR DOORWAYS BETWEEN 2.5 AND 3.5 METRES

Ambient, no heat

Hot water heat

Electrical heat 8-12 kW

Lengths: 1 and 1.7 metres

Page 2: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

63

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

Thermozone 300 air-curtains are specifically designed toprotect and heat the exposed entrances of shopping mallsand department stores and will perfectly complementautomatic sliding doors and double door entry systems.

This H&M store occupies a prime location in the heart ofStockholm. The use of Thermozone 300 air curtains toreplace doors in an eight-meter wide entrance has enabledunhindered customer access and improved the potential ofthis presitgious site.

Thermozone 300 can bemounted vertically at theside of an entrancedoorway and shielded fromshopping carts or smallertrucks using an optionalbarrier. With the telescopehood between the topmostunit and the ceiling, and acovering hoop between theunits, you get anaesthetically pleasinginstal lat ion.

At the Golden GateVIP entrance, at theStockholm GlobeArena, the red carpet isalways rolled out.Every measure hasbeen taken to ensurethat guests feel a littleextra welcome,including twoThermozone AC300units to ensure that thewelcome is alwayswarm.

Smaller industrydoors are effectivelyprotected by aThermozone AC/WAC300. A pleasantand draught-freeworking environmentcan be maintainedeven when the doorsare frequentlyopened.

At a loading bay, doors areoften open for prolongedperiods. Cold draughts canthen significantly effect theinternal temperature.Thermozone 300 is anexcellent complement togaiters in counteractingdraughts and saving energy.

Page 3: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

64

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

Thermozone AC 300 without heat

Type Output stages Air flow Sound level Voltage Amperage Length Weight[kW] [m3/h] [dB(A)] [V] [A] [mm] [kg]

AC301 0/ 900/1800 44/62 230V~ 1 .6 1000 3 9

AC302 0/ 1300/2700 45/63 230V~ 2 .5 1670 5 7

Protection class AC300 without heat: (IP24), splash-proof design.

Thermozone AC 300 with electrical heating

Type Output stages Air flow Dt * 1 Sound level Voltage [V] Voltage[V] Length Weight[kW] [m3/h] [°C] [dB(A)] Amperage[A] Amperage[A] [mm] [kg]

(control) (heat)

AC308 0/ /4/8 900/1800 27/13 44/62 230V~/1 .6A 400V3~/11 .6A 1000 4 4

AC312 0/ /6/12 1300/2700 27/13 45/63 230V~/2 .5A 400V3~/17 .3A 1670 6 4

*1) ∆t = temperature rise of passing air at maximum heat output and lowest/highest air flow.

Protection class AC 300 with electrical heating: (IP24), splash-proof design.

Thermozone WAC 300 with hot water heating

Type Air flow Water volume Sound level Voltage Amperage Length Weight[m3/h] [l] [dB(A)] [V] [A] [mm] [kg]

WAC301 800/1700 2 .5 44/62 230V~ 1 .6 1000 5 1

WAC302 1200/2500 3 .5 45/63 230V~ 2 .5 1670 7 4

WAC301V 800/1700 2 .5 44/62 230V~ 1 .6 1000 5 1

WAC302V 1200/2500 3 .5 45/63 230V~ 2 .5 1670 7 4

For vertical mounting: WAC301V and WAC302V.Protection class WAC300, with hot water heating: (IP24), splash-proof design.For information on heat output, see output charts on page 71.WAC301, WAC302 are approved by SEMKO and CE compliant.WAC301V, WAC302V are CE compliant.

TECHNICAL SPECIFICATIONS

Page 4: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

65

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

985 / 1670

975 / 1640640

400

360

Thermozone AC 300

580

400490

335

ø 11

ø 20

POSITIONING, MOUNTING AND INSTALLATION

Different unit lengthsensures coverage of all doorwidth.

Installaton in false ceiling.

DIMENSIONS

Mounting above doorwayWith the supplied mounting consoles, ThermozoneAC/WAC300 units may be fitted in several ways: onthe wall, on the ceiling, on a cable ladder, etc. Theconsoles make it possible to angle the unit for optimalefficiency. They can also be mounted in false ceilings,see sketch nr 2. Among the hot water heated models,WAC301 and WAC302 are mounted in horizontalpostion above the opening. For minimum mountingdistance to doorway, see sketch nr 1 for theelectrically heated models. The units must not bemounted directly below a power point. For maximumperformance the units should cover the whole widthof the opening and be fitted as close to the openingas possible. Several units can be mounted next toeach other to form a continuous air curtain.

