Daikin EKHWCH-PB Manual

4
~230 V / 2 kW L=1420 mm ~230/400 V / 2,4,6 kW L=1420 mm ~230/400 V / 2,4,6 kW L=1100 mm EHS/500/1 16 51 31 EHS/500/5 16 51 35 EHS/500/6 16 51 36 03/2017 EHS/500/1 EHS/500/5 EHS/500/6 L  Warnung: Lebensgefahr durch Hochspannung!  Warning: Danger to life - high voltage!  vvertenza: A Pericolo di morte per alta tensione!  Avertissement: Danger de mort - Haute tension!  Waarschuwing: Levensgevaar door hoogspanning!  Advertencia: Peligro de muerte por alta tensión! DE GB IT FR BE ES  Vor Öffnen alle Stromkreise spannungsfrei schalten.  Before opening switch off all voltage circuits.  Prima di aprire i circuiti elettrici togliere la tensione.  Mettre hors tension tous les circuits électriques avant ouverture.  Voor het openen, alle stroomkringen spanningsvrij maken.  Desconectar todos los circuitos de la alimentación eléctrica antes de abrir. DE GB IT FR BE ES !

Transcript of Daikin EKHWCH-PB Manual

Page 1: Daikin EKHWCH-PB Manual

~230 V / 2 kW L=1420 mm

~230/400 V / 2,4,6 kW L=1420 mm

~230/400 V / 2,4,6 kW L=1100 mm

EHS/500/1 16 51 31

EHS/500/5 16 51 35

EHS/500/6 16 51 36

03/2017

EHS/500/1EHS/500/5EHS/500/6

L

  Warnung: Lebensgefahr durch Hochspannung!   Warning: Danger to life - high voltage!  vvertenza:A Pericolo di morte per alta tensione!  Avertissement: Danger de mort - Haute tension!  Waarschuwing: Levensgevaar door hoogspanning!  Advertencia: Peligro de muerte por alta tensión!

DE

GB

IT

FR

BE

ES

  Vor Öffnen alle Stromkreise spannungsfrei schalten.  Before opening switch off all voltage circuits.  Prima di aprire i circuiti elettrici togliere la tensione.  Mettre hors tension tous les circuits électriques avant ouverture.  Voor het openen, alle stroomkringen spanningsvrij maken.  Desconectar todos los circuitos de la alimentación eléctrica antes de abrir.

DE

GB

IT

FR

BE

ES

!

Page 2: Daikin EKHWCH-PB Manual

3 ~400V / 50Hz 6000 W

4+5D+E+F

3 ~230V / 50Hz 6000 W

A+B, C+D, E+F

K2

TR/STB

K1

L1 L2 L3

L1

L2L3

max. 10 Nm

[EHS500x]. .KA EHS500x 03/2017 008.16 316 99_002

[EHS500x]

H O2

A

D

C

B

A

B

C

D

~4-18°C

~78°C

~55°C

X

1.

2.6.

3.

≤1400

≤1150

L [mm]

1420

1100

X [mm]

9

10

11

4. 5.

EHS/500/5 + EHS/500/6

II

K2

TR/STB

K1

L1 L2 L3 N

L1

L2

L3

N

I

Page 3: Daikin EKHWCH-PB Manual

3

[EHS500x]

[EHS500x]. .KA EHS500x 03/2017 008.16 316 99_00

1 ~230V / 50Hz

6000 W

1+2+3, 4+5

D+E+F

EHS/500/5 + EHS/500/6

III

K2

TR/STB

K1

L1 N

1.

N

A

B

C

D

E

F

L1

K1K2

TR

N L

RCD (FI)

Fuse 16APower surgecategory

(1 ~230V / 50 Hz)

3x 2,5 mm²

3.

2.

5.6.

4.

STB

Page 4: Daikin EKHWCH-PB Manual

L1N E1H

Q1LTR+STBQ1L

EHSEHS

K1230V / 50HzHT / NT

NYM230V≥2,5 mm²

Affectation des broches EHS/500/1(France seulement)

~3000 mm

TR+STB

~230V / 50Hz

2000 W

L1 N

~230 V,50 Hz

FR

R

OT

EX

· K

A E

HS

500x

· Irr

tum

und tech

nis

che Ä

nderu

ngen v

orb

ehalte

n / S

ubje

ct to c

hange a

nd c

orr

ect

ion ·

008.1

6 3

16 9

9_00 ·

03/2

017

www.rotex-heating.com

www.daikineurope.com

EHS/500/1

E1H Chauffage d'appointEHS Résistance électrique / Booster-HeaterF1B Fusible électrique (16 A, 230 V)F2B Fusible électrique (16 A, 230 V)K1 Bornier 1NYM Câblage rigideQ1DI Mise à la terreQ1L Régulateur de températureSTB Limiteur de température de sécurité (LTS)TR Régulateur de température

[EHS500x]