Mounting below ceiling-mounted sliding doorsWhen mounting above openings with ceiling-mounted sliding doors, a square-shaped air curtain

Two towers of verticallymounted, with sideblowingunits.

unit cannot be positioned close enough to theopening because of the opening radius of the slidingdoor. The adaption set AXT401/402 is dome-shapedand may therefore be positioned up against the doorwith the outgoing air stream very close to theopening.

Mounting at the side of the openingWhen space above the doorway is limited, modelsWAC301V and WAC302V can be mounted vertically,thus creating a side blowing air stream. Mountingplates AVMP300 are mounted between units andbetween the lowest unit and the floor. For minimummounting distance to doorway, see sketch nr 1 for theelectrically heated models. For maximum performancethe units should cover the whole height of theopening and be fitted as close to the opening aspossible. Several units can be mounted on top of eachother to form a continuous air curtain. Maximumbuilding height for vertical units without structuralsupport, is 3.5 metres.

Page 5: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

66

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

490

min 300

580

Thermozone AC 300

35 30 35430 1070

1120

945

Connection DN20 (¾�)Inside thread

Sketch 2: Mounting in false ceiling

Sketch 3: WAC300, water connection on the top side to theright

Sketch 1: Minimum distance to wall 300 mm

Connection AC 300 The appliance should be preceded by a triple poleswitch with at least 3 mm breaking gap. Theconnection should be made with a cable type S05VV-U, A05VV-R or similar, through knock outs on the topside of the unit (2 x ø38 mm and 3 x ø29 mm). Forconnection to the supply terminal block, a cable ofmaximum 16 mm2 is used. For connection to thecontrol terminal block, a cable of maximum 6 mm2 isused. For units with electrical heating, power andvoltage should be supplied in different connectionareas. See wiring diagram at page 74-76.

Connection WAC 300 The appliance should be preceded by a triple poleswitch with at least 3 mm breaking gap. Theconnection should be made with a cable type S05VV-U, A05VV-R or similar, through ø29 mm knock outs onthe top side of the unit. For connection to the controlterminal block, a cable of maximum 6 mm2 is used.Connections (DN20 (3/4�), inside thread) to the waterheating coil are located on the top of the unit. Seesketch 3 and wiring diagrams at page 76-77. Thesupplied 0.8 metre flexible hoses, permit the unit to betilted.

Sketch 4: Adaptation set AXT401/402

Page 6: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

67

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

REGULATION ALTERNATIVES

Air curtains without heat :Fan speed regulationWhen the gate opens and closes, the position limitswitch signals on and off. When on, the fan speed isregulated with a suitable fan speed regulator.

Complete regulation kit:� AGB304, position limit switch� ACR304, 4-stage regulator or

ACR3042, 4-stage regulator high/low speed orACR3042T1, 4-stage regulator high/low speedwith time relay or2221AG, variable fan speed regulator

Air curtains with electrical heating :Fan speed and thermostat regulation with positionlimit switchWhen the gate opens and closes, the position limitswitch signals on and off. When on, the fan speed isregulated with a suitable fan speed regulator. The2-stage room thermostat controls the heat supply intwo stages (0, 1/2, 1/1). The output may be manuallycontrolled with an output selector.

Complete regulation kit:� AGB304, position limit switch� ACR304, 4-stage regulator or

ACR3042, 4-stage regulator high/low speed orACR3042T1, 4-stage regulator high/low speedwith time relay orFRE6, digital variable fan speed regulator

� KRT2800, 2-stage thermostat orRTI2, electronic 2-stage thermostat

� EV300, output selector

ACCESSORIES

RTI2, electronic 2-stage thermostat Regulates the heat. Adjustable temperature differencebetween the stages (1�10°C). Setting range 5�35°C.For electrically heated air curtains (AC308, AC312).Protection class: splash-proof design (IP44).

RTE102, electronic thermostat Opens/closes water valves and starts/stops fans.Internal temperature setting 7�35°C. Delivered withcovering frame. Used with electrically heated aircurtains (WAC301, WAC302, WAC301V, WAC302V).Protection class: normal design (IP30).

For further alternatives: see section on Thermostats.

KRT2800, 2-stage thermostat Regulates the heat. Adjustable temperature differencebetween the stages (1� 4°C). Setting range 0�40°C.For electrically heated air curtains (AC308, AC312)Protection class: jet-proof design (IP55).

KRT1900, capillary tube thermostat Opens/closes water valves and starts/stops fans. Athermostat with alternating relay for control of heatand fans. For hot water heated air curtains (WAC301,WAC302, WAC301V, WAC302V). Protection class: jet-proof design (IP55).

KRT1900/2800 RTE102RTI2

Air curtains with hot water heating :Fan speed and thermostat regulation with positionlimit switchWhen the gate opens and closes, the position limitswitch signals on and off. When on, the fan speed isregulated with a suitable fan speed regulator. Theheat supply is controlled by thermostat and by a setof valves. The output may be manually controlledwith an output selector.

Complete regulation kit:� AGB304, position limit switch� ACR304, 4-stage regulator or

ACR3042, 4-stage regulator high/low speed orACR3042T1, 4-stage regulator high/low speedwith time relay or2221AG, variable fan speed regulator orFRE6, digital variable fan speed regulator

� KRT1900, capillary tube thermostat orRTE102, electronic thermostat

� VR20/25, valve set orTVV20/25, valve and SD20, actuator

Page 7: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

68

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

AGB304, position limit switchStarts the air curtain or activates a fan speed regula-tor when the door opens. When the door closes, itshuts the air curtain off or signals to the regulator.

ACR304, 4-stage regulator With ACR304, the fan speed can be adjusted in 4stages to achieve optimal performance and protectionat different door heights. The fan is turned off whenthe door closes. The regulator controls a maximum of5�7 units. Max input 14 A. Protection class: splash-proof design (IP 44).

ACR3042, 4-stage regulator high/low speed With ACR3042, the fan speed can be adjusted in 4stages to achieve optimal performance and protectionat different door heights. One speed is selected forwhen the gate is open and a lower speed is selectedfor when the gate is closed. The regulator controls amaximum of 5�7 units. Max input 14 A. Protectionclass: splash-proof design (IP 44).

ACR3042T1, 4-stage regulator

high/low speed with time relay With ACR3042T1, the fan speed can be adjusted in 4stages to achieve optimal performance and protectionat different door heights. One speed is selected forwhen the gate is open and a lower speed is selectedfor when the gate is closed. ACR3042T1 is equippedwith a time relay. When the gate is closed, the fan willremain at the selected speed for a desired period. Thisfunction is particularly useful when a gate isfrequently opened and closed. The regulator controlsa maximum of 5�7 units. Max input 14 A. Protectionclass: splash-proof design (IP 44).

2221AG, Variable fan speed regulator Single-phase thyristor for variable fan speed controland for switching off and on. For surface mounting.Fits in rectangular mounting case. The regulatorcontrols a maximum of 2�3 units. Max input 5 A. Itregulates hot water heated units (WAC301, WAC302,WAC301V, WAC302V) and units without heat (AC301,AC302). Protection class: splash-proof design (IP 44).

FRE6, digital variable fan speed regulator The FRE6 has two different regulation programs tocontrol the air curtain. The UT-regulation that iscontrolled by the door contact, room thermostat andthe outdoor temperature - and the IT-regulation thatis controlled by the door automation. Regulates amaximum of 1-3 units. Max input 6 A. A slave unitmust be used with amperage above 6 A . FRE6regulates hot water heated units (WAC301, WAC302,WAC301V, WAC302V) and electrically heated units(AC308, AC312). Protection class: splash-proofdesign (IP 54).

EV300, output selector Electrically heated units (AC308, AC312) can becontrolled with the output selector EV300. Outputstages: 0�1/2�1/1. Protection class: splash-proofdesign (IP 44).

AGB304 ACR304 2221AG FRE6ACR3042 / ACR3042T1 EV300

Page 8: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

69

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

VR 20/25, valve set For regulation of water flow to hot water heatedair curtains.

The valve set consists of the following:� AV20/25, stop valve� JV20/25, adjustment valve� TRV20/25, on/off 3-way motor valve� BPV10, by-pass valve� SD20, actuator on/off 230V~

The stop valve (AV20/25) consists of a ball valvewhich is either open or closed. It is used to turn thewater flow off and on. The water flow can be fine-tuned manually with the adjustment valve (JV20/25).It can also be completely turned off. Through apressure outlet the flow can be measured. The kvvalue for JV20 is 0,13�5,9 and for JV25 0,17� 8,52.The 3-way motor valve (TRV20/25) consists of anactuator and a housing. When the TRV20/25 isclosed, the flow through the by-pass valve is low toensure presence of hot water in the heating coil. Thisleads to instant heat supply when needed and somedegree of frost protection. Actuator SD20 works on/off.

The valve set is available with two different valvedimensions: VR 20 - DN20 (3/4�) and VR 25 - DN25(1�). The by-pass valve dimension is DN10 (3/8�). Toregulate VR20/25, a suitable thermostat has to beadded.

TVV20/25, 2-way regulation valve TVV20 has a pipe dimension of DN20 (3/4�) andTVV25 of DN25 (1�). Pressure class PN16. Maximumpressure 2 MPa (20 bar).Maximum pressure fall TVV20: 100 kPa (0,1 bar)Maximum pressure fall TVV25: 62 kPa (0,062 bar)The kv-value is adjustable in 3 stages:

SD20, actuator on/off 230V~ SD20 regulates the heating. Works on/off. A 5 secondclosing of the valves prevents sudden pressurechanges in the pipe system. (IP40).

TVV20/25, 2-way regulation valve and SD20, actuatorprovide a basic form of water regulation without thepossibility of adjusting or shutting the water flow off.A suitable thermostat is choosen to regulate TVV20/25 and SD20.

Pos. 1 Pos. 2 Pos. 3

TVV20 kv 1,6 kv 2,5 kv 3,5

TVV25 kv 2,5 kv 4,0 kv 5,5

SD20JV20/25 TVV20/25AV20/25

TRV20/25 BPV10

TVV20/25

SD20

KRT, RTE

BPV10

AV20/25

JV20/25

TVR20/25

KRT

VR

20

/25

SD20

230V ~230V ~

C̊ C̊

Thermozone AC 300 Thermozone AC 300

Page 9: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

70

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

Type Description HxWxD[mm]

KRT2800 2-stage thermostat 165x60x57

KRT1900 Capillary tube thermostat 165x60x57

RTI2 Electronic 2-stage thermostat 150x80x50

RTE102 Electronic thermostat 71x71x28

ABG304 Position limit switch

ACR304 4-stage regulator 100x80x90

ACR3042 4-stage regulator high/low speed 213x155x110

ACR3042T1 4-stage regulator high/low speed with time relay 213x155x110

2221AG Variable fan speed regulator 170x85x63

FRE6 Digital variable fan speed regulator 180x210x110

EV300 Output selector 100x80x90

VR20 Valve set, connection DN20

VR25 Valve set, connection DN25

TVV20 2-way valve, connection DN20

TVV25 2-way valve, connection DN25

SD20 Actuator on/off

22003 False ceiling grille 1192x192

22004 False ceiling grille 1515x192

AVMP300 Mounting plates

AXT401 Adaptation set for ceiling-mounted sliding doors 1000

AXT402 Adaptation set for ceiling-mounted sliding doors 1670

AXP300 Collision protection

AXB300 Covering hoop

AXH300 Telescope hood

22003 and 22004, false ceiling grillesThere are false ceiling grilles for air intake anddischarge available for mounting the air curtain infalse ceiling systems. Available in 2 sizes.

AVMP300, mounting platesWhen the units are mounted in a standing position atthe side of the door, mounting plates are fittedbetween units and between the lowest unit and thefloor. The mounting plate consists of two parts. Theouter one is secured in the floor or at the top of thelower unit. The inner part is mounted on the underside of the unit that is standing on the floor.

AXP300, collision protectionAXP300 is mounted on the ground next to a standingair curtain unit to prevent it from being hit by trucks,shopping trolleys and similar.

AXB300, covering hoopThe hoop is fitted between standing units to coverthe joint and provide a neat installation.

AXH300, telescope hoodVertically adjustable (between 50 mm and 110 mm). Itis used to cover the space between the ceiling andthe top unit of a vertical installation.

22003/22004 AVMP300 AXP300 AXB300 AXH300AXT401/402

AXT401/402, adaptation setWhen mounting above openings with ceiling-mounted sliding doors, mounting kits are availablethat position the outgoing air stream close to theopening.

Page 10: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

71

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

OUTPUT CHARTS WATER

Incoming / outgoing water temperature 80/60°CIncoming air temp. = +15°C Incoming air temp. = +20°C

Type Fan Air Output Outgoing Water- Output Outgoing. Water-position flow air temp. flow air temp. flow

[m3/h] [kW] [°C] [l/s] [kW] [°C] [l/s]

WAC301 max 1700 20.5 50.5 0.24 18.5 52.2 0.22

m i n 800 12.2 59.9 0.14 11.1 60.7 0.13

WAC302 max 2500 32.4 53.2 0.38 29.4 54.6 0.35

m i n 1200 19.2 62.6 0.22 17.5 63.0 0.20

WAC301V max 1700 19.1 48.1 0.22 17.2 49.9 0.20

m i n 800 11.5 57.4 0.13 10.4 58.5 0.12

WAC302V max 2500 29.1 49.3 0.34 26.3 51.0 0.31

m i n 1200 17.6 58.4 0.21 16.0 59.3 0.19

Incoming / outgoing water temperature 60/40°CIncoming air temp. = +15°C Incoming air temp. = +20°C

Type Fan Air Output Outgoing Water- Output Outgoing. Water-position flow air temp. flow air temp. flow

[m3/h] [kW] [°C] [l/s] [kW] [°C] [l/s]

WAC301 max 1700 12.4 36.5 0.14 10.4 38.0 0.12

m i n 800 7.5 42.7 0.08 6.3 43.4 0.07

WAC302 max 2500 19.8 38.3 0.23 16.7 39.6 0.19

m i n 1200 12.0 44.4 0.14 10.2 45.0 0.12

WAC301V max 1700 11.5 34.9 0.13 9.6 36.7 0.11

m i n 800 7.1 41.0 0.08 6.0 42.0 0.07

WAC302V max 2500 17.3 35.5 0.20 14.5 37.1 0.17

min 1200 10.3 41.4 0.12 9.1 42.3 0.10

Incoming / outgoing water temperature 60/30°CIncoming air temp. = +15°C Incoming air temp. = +20°C

Type Fan Air Output Outgoing Water- Output Outgoing. Water-position flow air temp. flow air temp. flow

[m3/h] [kW] [°C] [l/s] [kW] [°C] [l/s]

WAC301 max 1700 9.3 31.1 0.07 7.1 32.2 0.05

m i n 800 5.8 36.5 0.04 4.5 36.6 0.03

WAC302 max 2500 15.1 32.8 0.12 11.6 33.7 0.09

m i n 1200 9.5 38.3 0.07 7.4 38.2 0.05

WAC301V max 1700 8.5 29.8 0.06 6.5 31.2 0.05

m i n 800 5.4 35.0 0.04 4.2 35.5 0.03

WAC302V max 2500 12.7 30.0 0.10 9.6 31.3 0.07

m i n 1200 8.2 35.1 0.06 6.3 35.4 0.04

Incoming / outgoing water temperature 55/35°CIncoming air temp. = +15°C Incoming air temp. = +20°C

Type Fan Air Output Outgoing Water- Output Outgoing. Water-position flow air temp. flow air temp. flow

[m3/h] [kW] [°C] [l/s] [kW] [°C] [l/s]

WAC301 max 1700 10.3 32.9 0.12 8.3 34.3 0.09

m i n 800 6.3 38.2 0.07 5.1 38.9 0.06

WAC302 max 2500 16.5 34.5 0.19 13.4 35.8 0.15

m i n 1200 10.1 39.8 0.12 8.3 40.3 0.09

WAC301V max 1700 9.5 31.5 0.11 7.6 33.2 0.09

m i n 800 5.9 36.8 0.07 4.8 37.7 0.05

WAC302V max 2500 14.4 31.9 0.17 11.5 33.5 0.13

m i n 1200 9.0 37.1 0.10 7.3 37.8 0.08

Page 11: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

72

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

V V

WAC

301

WAC

302

WAC

301V

WAC

302V

0.01 0.1 1.0

1 0

7 0

1

0.1 1.0 1 0

0.1

0.7

0.01

7 0

0.1 1.0 1 0

0.7

0.01 0.1 1.0

1 0

1

0.1

0.01

Water pressure drop over WAC 300 water coil

Water pressure drop over regulations and valves

Pre

ssur

e dr

op [

kPa]

Pre

ssur

e dr

op [

bar]

PRESSURE DROP WATER

Water flow [m3/h]

Water flow [l/s]

Water flow [m3/h]

Pre

ssur

e dr

op [

kPa]

Pre

ssur

e dr

op [

bar]

Water flow [l/s]

The pressure drop is calculated for an average temperature of 70°C (PVV 80/60).

For other water temperatures, the pressure drop is multiplied with the factor K.

Average temp. water °C 4 0 5 0 6 0 7 0 8 0 9 0

K 1.10 1.06 1.03 1.00 0.97 0.93

Page 12: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

73

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

~N

1 2 3 4

NP 1 2 3 4

NP

L1 N (L2)230 V~

~N

1 2 3 4

NP 1 2 3 4

NP

L1 N (L2)230 V~

AC301�302

AC301�302

AGB304

AC301�302

AC301�302

4321

1 3 5 70

XXX

X

X

XXXX

321 4 5 6 7 8 9NP

NL

L1 N (L2)230 V~

M~ c̊ M~ c̊ M~ c̊

NL L

PTC

2 6 8

1 5 73

AC/WAC300

ACR304AGB304

WIRING DIAGRAMS AC301 AND AC302

Variable fan speed adjustment with thyristor2221AG

Variable fan speed adjustment with thyristor2221AG, start/stop with position limit switchAGB304

Manual 4-stage fan speed regulation with ACR304, start/stop with position limit switch AGB304

AGB304,position limit switch

2221AG,variable fanspeed regulator

2221AG,variable fanspeed regulator

ACR304,4-stage regulator

AGB304,position limit switch

2221AG

2221AG

Max input for the variable fan speed regulator2221AG is 5A. It regulates 3 x AC301 or 2 xAC302.

AC/WAC300

Page 13: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

74

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

NP 1 2 3 4 5 6 7

4 5 6

10 12 13 14

10 12 13 14

5 1

6 2

L1 L2 L3

400V3~/230V3~

L1 L2 L3

400V3~/230V3~

L1 N (L2)230 V~

L1 N (L2)230 V~

NP1 2 3 4 65 7

Hi Lo4321

1 3 5 70

XXX

X

X

XXXX

2 6 8

1 5 73

ACR304

EV300

RTI2

AC308/312

AGB304

321 4 5 6 7 8 9NP

NL

L1 N (L2)230 V~

400V 3~/230V 3~

M~ c̊ M~ c̊ M~ c̊

NL L

PTC

4321

1 3 5 70

XXX

X

X

XXXX

230 V3~

123

Hi

Lo

Diff (1-4)K

123

5 1

6 2

6 2O

XX

X

L1 L2 L313 14121110

400 V3~

K2K2

2 6 8

1 5 73

ACR304 EV300

KRT2800

AC308/312

AGB304

AC308/312

Manual 4-stage fan speed regulation with ACR304, start/stop with position limit switch AGB304, automatic2-stage heat regulation with thermostat RTI2, output selection 0�½�1 output with EV300

ACR304,4-stage

regulator

AGB304,position limit

switch

EV300,output selector

WIRING DIAGRAMS AC308 AND AC312

Manual 4-stage fan speed regulation with ACR304, start/stop with position limit switch AGB304, automatic2-stage heat regulation with thermostat KRT2800, output selection 0�½�1 output with EV300

EV300,output selector

KRT2800,2-stage thermostat

ACR304,4-stage

regulator

AGB304,position limit

switch

AC308/312

RTI2,electronic2-stagethermostat

AC308/312

Page 14: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

75

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

NP 1 2 3 4 5 6 7

4 5 6

10 12 13 14

10 12 13 14

5 1

6 2

L1 L2 L3

400V3~/230V3~

L1 L2 L3

400V3~/230V3~

L1 N (L2)230 V~

L1 N (L2)230 V~

NP1 2 3 4 65 7

Hi Lo3132 33 34 35 36 37 38

1 2 3 4

X

X

X

X

X

X

X

XX

AGB304

ACR3042

EV300

RTI2

AC308 /312

AC308 /312

NP 1 2 3 4 5 6 7

3132 33 34 35 36 37 38

4 5 6

10 12 13 14

10 12 13 14

1 2 3 4

X

X

X

X

X

X

X

XX

123

Hi

Lo

Diff (1-4)K

123

5 1

6 2

L1 L2 L3

400V3~/230V3~

L1 L2 L3

400V3~/230V3~

L1 N (L2)230 V~

6 2O

XX

X

AGB304

ACR3042

EV300

KRT2800

AC308/312

AC308/312

WIRING DIAGRAMS AC308 AND AC312

High/low fan speed with position limit switch AGB304 and ACR3042, automatic 2-stage heat regulationwith thermostat RTI2s, output selection 0�½�1 output with EV300

RTI2,electronic2-stage thermostat

ACR3042,4-stage regulator

AGB304,position limit

switch

EV300,output selector

High/low fan speed with position limit switch AGB304 and ACR3042, automatic 2-stage heat regulationwith thermostat KRT2800, output selection 0�½�1 output with EV300

ACR3042,4-stage

regulator

AGB304,position limit

switch

EV300,outputselector

KRT2800,2-stagethermostat

AC308/312

AC308/312

Page 15: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

76

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

NP 1 2 3 4 5 6 9

230 V~

NL N U 1 2TK 5 6 101112TK 21222324

NP 1 2 3 4 5 6 9

21

3c̊

TRV/TVV

SD20

NP 1 2 3 4 5 6 7

230 V~

10 12 13 14 L1 L2 L3

400V3~/230V3~

NL N U 1 2TK 5 6 101112TK 21222324

51

62

8 9

6 2O

XX

X

NL 1 2

NP 1 2 3 4 5 6 7 10 12 13 14 L1 L2 L3

400V3~/230V3~

8 9

21

3c̊

WAC301-WAC302V

EV300

FRE6

FRE6

WAC301-WAC302V

AC308/AC312

AC308/AC312

WIRING DIAGRAMS WAC301, WAC301V, WAC302 AND WAC302V

WIRING DIAGRAMS AC308 AND AC312

Outdoor compensated variable fan speed regulation with FRE6

SD20, actuator, on/off, 230V~

TRV/TVV20/25

Outdoor compensated variable fan speed regulation with FRE6, effect limitation with output selectorEV300 in effect stages 0-½-1.

Outdoorsensor

Roomthermostat

Door contact

Outdoorsensor

Roomthermostat

Door contact

AC308-AC312

EV300,output selector

FRE6,dig i ta l

variable fan speedregulator

WAC301(V)/302(V)

FRE6,dig i ta l

variable fan speedregulator

WAC301(V)/302(V)

FRE6 regulates a maximum of 4 x AC308 or 2 xAC312.

FRE6 regulates a maximum of 4 xWAC301(V) eller 2 x WAC302(V)

Page 16: Thermozone AC 300/WAC 300 - Ekosal · For information on heat output, see output charts on page 71. WAC301, WAC302 are approved by SEMKO and CE compliant. WAC301V, WAC302V are CE

77

THERMOZONE AC 300/ WAC 300

Frico AB, Box 102, SE-433 22 Partille � Tel: +46 31-336 86 00 � Fax: +46 31-26 28 60 � [email protected] � www.frico.seDesign and specifications are subject to change without notice.

NP 1 2 3 4 5 6 9

3132 33 34 35 36 37 38

4 5 6 9

1 2 3 4

X

X

X

X

X

X

X

XX

123

12345

L1

230 V~N (L2)

123

12345

4321

1 3 5 70

XXX

X

X

XXXX

321 4 5 6 7 8 9NP

NL

L1 N (L2)230 V~

M~ c̊ M~ c̊ M~ c̊

NL L

PTC

2 6 8

1 5 73

SD20

TRV/TVV

KRT1900

RTE102

ACR304

AGB304

SD20

TRV/TVV

RTE102

KRT1900

WAC301-WAC302V

WAC301-WAC302V

ACR3042

WAC301-WAC302V

AGB304

WIRING DIAGRAMS WAC301, WAC301V, WAC302 AND WAC302V

Manual 4-stage fan speed regulation with ACR304, start/stop with position limit switch AGB304, automaticheat regulation with thermostat RTE/KRT, actuator SD20 and valve TVV20/25

High/low fan speed with position limit switch AGB304 and ACR3042, automatic heat regulation withthermostat RTE/KRT, actuator SD20 and valve TVV20/25

For variable fan speedcontrol, see wiringdiagrams on page 73.

KRT1900,capillary tube

thermostat

RTE102,electronicthermostat

TRV/TVV20/25

SD20, actuator, on/off, 230V~

ACR304,4-stage regulator

ACR3042,4-stage regulator

AGB304,position limitswitch

KRT1900,capillary tube

thermostat

RTE102,electronicthermostat

TRV/TVV20/25,

SD20, actuator, on/off, 230V~

AGB304,position limitswitch

WAC301(V)/302(V)

WAC301(V)/302(V)